 Suggested Minimum Dryer Make-up Air Requirements

Dryer

Dryer Pocket

  Maximum Air Flow   Duct Size For           Required Make-up

Model

Capacity

  Rate per Pocket         Service Connection      Air Area per Pocket

lb

kg

cfm

 m3/h          inch          mm

    sq. inch   cm2

C 30 ST

30

13.6

450

  765

       6              153

87

  561

C 75 ST

75

34

1000

  1700

      12              305

192

  1240

C 110

110

50

2200

 3740

      12              305

422

  2723

C 110 E/S

110

50

850

 1445

       8              203

163

  1052

C 125

125

56.7

2000

 3400

      12              305

384

  2477

C 150

150

68

2250

 3825

      12              305

432

  2787

HD175

175

79.4

2780

 4726

      12              305

534

  3445

HD190

190

86.2

3000

 5100

      12              305

576

  3716

HD20.1

20

9.1

450

 765

       6              153

87

  561

HD30SL

30

13.6

600

1020

       8              203

116

  748

HD30.1

30

13.6

625

  1063

       8              203

120

  774

HD50.1

50

22.7

850

 1445

       8              203

164

  1058

HD75.1

75

34

1000

 1700

       8             203

192

  1240

HD80.1

80

36.3

1000

 1700

      10              254

192

  1240

Notes:

1)  The Model C 30 ST has 2 pockets per dryer, each pocket has the above listed characteristics;

     each pocket is exhausted separately with a 6" (153mm) duct.

2)  The Model C 75 ST has 2 pockets per dryer, each pocket has the above listed characteristics;

     both pockets have one 8" (203mm) exhaust manifolded into one 12" (305mm) exhaust duct for

     exhaust connection.

3)  For the C  30 ST and the C 75 ST Models, the Required Make-up Air Area shown in the table

     should be doubled since it is shown per pocket,only.

Summary of Contents for HD50.1

Page 1: ...acturingCo 831 S First St P O Box 32270 Louisville Ky 40232 2270 Tel 502 587 1292 Fax 502 585 2333 Sales Fax 502 585 3625 Service Parts Fax 502 681 1275 OWNER S MANUAL 50 lb HD LAUNDRY DRYER HD50 1 TH...

Page 2: ...occupants Immediately call your gas supplier from a neighbor s phone Follow the gas supplier s instructions If you cannot reach your gas supplier call the fire department Installation and service mus...

Page 3: ...apparell __ QUE FAIRE SI VOUS SENTEZ UNE ODEUR DE GAZ Ne pas tenter d allumer d apparell Ne touchez a aucun interrupteur Ne pas vous servir des telephones se trouvant dans le batiment ou vous vous tro...

Page 4: ...s wrinkles from setting in and reduces the possibility of spontaneous combustion WARNING Be safe shut main electrical power and gas supply off externally before attempting service WARNING Never use dr...

Page 5: ...stall to diagnose troubles to adjust remove or replace defective equipment or a part nor does it include any responsibility for transportation expense which is involved therein The warranty of Cissell...

Page 6: ...stallation 14 15 Gas service Installation Instructions 16 Gas Pipe Size Chart 17 Steam Piping Installation Instructions 18 19 Dryer Installation with Multiple Exhaust 20 21 Dryer Make Up Air Requireme...

Page 7: ...following symbols are used in this manual and or on the machine NOTE On Marche Ein Conectado Off Arr t Aus Desconectado Hot Do Not Touch Hei Nicht Beruhren Haute temperature Ne pas toucher Caliente n...

Page 8: ...d allow free access to the rear of dryer for future servicing of belts pulleys and motors Installation clearance from all combustable material is 0 ceiling clearance 0 rear clearance and 0 side cleara...

Page 9: ...removed daily or as required to prevent an over accumulation IMPORTANT Provide adequate clearance for air openings into the combustion chamber Permanent press durable press and other modern day fabri...

Page 10: ...le c t r ic D r y e r s N o n R e v e r s i n g R e v e r s i n g 2 0 8 V 5 0 6 0 3 P H 8 9 A 8 8 A 2 4 0 V 5 0 6 0 3 P H 7 2 7 8 A 7 2 7 8 A 3 8 0 4 1 5 V 5 0 3 P H 4 4 4 8 A 4 3 4 6 A 4 8 0 V 6 0 3...

Page 11: ...Page 11 HD50 1 Dryer Dimensions Gas...

Page 12: ...the right block and the yellow green grounding wire PE should be connected to the grounding block G Dryers must be electrically grounded by a separate 14 or larger green wire from the grounding termi...

Page 13: ...can result in unsufficient gas supply which can lead to a bad heating up and a poor drying quality When the dryer is used in combination with a weighing platform the gas supply pipe has to be made of...

Page 14: ...dryer 3 Check the altitude of dryer 4 Check with utilities company for proper gas pressure and gas supply line 5 Natural gas only check the gas pressure inlet supply to dryer 11 water column 27 4 mba...

Page 15: ...y piping system during any pressure testing of that system at test pressures in excess of 1 2 psi 04 bar The dryer must be isolated from the gas supply piping system by closing it s individual manual...

Page 16: ...es should be connected upstream from the loop WARNING LIQUIFIEDPETROLEUMGASESONLY A gas pressure regulator for liquified petroleum gases is not furnished on the gas heated clothes dryers This regulato...

Page 17: ...00000 330000 350000 380000 400000 430000 450000 480000 504000 550000 605000 650000 705000 750000 806000 850000 907000 960000 1000000 3 4 3 4 3 4 3 4 3 4 3 4 1 1 1 1 1 4 1 1 4 1 1 2 1 1 2 1 1 2 2 2 2 2...

Page 18: ...return line it is recommended that each have a 3 4 union and 3 4 globe valve This will enable you to disconnect the steam connections and service the dryer while your plant is in operation 5 Before c...

Page 19: ...Page 19 Steam Piping Installation Illustration...

Page 20: ...ipesentering multipleexhaustpipe Seechartbelow HD50 No of Dryers Duct Diameter in inches in CM 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 8 12 14 16 18 20 22 23 24 26 27 28 29 30 3...

Page 21: ...4 Zero inches clearance to combustible material allowed on sides and at points within 4 inches 102 mm of front on top 5 Heat loss into laundry room from dryer fronts only is about 60 Btu h per square...

Page 22: ...305 576 3716 HD20 1 20 9 1 450 765 6 153 87 561 HD30SL 30 13 6 600 1020 8 203 116 748 HD30 1 30 13 6 625 1063 8 203 120 774 HD50 1 50 22 7 850 1445 8 203 164 1058 HD75 1 75 34 1000 1700 8 203 192 1240...

Page 23: ...ure plenum with service door This separates the dryer air from the room comfort air If dryers use room air instead of outside air additional heat loss can be another 25 Btu h 6 3 kcal h for each cubic...

Page 24: ...haust each dryer separately 4 Do not install wire mesh or other restrictions in the exhaust duct 5 Use clean outs in the exhaust duct and clean periodically when needed 6 Never exceed 0 3 inches water...

Page 25: ...nd cleaning aids Heed any warnings or precautions 7 Never tumble fiberglass materials in the dryer unless the labels say they are machine dryable Glass fibers break and can remain in the dryer and cou...

Page 26: ...ecovery from a safety lockout requires one of the following A Opening the main door thus interrupting power to the DSI module and allowing dryer diagnostic trouble shooting B Disconnecting the entire...

Page 27: ...switch 1 D Under basket and burner housing thermal safety switches 2 E Variable thermostat 1 F Push to start switch 1 THERMOSTATCALLS FORHEAT IGNITIONCYCLE BEGINS GASVALVE ON MAINBURNERFLAME DETECTED...

Page 28: ...periodically Adjust tension by movement of idler bracket Lubricate idler pulley once every two months using six grams of high temperature grease Do not over grease 5 Electric motor Keep motor clean a...

Page 29: ...eep dryer area clean and free of gasoline combustible materials and other flammable liquids or vapors 9 Do not obstruct the flow of combustion make up air and ventilating air 10 Check gas pressure per...

Page 30: ...ion shown hold switch mounting bracket firmly and adjust switch actuator D with needle nose pliers at E by twisting actuator right or left whicheverisneeded sothatswitchcloseswhenendofairblade engages...

Page 31: ...ture synthetic blends including a mixed wash load LOW HEAT 135 F 58 C exhaust temperature delicate sheer fabrics 5 Press the push to start button to start the drying cycle The heat or drying light wil...

Page 32: ...heckthetwo B pinsforequalclearance 3 Withthepinsinposition tightenthetwoNo 5boltsuntilflushagainstbackofdryer Retightencastiron bearingorgearreducer mountingboltsinthenumericalorderindicatedinFigure3...

Page 33: ...Microswitch door 4 SC504 Pop rivet 5 TU10290 Lint trap w a 6 TU10362 Lint Screen TU5225 Lint screen frame 7 TU14900WHT Jacket white 8 TU3211 Leveling bolt 9 430146179 Gasket 5 feet 10 TU7733 Screw sel...

Page 34: ...Trim Controldoor 2 LA 00121 0 Lock Control door 3 LA 11941 0 Camlock Controldoor 4 SB 00951 0 Screw Phillips 8X7 16flathd 5 TU14957 Logo 6 TU15278 Panel Welded asm 7 TU15446 Supportarm 8 CA 13098 0 Do...

Page 35: ...2 TU15536 Magnet read switch 3 MD 00360 0 Gasket door rim gasket 4 SB 00852 0 Washer 1 4 external starluck 5 SB 00921 0 Screw 1 4 20 round head 6 TU15073 Door hinge spacer 7 TU15076 Door rim w a 8 TU1...

Page 36: ...15727WHT Front panel assembly complete with out E stop button 1 ESA 00862 0 Reed switch 2 SB 00975 0 6 32Screw 3 TU14435 Emergency stop 4 TU14951 Front panel W A OPL 5 TU2876 Door catch 6 TU3213 Pop r...

Page 37: ...00699 0 Bezel Coin box 2 ESA 00862 0 Reed switch 3 SB 00975 0 6 32 Screw 4 SB 00924 0 4 40 x 3 8 Screw 5 SB 00938 0 4 Ext tooth lockwasher 6 TU15050WHT Front panel W A Coin 7 TU2876 Door catch 8 TU321...

Page 38: ...EA 00606 0 Thermostat 4 EA 00607 0 Thermostat knob 5 EA 00608 0 Grommet rubber 6 SB 00828 0 Screw 8 32 X 1 2 7 TU15010 Thermostat bracket 8 TU3266 Nut brass 8 32 9 TU3624 Screw 6 32 X 1 4 10 TU7733 S...

Page 39: ...SA 00961 0 Complete Assmebly 1 CA 13172 Mtg bracket 2 EA 00411 0 Switch 220 Degree 3 SB 00828 8 32x1 2 Screw 4 SB 00952 6 32x3 8 Screw 5 TU11991 Thermistor 6 TU3266 8 32 Hex nut 7 TU3400 6 32 Hex nut...

Page 40: ...Screw selfdrill 8 18x1 2 long 6 254 00060 10 Humidity sensor Ref No PartNo Description TU14723 PROHCSensorassembly lower 1 CA 13067 0 Bracket sensor 2 EA 00411 0 Switch 220 degrees 3 SB 00828 0 Screw...

Page 41: ...o Description 9 TU1771 Tinnerman nut 10 TU3266 8 32 Hex nut 11 TU3400 6 32 Hex nut 12 TU4958 8 32 Carriage bolt 13 TU9524 6 S M Screw 14 TUD0355 Overlay 15 TUT316 LED light 24V W 1 4 Q C 16 SEE BELOW...

Page 42: ...mach truss HD 8 32X3 8 3 TU14404 Controller OPL COIN board new 4 TU14406 Overlay 5 TU3266 Nut hex brass 8 32 6 TU3400 Nut hex 6 32 7 TUD0336 Coindrop hanke 25C 8 TUD0367 Nut hex 5 40 machine 9 TU1225...

Page 43: ...mounting rev board 11 TU14936 Overlay non reversing TU14937 Overlay reversing CONTROL PANEL ASSEMBLY DUAL TIMER REVERSING and NON REVERSING Ref No Part No Description 12 TU15247 Control panel 13 TU152...

Page 44: ...Description TU15254 ReversingControlPanelComplete 1 TU15252 Control panel 2 M262 8 32 Screw 3 TU14137 Buzzer24V Optional 4 TU14404 DMPControl 5 TU15184 Overlay 6 TU3400 6 32Nut 7 TU12253 6 32 Stud 8...

Page 45: ...professional 2 254 00018 00 Lable PROmoisturecontroller 3 M262 Screw machine truss 8 32x 3 8 long 4 TU3266 Nut hex brass 8 32 5 TU3400 Nut hex 6 32 6 TU14701 Spacer nylon 1 4 O D x 5 16 long 7 TU14452...

Page 46: ...a OPL Coin 2 SB 00949 0 Fastener plastic kickplate 3 CA 00647 0 Lint door handle 4 CA 00838 0 Kickplate 5 SB 00836 0 Screw Pancake 10 6 CA 00655 0 Trim Rubrail specify35 Lg 7 TUD0412 Plug OPLOnly 8 LA...

Page 47: ...sm Galv Belt Drive TUS15532 Basket Spyder Asm S S Belt Drive 1 TUS15496 Stainless steel basket assy TU15496 Galvanized basket assy 2 TU15495 Spider assy Belt Drive TU15494 Spider assy Gear Drive 3 SB...

Page 48: ...age 48 REAR VIEW Ref No PartNo Description 1 TU14725 Cover plate 2 TU14900 Jacket white 3 TU15061 Upper rear cover 4 TU15062 Lowerrearcover 5 TU7733 Screwselfdrilling8 18x1 2 6 TU15671 Air switch cove...

Page 49: ...SEMBLY TU8206 Ref No Part No Description 1 F888 E Ring 2 TU1770 Insulator 3 TU1771 6 Tinnerman Nut 4 TU2463 ActuatorArm 5 TU3219 6 x 1 S M S 6 TU3476 Decal 7 TU7733 8 x 1 2 S M S 8 TU8155 Micro Switch...

Page 50: ...8 16 hex nut 13 TU3243 3 8 Internal tooth washer 14 TU15686 10 32 x 3 4 lg Set screw One required for rotation sensor ONLY Ref No Part No Description 1 TU15173 18 Dia Sheave Non reversing TU15157 18 D...

Page 51: ...2HP115 230 50 60 1DoubleMtr N R 4 DA 00510 0 SheavecastIR2 5X1 250hz DA 00516 0 Sheavecast IR2 0X1 260hz 5 DSA 00812 0 13 Fan50hz DSA 00773 0 12 Fan60hz 6 SB 00813 0 Nut 1 2 20 left hand rev lock 7 SB...

Page 52: ...ng Cup 2 8 TM112 Large End Cap 1 9 TM115 1 4 Pipe Plug 1 10 TM117 Large Bearing Cone 2 11 TM102 Worm Gear 1 12 TM120 Oil Seal 2 13 TU2623 Cap Screw 3 8 16 x 1 1 2 4 14 TU2839 Cap Screw 1 4 20 x 7 8 8...

Page 53: ...PH 10 TU33 BRACKET MTRDRIVE 28X36DBLMT 11 IB140 WASHER FLAT3 8 12 TU4787 NUT HEX3 8 16 13 TU14414 SENSOR INDUC ROTAT BALLUFF 14 VSB134 WASHER SPLITLOCK3 8 15 TU3246 SCREW CAPHEXHD3 8 16 16 TU4934 NUT...

Page 54: ...SING Ref No PartNo Description 1 DA 11909 0 1 2HP200 415 50 60 3 MTR315 1 2HP230 460 50 60 1 2 TU6559 Sheave 2 0 dia 60hz TU10998 Sheave2 5 dia 50hz 3 VSB130 Washer cut 5 16 4 TU2814 Washer lock 5 16...

Page 55: ...er Motor 2 C249 Nut Hex 5 16 18 3 CA 12059 0 Idler adjustment plate 4 DA 00517 0 Housing idler bearing 5 DA 00518 0 Bearing 6 DA 11711 0 Idler shaft 7 TU14691 V belt pulley 8 TU15175 Idler pulley 9 9...

Page 56: ...SB 00868 0 Bushing insulating 6 TU13516 Contactor 24VAC 7 TU15138 Transformer 115 208 230V 24VA 8 GA 00765 0 Ignitormodule60Hz 9 GA 11007 0 Ignitormodule50Hz C E Ref No PartNo Description 10 TU14958...

Page 57: ...ing insulating 5 SB 00868 0 Bushing insulating 6 TU13516 Contactor 24VAC 7 TU13802 Transformer 115 208 240V 24VA 8 TU13521 Contactor 208 240V TU14684 Contactor 346 600V Ref No PartNo Description 9 TU1...

Page 58: ...rw bracket 8 TU2226 Bracketassembly 9 TU2846 Lock washer 1 4 10 TU2878 10 16Sheetmetalscrew 11 TU6263 10 24Screw hex Ref No PartNo Description 12 TU7733 8 12Screw self drilling 13 TU15693 Ignitor mtg...

Page 59: ...w bracket 8 TU2226 Bracketassembly 9 TU2846 Lock washer 1 4 10 TU2878 10 16Sheetmetalscrew 11 TU6263 10 24Screw hex Ref No PartNo Description 12 TU7733 8 12Screw self drilling 13 TUD0242 Ignitor mtg b...

Page 60: ...assembly 1 CA 13221 0 Steam coil 2 CFB1300 Cable GREENFIELD 1 2 X 13 3 CSA 01602 0 Adaptor w a 4 TU13517 Valve steam solenoid 3 4 24V 5 TU2735 Reducer pipe 1 x 3 4 6 TU4608 Nipple 3 4 x 2 black 7 TU47...

Page 61: ...830 200 208V 30KWCompleteassembly 1 CA 11984 0 Rear heater box cover 2 EA 00243 0 Bonnet high limt switch 3 EA 00472 0 Heaterelement 240V EA 00473 0 Heaterelement 208V 4 EA 10232 0 Switch cover 5 EA 1...

Page 62: ...14406 OVERLAY COIN TU14137 BUZZER24V DOUBLETIMER PARTS EA 00606 0 THERMOSTAT ROBERTSHAW EA 00411 0 SWITCH 220DEGREES EA 00619 0 STARTSWITCH FG147 TOGGLESWITCH2POSITION TUT316 LIGHT LED24V TU12874 TIME...

Page 63: ...Page 63...

Reviews: