Page 59
NOTE:
For conversion from natural gas to
propane gas.
1.
Order:
6 each—TU3539 orifice with
no. 34 drill size.
2 each—K555 natural gas
to LP gas conversion kit and
follow directions.
Specifications (propane)
Propane—1.53 specific gravity
Calorific value—2,500 Btu/cu. ft.
Gas Input—87,500 Btu/hour per
burner total
ORIFICE SIZE - NORMAL
ORIFICE SIZE - HIGH
MODEL
(SEA LEVEL)
(3,000 FT.)
NATURAL
PROPANE
NATURAL
PROPANE
L52CD42G
No. 9
No. 31
No.
No.
In altitudes above 2000 feet, consult with factory.