activating the 12 hour hygiene cycle

Enter into confi guration mode. Point the ICU at the 

sensazone

 and press the 

5

: The sensor blinks green once.

Pressing the

and

buttons switches the hygiene cycle 

function on or off respectively. Press the 

 button to verify 

the setting; the sensor displays the current setting by 
fl ashing green.

Single fl ash:

 hygiene cycle OFF

Double fl ash:

 hygiene cycle ON

Save setting and exit ICU confi guration mode by pressing 
the 

 button. The sensor will blink green for 1 second and 

then constant amber for 3 seconds.

To exit without saving press the 

 button. The sensor 

will blink red for 1 second and then constant amber for 3 
seconds.

NB:

 Hygiene fl ush run-on time is 30min. When 

connected to the Interface module activating the hygiene 
cycle will be common across all sensors in the network.

reset to factory settings

Enter into confi guration mode. Point the ICU at the 

sensazone

 and press the 

9

: the sensor blinks green once. 

This returns all settings to the default factory settings.

To save the setting and exit ICU confi guration mode press 
the 

 button. The sensor will blink green for 1 second and 

then constant amber for 3 seconds.

To exit without saving press the 

 button. The sensor 

will blink red for 1 second and then  constant amber for 3 
seconds.

To activate the walk test and cleaning mode the 

sensazone

 

should be in normal operating mode.

confi guring light threshold 

(when SZ/LFC is connected)

Enter into confi guration mode. Point the ICU at the 

sensazone

 and press the 

2

; the sensor blinks green once.

Decrease or increase the light threshold by pressing the
and

buttons respectively. The sensor blinks green every 

time

or

is pressed and blinks red when the  minimum or 

maximum value is reached.

Press 

 button to verify the sensor light threshold  setting; 

the sensor displays the current setting by fl ashing green.

Single fl ash:

 minimum sensitivity setting.

Double fl ash:

 medium sensitivity setting.

Triple fl ash:

 maximum sensitivity setting. 

Save setting and exit ICU confi guration mode by pressing 
the 

 button. The sensor will blink green for 1 second and 

then constant amber for 3 seconds.

To exit without saving press the 

 button.The sensor 

will blink red for 1 second and then constant amber for 3 
seconds.

NB:

 Changing light threshold will only take effect on the 

individual sensor, other sensors in the system will keep 
their light threshold settings.

confi guring fan run-on time 

(when SZ/LFC is connected)

Enter into confi guration mode. Point the ICU at the 

sensazone

 and press the 

3

; the sensor blinks green once.

Decrease or increase the fan run-on time by pressing the
and

buttons respectively. The sensor blinks green every 

time

or

is pressed and blinks red when the  minimum or 

maximum value is reached.

Press 

 button to verify the sensor light threshold setting; 

the sensor displays the current setting by fl ashing green.

Save setting and exit ICU confi guration mode by pressing 
the 

 button. The sensor will blink green for 1 second and 

then constant amber for 3 seconds.

To exit without saving press the 

 button.

The sensor will blink red for 1 second and then constant 
amber for 3 seconds.

NB:

 The fan run-on time is in addition to the occupancy 

run-on time. Changing the fan run-on time will be 
common across all sensors in the network.

 number of fl ashes: 

5

fan run-on time: 

15 

30 

60

(minutes)

14

 0118 969 1611 | [email protected] | www.cistermiser.co.uk

Summary of Contents for sensazone SZ/ASK

Page 1: ...rface Module A sensazone Light and Fan Control 3 To control the water supply to multiple areas of a washroom simultaneously Examples include a washroom divided into different areas and a washroom with two or more entrances sensazone core product A sensazone Interface Module Additional Sensor Kits Additional Valve Kits where applicable to a maximum of 3 valves per system 4 To control the water supp...

Page 2: ...adaptor 7 2 x universal fixing plug 8 2 x 6 x 1 1 2 screws 9 4 x 4 x 1 2 screws 10 4 x sticky pads 11 Extension cable to mains power adaptor 1 25m 12 Extension cable to solenoid valve 3m 1 sensazone Interface module 2 Sticky Pads x 2 3 Infrared Control Unit ICU 1 1 Solenoid valve either 15mm 22mm 1 or 11 4 Only supplied with 15mm or 22mm 2 2 3 4 5 6 7 8 9 10 11 12 3 2 0118 969 1611 sales cistermis...

Page 3: ...or 22mm 4 5 Additional Sensor Kit supplied parts 1 Sensor assembly consisting of sensor unit and backplate 2 2 x universal fixing plug 3 2 x 6 x 1 1 2 screws 4 4 x sticky pads 5 Extension Y Cable 1 4 2 3 sensazone Light and Fan Control SZ LFC supplied parts 1 sensazone Light Fan Control 2 Screws x 2 3 Fixings x 2 4 Sticky Pads x 4 1 2 4 5 3 0118 969 1611 sales cistermiser co uk www cistermiser co ...

Page 4: ... in the common entrance the water lights and fans will be activated in all areas of the washroom Example layout for single common entrance Scenario 1 and 2 Example layout for multiple entrances Scenario 3 and Scenario 4 When occupancy is detected at one of the entrances the water lights and fans will be activated in all areas of the washroom DOOR MINIMUM 1 METRE MINIMUM 1 METRE 4 0118 969 1611 sal...

Page 5: ... Grey or rainwater supply to washroom Grey or rainwater supply to washroom Max 3 metres cable length from sensor to power supply Max 100 metre cable length between SZ IF B and SZ LFC D Max 1 85 metres cable length CEILING A A C C E E D B Detection Zone 5 metres Detection Zone 5 metres 2 2 metres 2 2 metres 5 0118 969 1611 sales cistermiser co uk www cistermiser co uk Sensor s installation Refer to...

Page 6: ...and SZ LFC D Sensor s installation Refer to page 7 for details SZ IF installation Refer to page 7 for details SZ LFC installation Refer to page 8 for details Valve installation Refer to page 8 for details Mains power adapter Refer to page 9 for details A B D C E Cold water supply to washroom Cold water supply to washroom Isolating Valve not supplied Isolating Valve not supplied Hot water supply to...

Page 7: ...o go out of the same exit ensure that the wire is routed around the sensor as shown in the diagram below 6 Secure sensor unit to base plate and twist clockwise to lock into position SZ IF Installation Position the sensazone Interface Module SZ IF in accordance with the following 1 The cable length from the SZ IF to the furthest valve must NOT exceed 30m 2 The cable length from the SZ IF to the SZ ...

Page 8: ...ot exceed 8A 4 Connect the live feed for the fans to the FAN contactor Ensure load does not exceed 8A 5 Replace lid with screws provided before restoring power WARNING This is a functional switching device and must not be used for safety or maintenance isolation WARNING This device is intended for use with hazardous voltages The installation and maintenance of this device must be carried out by a ...

Page 9: ... co uk www cistermiser co uk 4 Testing and commissioning start up operation When the sensazone is powered up the LED will be a constant amber for up to 15 seconds after which it will flash amber for 5 seconds The water supply ies into the washroom will now be on for the default run on time of 15 minutes The default run on time can be changed to 30 minutes See the ICU guide in section 7 normal oper...

Page 10: ...device please read these installation instructions carefully SZ ASK Control classification Independent Maximum load 3 x 2W 0 33A 6VDC EMC emissions tested at load Rated temperature range 0 40 deg C Action classification Type 1 Y Pollution classification Degree 1 Ingress protection IP55 or IP65 with respect to room when smooth non porous ceiling tile used factory settings Range 2 2m high x 5m diame...

Page 11: ...5 Component dimensions 134mm 101mm 93mm 130mm 125mm 93mm 93mm 124mm 1 valve 11 4 valve 15mm or 22mm valve 76mm 41mm 82mm 31mm 148mm 11 0118 969 1611 sales cistermiser co uk www cistermiser co uk ...

Page 12: ...nutes Option 2 Run on time adjustment 30 minutes Sequence of programme once option has been selected Wait for single green flashing LED Wait for double green flashing LED Once your option has been chosen the LED will be constant green for 5 seconds Cup your hand over the sensor for 2 seconds to select this option The LED will be constant green for 5 seconds Cup your hand over the sensor for 2 seco...

Page 13: ...figuring sensor sensitivity range Enter into configuration mode Point the ICU at the sensazone and press the 1 the sensor blinks green once Decrease or increase the sensor range by pressing the and buttons respectively The sensor blinks green every time or is pressed and blinks red when the minimum or maximum value is reached Press button to verify the sensor sensitivity setting the sensor display...

Page 14: ...ttons respectively The sensor blinks green every time or is pressed and blinks red when the minimum or maximum value is reached Press button to verify the sensor light threshold setting the sensor displays the current setting by flashing green Single flash minimum sensitivity setting Double flash medium sensitivity setting Triple flash maximum sensitivity setting Save setting and exit ICU configur...

Page 15: ... have not been exceeded There is water in one zone but not all zones Ensure water pressure does not exceed the maximum working pressure of the valve water at outlets at all times Sensor LED not lit Check electrical power supply to the sensor and all electrical connections to the valve If electrical power confirmed please contact Cistermiser for further advice Valves not opening or closing when the...

Page 16: ...is faulty please either contact Cistermiser directly on 0118 969 1611 or at warranty cistermiser co uk with a photograph and the serial number to diagnose the cause of the problem The warranty on Cistermiser products can be extended within one year of date of manufacture at no cost to three years from the date of installation by completing the enclosed warranty card or at www cistermiser co uk war...

Reviews: