background image

5.5

 

Setting The DMX Address 

 

  The DMX FX-

15™ can be addressed to any DMX channel from 1 to 511. 

  The DMX FX-

15™ occupies just one channel of DMX to operate. 

  The DMX FX-

15™ Switch Pack will not operate when all nine dip switches are in the 

“OFF” position. 

 

DMX Address = The added value o

f all the dip switches in the “ON” position 

 

 

DMX CHANNEL: 1 = 1 

 

DMX CHANNEL: 12 = 4 + 8 

 

DMX CHANNEL: 173 = 1 + 4 + 8 + 32 + 128 

 

DMX CHANNEL: 482 = 2 + 32 + 64 + 128 + 256 

 

 

5.6

 

Operation 

 

  With all of the DMX and power cables properly connected and DMX addressed, you 

may switch the DMX FX-

15™ Switch Pack on by increasing the value of the assigned 

DMX channel to 128-255 (50%-100%). 

  Decrease the value of the assigned DMX channel to 0-127 (0%-49%) to turn the DMX 

FX-

15™ Switch Pack off. 

  If for any reason the DMX signal is lost (e.g. the DMX console is turned off), the DMX 

FX-

15™ Switch Pack will turn off the power to the attached device. 

 

It is always recommended to use a DMX line terminator at the end of your DMX run to 
soak up any residual DMX signal.

 

 

 

 

5.7

 

Indicator Lights (LED) 

 

  RED / POWER: 

o

 

ON:

  Line voltage present. 

Summary of Contents for DMX FX-15 205052

Page 1: ...DMX FX 15TM SWITCH PACK Operating Instructions P N 250051 120V P N 205052 230V...

Page 2: ...sure proper operation of this unit please take some time to read the manual carefully We believe you will enjoy years of great service if you properly care for your new DMX FX 15 Switch Pack CITC 1420...

Page 3: ...erating the DMX FX 15 Switch Pack 5 1 Selecting The Location 5 2 Electrical Power Requirements 5 3 Hooking Things Up 5 4 Parts Location 5 5 Setting The DMX Address 5 6 Operation 5 7 Indicator Lights L...

Page 4: ...uge o 230V 16 Gauge Instruction Booklet Warranty Card Universal Plug Adapter 230V Only 2 Accessories Hanging Bracket w Safety Cable C Clamp DMX Cables Spare Fuses Please check whether all the products...

Page 5: ...oubts about the capacity or grounding of your existing circuits consult a qualified electrician o Do not operate or store in wet locations 5 Operating the DMX FX 15 Switch Pack 5 1 Selecting The Locat...

Page 6: ...5 1 DMX OUT FEMALE 5 PIN DMX XLR 2 DMX IN MALE 5 PIN DMX XLR 3 DMX ADDRESS DIP SWITCHES 4 POWER OUT 3 PRONG OUTLET 5 FUSE HOLDER 6 POWER IN IEC MALE OUTLET 7 INDICATOR LIGHTS LED...

Page 7: ...eration With all of the DMX and power cables properly connected and DMX addressed you may switch the DMX FX 15 Switch Pack on by increasing the value of the assigned DMX channel to 128 255 50 100 Decr...

Page 8: ...nated but no Relay light Check DMX address The value of the assigned DMX channel must be 128 255 50 100 to operate 6 Technical Data 7 Limited Warranty Conditions 1 Subject to the following conditions...

Page 9: ...the machine any faults and damages caused by undue force will lead to a loss of limited warranty 4 Freight costs to CITC when under the limited warranty services are the responsibility of the customer...

Page 10: ...r Limited Warranty Send unit to CITC RMA XXXXXXX 1420 80th St SW D Everett WA 98203 Tel 888 786 CITC or 425 776 4950 Fax 425 776 5129 Website www citcfx com E mail info citcfx com 1420 80th St SW Ever...