background image

14   |  cistermiser.co.uk

   Have a question? Call our customer support team on 0118 969 1611

Wave/walkaway mode switching (this will restore default settings)

Sensor will flash single 

central 

green

 LED 

for wave mode

The sensor will flash one central 

green

 LED to indicate wave function, 

to change function put your hand in 

front of the sensor for 3 second.  

A

B

C

or double top/bottom 

green

 

LEDs for walkaway mode

11. Advanced settings guide

Carry out only if settings need to be changed.

1

Disconnect power, wait for 5 seconds and reconnect.

If a hand is not placed over the sensor, it will go into normal operation mode.

You are now in configuration mode

2

3

Move your hand to the distance from the sensor you would like 

to set as maximum range. Wait 8 seconds until constant triple 

green

 LEDs show.

Sensor distance 

is now set.

B

C

Stand at the distance from the sensor you would 

like to set as maximum range. Wait 8 seconds 

until constant triple 

green

 LEDs show.

Sensor distance 

is now set.

C

B

X 1  

Wait for 

1

 x triple  

red

 

LEDs to enter 

wave/ walkaway 

setting

A

 

Wait for 

2

 x triple

  

red

 

LEDs to enter

  

sensing range

  

mode

X 2  

A

 

Wait for 

2

 x triple

  

red

 

LEDs to enter

  

sensing range

  

mode

X 2  

Wave sensing range adjustment 

(when Wave variant is selected)

Walkaway sensing range adjustment 

(when Walkaway variant is selected)

When flashing

 

triple

amber

.

Place hand 4-6cm from sensor until 

constant triple

 

green 

LEDs, then 

remove hand.

 

During the triple

 

red

 

flash briefly 

place your hand in front of

the sensor.

 

Briefly place your hand in front of 

the sensor until triple

 

green

 

LEDs 

flash slowly. Range configuration 

mode will then be ready.

 

Briefly place your hand in front of 

the sensor until triple

 

green

 

LEDs 

flash slowly. Range configuration 

mode will then be ready.

Summary of Contents for EasyflushEVO

Page 1: ...EasyflushEVO EVO 1 5 EVO 2 EVO CISTERN A Cistermiser OUR WORLD IS WATER 0 t 0 0 CIPHE 4 s ciphe org uk ISO 9001...

Page 2: ...Screw packer 15 IR activation label walk wave 16 Mains transformer 17 Clamp plate fixing screw 18 Mains transformer fixing screws 19 Battery case 20 Sticky pad 1 Introduction EasyflushEVO is an infrar...

Page 3: ...e 13 Inlet Valve 14 IR Sensor unit 15 Sensor gasket 16 Sensor nut 17 Clamp plate 18 Screw packer 19 IR activation label walk wave 20 Mains transformer 21 Clamp plate fixing screw 22 Mains transformer...

Page 4: ...The flush is activated by the IR Sensor unit This can be configured to flush on a wave default or flush when the user walks away Wave default Walk Away Memory Flush If a flush is activated while the...

Page 5: ...must be level 3 Valve Installation Before commencing installation isolate mains power supply and water supply Fit Cistern Cistern supplied with EVO CISTERN only Ensure cistern is mounted level Instal...

Page 6: ...full flush volume The height of the EasyflushEVO flush valve water level and the filling valve float level must be at the same height To adjust EasyflushEVO Fill Valve rotate the adjuster at top of v...

Page 7: ...flush when the user s hand is placed in front of the sensor Alternatively with the Walkaway activation setting the WC will automatically flush when the user leaves the cubicle See Config in section 1...

Page 8: ...er See note 30 38mm Side front adaptor NOTE For holes between 40 and 50mm contact Cistermiser for a hole adapter A hole diameter larger than 50mm is a non standard installation Sensor gasket Sensor fa...

Page 9: ...to 10 units CAUTION Risk of electric shock Isolate supply before working on wiring 6 Power Connections Isolate mains power supply before proceeding Mains wiring should be undertaken by a competent pe...

Page 10: ...e flash once per second Servo motor obstruction Call Cistermiser for advice 2 red LEDs single flash once per second Memory flush refilling Alternating 3 green LEDs rising Low battery power fault 1 red...

Page 11: ...tenance Fill valve supplied with EVO CISTERN only Periodically rinse the inlet filter and valve diaphragm If the diaphragm is damaged contact Cistermiser for a replacement You may rinse the filter or...

Page 12: ...duration after part flush Refill duration after full flush Part flush duration Full flush duration Power requirements Normal battery life Cleaning Lens care Electronic specification Control classifica...

Page 13: ...13 10 Component dimensions EVO 1 5 EVO 2 EVO CISTERN 446 263 316 5 TO BOTTOM OF CISTERN 200 30 6 LITRE 119 5 122 5 182 5 WATER LEVEL OVERALL HEIGHT RANGE 239 5 299 5 60mm HEIGHT ADJUSTMENT EVO1 5 1 5...

Page 14: ...green LEDs show Sensor distance is now set B C Stand at the distance from the sensor you would like to set as maximum range Wait 8 seconds until constant triple green LEDs show Sensor distance is now...

Page 15: ...our hand in front of the sensor The valve will start to flush and triple green flashing LEDs will be seen HOLD HAND STEADY During the triple red flashing briefly place your hand in front of the sensor...

Page 16: ...g the sensor displays the current setting by flashing green see table Save setting and exit ICU configuration mode by pressing the button Exit without saving by pressing the button 5 Button descriptio...

Page 17: ...activation and de activation Point the ICU at the EasyflushEVO sensor and press the hygiene cycle button the sensor blinks green Pressing the and buttons switches the hygiene flush function on or off...

Page 18: ...gh water will continuously flow into the cistern and out of the overflow Flush valve not activating The sensor light does not flash when a hand is placed in front of it Ensure the power supply is conn...

Page 19: ...warranty and extended warranty Cistermiser products are guaranteed for 12 months from the date of manufacture The guarantee is for faulty products and parts only there is no labour warranty If you bel...

Page 20: ...ght is adjusted so the water line is level with the indicator on the Flush Valve 3 Ensure water supply is activated For EVO CISTERN 0 1 10 bar 4 Check sensor is mounted in correct position refer to se...

Page 21: ...Have a question Call our customer support team on 0118 969 1611 cistermiser co uk 21 Notes...

Page 22: ...22 cistermiser co uk Have a question Call our customer support team on 0118 969 1611 Notes...

Page 23: ...Have a question Call our customer support team on 0118 969 1611 cistermiser co uk 23...

Page 24: ...imate is a domestic limescale prevention device that prevents limescale build up and soft water corrosion in combination boilers and other domestic hot water appliances combimate co uk Talon is the UK...

Reviews: