background image

Cisco UCS C200 M2 High-Density SFF Drive Rack-Mount Server

26

CONFIGURING the SERVER

STEP 8

SELECT OPTIONAL DVD-RW DRIVE

The front panel offerings are:

Controller panel, or

DVD-RW drive, with dual-layer (DL) support

The standard offering is a controller panel. See 

Figure 2 on page 4

 for a representation of both 

offerings.

Select Front Panel Configuration

The available front panel configurations are listed in 

Table 10

.

Approved Configurations

(1) Select the controller panel, or

(2) Select the optional DVD-RW optical drive

Caveats

The DVD-RW optical drive is optional. If you order it, you will not have a front panel 
controller, and some connectors, LEDs, and controls will no longer be available. The optical 
drive supports dual-layer media.

Table 10

  Available Front Panel Configurations

Product ID (PID)

PID Description

UCSC-CON-SFF-C200

Controller panel for UCS C200 SFF Rack Server

UCSC-DVD-SFF-C200

DVD-RW Drive for UCS C200 M2 SFF Rack Server

Summary of Contents for UCS C200 M2

Page 1: ...MS PUBLICATION HISTORY 170 WEST TASMAN DR SAN JOSE CA 95134 REV A 14 MAY 16 2013 WWW CISCO COM Spec Sheet This product has been discontinued Cisco UCS C200 M2 High Density Small Form Factor Drive Rack Mount Server ...

Page 2: ...10 SELECT AC POWER CORD s 28 STEP 11 ORDER OPTIONAL TOOL LESS RAIL KIT 31 STEP 12 ORDER OPTIONAL CABLE MANAGEMENT ARM 32 STEP 13 ORDER A TRUSTED PLATFORM MODULE 33 STEP 14 SELECT OPERATING SYSTEM AND VALUE ADDED SOFTWARE 34 STEP 15 SELECT OPERATING SYSTEM MEDIA KIT 37 STEP 16 SELECT SERVICE and SUPPORT LEVEL 38 OPTIONAL STEP ORDER RACK s 42 OPTIONAL STEP ORDER PDU 43 SUPPLEMENTAL MATERIAL 44 CHASS...

Page 3: ...t one rack unit 1RU rack server that extends the capabilities of the Cisco Unified Computing System The server uses Intel s latest Xeon 5600 Series multi core processors with 12 DIMM slots and 2 PCIe slots The UCS C200 M2 SFF Server is available with eight 2 5 inch SFF hard disk drives or solid state drives Figure 1 Cisco UCS C200 M2 High Density SFF Rack Server Front View Rear View ...

Page 4: ...nt View Control Panel Installed For more information about the KVM cable connection see KVM CABLE page 54 1 KVM console connector1 Notes 1 The KVM connector is not available if the optional DVD RW optical drive is installed instead of the front panel control module 7 System fault LED 2 Reset button 8 Locator button LED 3 Power supply fault LED2 2 Not available if an optional DVD RW drive is instal...

Page 5: ...ivity LED 2 Reset button 6 Hard drives up to 8 3 Locator button LED 7 Hard drive fault LED 4 Power button Power status LED 8 Hard Drive Activity LED 1 Power supply up to 2 5 Video connector DB15 VGA 2 10 100 Ethernet management port RJ 45 6 10 100 1000 Gigabit Ethernet ports 2 3 USB 2 0 connectors 2 7 Low profile PCIe card slot PCIe slot 7 4 Serial connector DB9 8 Standard profile PCIe card slot P...

Page 6: ... slots Two PCIe slots on a riser card One full height profile half length slot with x16 connector and x8 lane One half height profile half length slot with x8 connector and x8 lane Storage controller One of the following An onboard SATA RAID 0 1 controller integrated on motherboard Intel ICH10R that can control up to four SATA drives or An optional RAID mezzanine card LSI 1068E 8 port controller m...

Page 7: ... dual layer DL support Power subsystem Up to two 650 W power supplies N 1 or nonredundant configuration options Fans Chassis Five 40 mm redundant fans Power supply Each power supply is equipped with a fan Integrated management processor Cisco Integrated Management Controller CIMC with integrated video KVM redirection Security Intelligence Operations SIO fan speed control Platform Environment Contr...

Page 8: ...CT PCIe OPTION CARD s page 21 STEP 7 ORDER OPTIONAL NETWORK CARD ACCESSORIES page 23 STEP 8 SELECT OPTIONAL DVD RW DRIVE page 26 STEP 9 ORDER OPTIONAL REDUNDANT POWER SUPPLY page 27 STEP 10 SELECT AC POWER CORD s page 28 STEP 11 ORDER OPTIONAL TOOL LESS RAIL KIT page 31 STEP 12 ORDER OPTIONAL CABLE MANAGEMENT ARM page 32 STEP 13 ORDER A TRUSTED PLATFORM MODULE page 33 STEP 14 SELECT OPERATING SYST...

Page 9: ...ncludes one power supply Does not include CPU memory hard disk drives HDDs solid state drives SSDs plug in PCIe cards or DVD RW drive Table 2 PID of the Base C200 M2 High Density SFF Rack Base Server Product ID PID Description UCSC BSE SFF C200 C200 M2 SFF Rack Srvr w 1PSU w o CPU mem HDD PCIe DVD NOTE Use the steps on the following pages to configure the server with the components that you want t...

Page 10: ... common denominator of CPU clock and DIMM clock For example Selecting lower speed DIMMs If you use an X5650 CPU which can support up to 1333 MHz DIMMs with 1066 MHz DIMMs the DIMMs will be clocked at the lower speed of 1066 MHz Selecting higher speed DIMMs If you use 1333 MHz DIMMs with an E5620 which can support up to 1066 MHz DIMMs the DIMMS will be clocked at the lower speed of 1066 MHz A01 X01...

Page 11: ...gurations Select two identical CPUs from any one of the rows of Table 3 on page 10 Caveats You can select either one processor or two identical processors For optimal performance select DIMMs with the highest clock speed for a given processor see Table 3 on page 10 If you select DIMMs whose speeds are lower or higher than that shown in the tables suboptimal performance will result ...

Page 12: ...ock speed 800 MHz 1066 MHz or 1333 MHz Ranks per DIMM 1 2 or 4 Operational voltage single voltage 1 5 V or dual voltage 1 35 V 1 5 V Registered DDR3 ECC registered DIMMs RDIMMs supporting Intel SDDC Memory is organized with three memory channels per CPU with up to two DIMMs per channel as shown in Figure 5 Figure 5 C200 M2 SFF Memory Organization ...

Page 13: ...emory error the system automatically retrieves the data from the other channel A transient or soft error in one channel does not affect the mirrored data and operation continues unless there is a simultaneous error in exactly the same location on a DIMM and its mirrored DIMM Memory mirroring reduces the amount of memory available to the operating system by 50 because only one of the two populated ...

Page 14: ...ed in either of these modes Power Saving Mode at a maximum speed of 1066 MHz Performance Mode at a maximum speed of 1333 MHz If you mix both types of DIMMs in your configuration the server forces all DIMMs to operate in Performance Mode Memory mirroring If you select the Memory RAS option be aware that it is available only with an even number of memory channels For example if you select six DIMMs ...

Page 15: ... you only have two DIMMs they need to be the same PID because you have one DIMM on each of two buses If you have four DIMMs in a 2 CPU system for example you can have two 4 GB and two 8 GB DIMMs One 4 GB 8 GB DIMM pair would located on Channel A of CPU 1 and one 4 GB 8 GB DIMM pair would be located on Channel D of CPU 2 If you have four DIMMs in a 1 CPU system for example you can have two 4 GB and...

Page 16: ...actory configurable Select RAID Options Select one RAID controller one RAID configuration option and if desired a battery backup option listed in Table 5 Table 5 Available RAID Options Product ID PID PID Description RAID Controllers UCSC RAID C 4I4E LSI MegaRAID SAS 9280 4i4e four internal and four external ports Takes up one of two available PCIe slots Supports up to four internal SAS or SATA dri...

Page 17: ...p RAID Configuration note Mezzanine card supports only RAID 0 1 and 1E R2XX RAID0 Factory preconfigured RAID striping option Enable RAID 0 Setting Requires a minimum of one hard drive R2XX RAID1 Factory preconfigured RAID mirroring option Enable RAID 1 Setting Requires exactly two drives with the same size speed capacity R2XX RAID5 Factory preconfigured RAID option Enable RAID 5 Setting Requires a...

Page 18: ...g an optional PCIe card If you choose the mezzanine card both the half height and full height PCIe card slots are still available for adding optional PCIe cards You can choose only one RAID controller integrated controller plug in PCIe controller or mezzanine card controller You can choose an optional RAID configuration RAID 0 1 5 1E 6 or 10 which is preconfigured at the factory If you do not choo...

Page 19: ...led Mounted HDDs and SSDs Product ID PID PID Description Drive Type Capacity HDDs A03 D146GC2 146 GB SAS 15K RPM SFF HDD SAS 146 GB A03 D300GA2 300 GB 6 Gb SAS 10K RPM SFF HDD SAS 300 GB UCS HDD300GI2F105 300 GB 6 Gb SAS 15K RPM SFF HDD SAS 300 GB A03 D500GC3 500 GB 6 Gb SATA 7 2K RPM SFF SATA 500 GB A03 D600GA2 600 GB 6 Gb SAS 10K RPM SFF HDD SAS 600 GB UCS HDD900GI2F106 900 GB 6 Gb SAS 10K RPM S...

Page 20: ...60 8i RAID controller Select up to eight SAS or SATA drives listed in Table 6 you can mix SAS SATA drives you cannot mix HDD SSD drives 4 LSI 1068 8 port SAS 3 0G RAID mezzanine card RAID controller Select up to eight SAS or SATA drives listed in Table 6 SAS SATA can be mixed HDD SSD cannot Caveats If the integrated RAID controller on the server motherboard is used no PCIe or mezzanine controller ...

Page 21: ...E iSCSI Half Network Interface Cards NICs N2XX ABPCI02 Broadcom 57711 Dual Port 10GbE NIC w TOE iSCSI Half N2XX ABPCI03 M3 Broadcom 5709 Quad Port 1Gb w TOE iSCSI for M3 Servers Half N2XX ABPCI01 M3 Broadcom 5709 Dual Port 1Gb w TOE iSCSI for M3 Servers Half N2XX AQPCI01 Qlogic QLE 8152 CNA 2port 10Gb SFP Copper Half N2XX AIPCI02 Intel Quad port GbE Controller E1G44ETG1P20 Half N2XX AIPCI01 Intel ...

Page 22: ...h the exception of the Virtual Interface Card VIC N2XX ACPCI01 which is a full height card If you selected a plug in RAID controller into the half height slot in STEP 4 SELECT RAID CONFIGURATION only the full height slot is available Only a single VIC card may be installed and it must be installed in a full height slot All cards will fit in either slot except the VIC card which must be installed i...

Page 23: ... You may choose one or two twinax cables for each network card ordered The cables can be different lengths however you would normally order two cables of equal lengths to connect to the primary and redundant network switching equipment Caveats The twinax cables listed in Table 8 can be ordered only for the following PCIe cards N2XX ACPCI01 Cisco UCS P81E Virtual Interface Card 2 port 10Gbps UCS PC...

Page 24: ...s Caveats The SFP 10G SR optical module listed in Table 9 should be ordered only for the following PCIe cards as they do not come by default with any opical modules N2XX ACPCI01 Cisco UCS P81E Virtual Interface Card 2 port 10Gbps UCSC PCIE BSFP Broadcom 57712 N2XX ABPCI02 Broadcom 57711 N2XX AEPCI01 Emulex OCe10102 F The DS SFP FC8G SW optical module listed in Table 9 should be ordered only for th...

Page 25: ...Cisco UCS C200 M2 High Density SFF Drive Rack Mount Server CONFIGURING the SERVER 25 Figure 6 Network Card Connections ...

Page 26: ...ront panel configurations are listed in Table 10 Approved Configurations 1 Select the controller panel or 2 Select the optional DVD RW optical drive Caveats The DVD RW optical drive is optional If you order it you will not have a front panel controller and some connectors LEDs and controls will no longer be available The optical drive supports dual layer media Table 10 Available Front Panel Config...

Page 27: ...SUPPLY The C200 M2 server can accommodate two power supplies Only one power supply is required One 650 W power supply ships with the base server chassis You can order an optional redundant power supply see Table 11 Table 11 Redundant Power Supply Product ID PID PID Description R2X0 PSU2 650W SB Redundant 650 W power supply ...

Page 28: ...A Power Cord NEMA L6 20 250V 20A plug IEC320 C13 receptacle North America CAB C13 C14 JMPR Power Cord recessed receptacle AC power cord 27 SFS 250V 10A AR Power Cord SFS 250V 10A Argentina CAB 9K10A AU Power Cord 250VAC 10A 3112 Plug Australia Cordset rating 10 A 250 V Length 8 2 ft 186570 Plug NEMA 6 15P Connector IEC60320 C13 Cordset rating 13A 250V 6 6 feet 79 2m Plug EL312MoldedTwistlock NEMA ...

Page 29: ...D Description Images Cordset rating 10A 250V 2500 mm Plug EL 218 CCEE GB2009 186573 Connector EL 701 IEC60320 C13 Connector VSCC15 Cordset rating 10A 16 A 250 V Length 8 ft 2 in 2 5 m Plug M2511 186576 OVE Cordset rating 16A 250V 2500mm Plug EL 208 187490 Connector EL 701 Cordset rating 10A 250V 500V MAX 2500 mm Plug EL 212 SI 32 186574 Connector EL 701B IEC60320 C13 EL 212 16A 250V Plug I 3G CEI ...

Page 30: ... Mount Server 30 CONFIGURING the SERVER CAB 9K12A NA Power Cord 125VAC 13A NEMA 5 15 Plug North America Image not available CAB JPN 3PIN Power Cord 3PIN Japan Image not available Table 12 Available Power Cords Product ID PID PID Description Images ...

Page 31: ...d OPTIONAL STEP ORDER RACK s page 42 for information about racks and rack equipment Table 13 Rail Kit Product ID PID PID Description R2XX G31032RAIL UCS C200 C210 Rack Server Rail Kit NOTE This third generation rail kit works in racks with square holes or 10 32 round holes and is shorter than the previous generation rail kit The new R2XX G31032RAIL measures 23 5 inches to 36 inches in length By co...

Page 32: ...e server and is used for cable management Use Table 14 to order a cable management arm For more information about the cable management arm see the Cisco UCS C200 Installation and Service Guide at this URL http www cisco com en US docs unified_computing ucs c hw C200M1 install c200M1 html Table 14 Cable Management Arm Product ID PID PID Description R2XX CMAG3 1032 Cable Mgmt Arm for R2XX G31032RAIL...

Page 33: ...cryption keys A TPM can also be used to store platform measurements that help ensure that the platform remains trustworthy Authentication ensuring that the platform can prove that it is what it claims to be and attestation a process helping to prove that a platform is trustworthy and has not been breached are necessary steps to ensure safer computing in all environments The TPM ordering informatio...

Page 34: ...vc SUSE Linux Enterprise Server SLES 1A SLES 1yr subscription svcs required 0 media SLES 3A SLES 3yr subscription svcs required 0 media UCS SLES TERMS Acceptance of Terms Standalone SLES License for UCS Servers Red Hat Enterprise Linux RHEL 2S 1G 1A RHEL 2 Socket 1 Guest 1Yr Svcs Required RHEL 2S 1G 3A RHEL 2 Socket 1 Guest 3Yr Svcs Required RHEL 2S 4G 1A RHEL 2 Socket 4 Guest 1Yr Svcs Required RH...

Page 35: ...rocessor 4 Year Support Rqd VMW VS5 STD 5A VMware vSphere 5 Standard for 1 Processor 5 Year Support Rqd VMW VS5 ENT 1A VMware vSphere 5 Enterprise for 1 Processor 1 Year Support Rqd VMW VS5 ENT 2A VMware vSphere 5 Enterprise for 1 CPU 2 Yr Support Rqd VMW VS5 ENT 3A VMware vSphere 5 Enterprise for 1 CPU 3 Yr Support Rqd VMW VS5 ENT 4A VMware vSphere 5 Enterprise for 1 Processor 4 Year Support Rqd ...

Page 36: ... CONFIGURING the SERVER VMW VC5 STD 5A VMware vCenter 5 Server Standard 5 yr support required UCS VMW TERMS Acceptance of Terms Standalone VMW License for UCS Servers Table 16 OSs and Value Added Software for 2 CPU servers continued PID Description Product ID PID ...

Page 37: ... Description RHEL 6 RHEL 6 Recovery Media Only Multilingual SLES 11 SLES 11 media only multilingual MSWS 08R2 STHV RM Windows Svr 2008 R2 ST 1 4CPU 5CAL Media MSWS 08RS ENHV RM Windows Svr 2008 R2 EN 1 8CPU 25CAL Media MSWS 08R2 DCHV RM Windows Svr 2008 R2 DC 1 8CPU 25CAL Media MSWS 12 ST2S RM Windows Server 2012 Standard 2 CPU 2 VMs Recovery Media MSWS 12 DC2S RM Windows Server 2012 Datacenter 2 ...

Page 38: ...s at peak efficiency If a problem arises that threatens business continuity the TAM provides crisis management leadership and your IT staff receives expedited access to Cisco s Technical Assistance Center TAC Note This service has qualification criteria Your company must have 1 2M of UCS equipment 200 blades and a single location to qualify for this service level Choose the desired service listed ...

Page 39: ... access any time to Cisco support professionals who can determine if a return materials authorization RMA is required See Table 20 Table 19 UCS Computing Support Service Product ID PID On Site Description CON UCS1 R200W No UC Support 8X5XNBD CON UCS2 R200W No UC Support 8X5X4 CON UCS3 R200W No UC Support 24x7x4 CON UCS4 R200W No UC Support 24x7x2 CON UCS5 R200W Yes UC Support 8X5XNBD CON UCS6 R200...

Page 40: ...f any potential liabilities This service also enables you to comply with regulatory local and federal requirements If your company has a need to control confidential classified sensitive or proprietary data you might want to consider one of the Drive Retention Services listed in Table 21 NOTE Cisco does not offer a certified drive destruction service as part of this service Table 21 Drive Retentio...

Page 41: ...e this URL http www cisco com en US products ps10312 serv_group_home html UCS Warranty Plus With Drive Retention UC PLUS DR UCWD2 8x5x4 CON UCWD2 R200WSFF UCWD3 24x7x4 CON UCWD3 R200WSFF UCWD4 24x7x2 CON UCWD4 R200WSFF UCWD5 8x5xNBD Onsite CON UCWD5 R200WSFF UCWD6 8x5x4 Onsite CON UCWD6 R200WSFF UCWD7 24x7x4 Onsite CON UCWD7 R200WSFF UCWD8 24x7x2 Onsite CON UCWD8 R200WSFF Table 21 Drive Retention ...

Page 42: ... For more information about the R42610 rack see RACKS page 50 Table 22 Racks and Rack Options Product ID PID PID Description RACK UCS1 Notes 1 Use these same base PIDs to order spare racks available only as next day replacements Cisco R42610 expansion rack no side panels RACK UCS21 Cisco R42610 standard rack w side panels RACK BLANK 001 Filler panels qty 12 1U plastic toolless RACK CBLMGT 001 Cabl...

Page 43: ...optional power distribution unit PDU is available from Cisco for the C Series rack servers including theC200 M2 server This PDU is available in a zero rack unit RU style see Table 22 For more information about the PDU see PDUs page 52 Table 23 PDU Options Product ID PID PID Description RP208 30 2P U 2 Zero RU PDU ...

Page 44: ...gh Density SFF Drive Rack Mount Server 44 SUPPLEMENTAL MATERIAL SUPPLEMENTAL MATERIAL CHASSIS An internal view of the C200 M2 chassis with the top cover removed is shown in Figure 7 Figure 7 C200 M2 SFF With Top Cover Off ...

Page 45: ...or Bank 2 As an example DIMM slots A1 B1 and C1 belong to Bank 1 while A2 B2 and C2 belong to Bank 2 Figure 8 shows how banks and channels are physically laid out on the motherboard The DIMM slots on the right channels A B and C are associated with CPU1 while the DIMM slots on the left channels D E and F are associated with CPU2 The Bank 1 blue DIMM slots are always located farther away from a CPU...

Page 46: ... a bank first Low voltage 1 35 V DIMM and standard voltage DIMM 1 5 V can be mixed in the same server Note that this causes the system BIOS to default to standard voltage operation Performance Mode See Low Voltage DIMM Considerations Low Voltage DIMM Considerations The C200 M2 server can be ordered with low voltage 1 35 V DIMMs or standard voltage 1 5 V DIMMs Note the following considerations Low ...

Page 47: ...CPU 32 GB 2 CPUs 1 x 16 GB 1 x 16 GB 1066 MHz 2 2 x 8 GB 2 x 8 GB 1333 MHz 4 2 x 4 GB 2 x 4 GB 2 x 4 GB 2 x 4 GB 1333 MHz 8 24 GB 1 CPU 48 GB 2 CPUs 3 x 8 GB 3 x 8 GB 1333 MHz 61 3 x 4 GB 3 x 4 GB 3 x 4 GB 3 x 4 GB 1333 MHz 121 32 GB 1 CPU 64 GB 2 CPUs 2 x 16 GB 2 x 16 GB 1066 MHz 4 2 x 8 GB 2 x 8 GB 2 x 8 GB 2 x 8 GB 1333 MHz 8 36 GB 1 CPU 72 GB 2 CPUs 3 x 8 GB 3 x 4 GB 3 x 8 GB 3 x 4 GB 1333 MHz...

Page 48: ...Drive Rack Mount Server 48 SUPPLEMENTAL MATERIAL Configuration Samples Figure 9 and Figure 10 on page 49 show examples of how DIMMs are populated for 1 CPU and 2 CPU systems Figure 9 Example of 24 GB DIMM Memory Combinations with One CPU ...

Page 49: ...Cisco UCS C200 M2 High Density SFF Drive Rack Mount Server SUPPLEMENTAL MATERIAL 49 Figure 10 Example of 96 GB DIMM Memory Combinations with Two CPUs ...

Page 50: ...ations Parameter Standard Rack Expansion Rack Dimensions H x W x D 78 74 x 24 x 43 38 in 2000 x 610 x 1102 mm 78 74 x 23 58 x 43 38 in 2000 x 599 x 1102 mm Dimensions H x W x D with packaging 89 x 33 x 47 in 2261 x 838 x 1194 mm 89 x 33 x 47 in 2261 x 838 x 1194 mm Distance from front mounting rail to rear mounting rail 29 2 in 741 mm 29 2 in 741 mm Weight 299 83 lb 136 kg 231 49 lb 105 kg Weight ...

Page 51: ...Cisco UCS C200 M2 High Density SFF Drive Rack Mount Server SUPPLEMENTAL MATERIAL 51 Figure 11 Cisco R42610 Rack Front view door closed Front view door open Front view door removed ...

Page 52: ... to two dozen input power cords with just one The fixed input cord connects to the power source from overhead or under floor distribution Your IT equipment is then powered by PDU outlets in the rack using short easy to manage power cords The C series severs accept the zero rack unit 0RU PDU See Figure 12 Figure 12 Zero Rack Unit PDU PID RP208 30 2P U 2 Cisco RP Series PDU models provide two 20 amp...

Page 53: ...2 High Density SFF Drive Rack Mount Server SUPPLEMENTAL MATERIAL 53 POWER SUPPLIES The C200 M2 can accommodate one or two 650 W power supplies A typical power supply is shown in Figure 13 Figure 13 C200 M2 Power Supply ...

Page 54: ...orts for a keyboard and mouse With this cable you can create a direct connection to the operating system and the BIOS running on the server The KVM cable ordering information is listed in Table 26 Figure 14 KVM Cable Table 26 KVM Cable Product ID PID PID Description 37 1016 01 KVM Cable 1 Connector to server front panel 3 VGA connector for a monitor 2 DB 9 serial connector 4 Two port USB connector...

Page 55: ...ENTAL MATERIAL 55 Motherboard USB Port The C200 M2 SFF motherboard has a general purpose USB socket as shown in Figure 15 Cisco offers a 4 GB USB drive that is compatible with this socket You can order it as a spare PID UCS USBFLSH S 4GB Figure 15 Motherboard USB Port ...

Page 56: ...Width 16 92 in 43 0 cm Depth 27 8 in 70 60 cm Front Clearance 3 in 76 mm Side Clearance 1 in 25 mm Rear Clearance 6 in 152 mm Weight 33 00 lbs 14 97 kg Table 28 UCS C200 M2 SFF Power Specifications Description Specification AC input voltage 100 to 127 VAC nominal Range 90 to 264 VAC AC input frequency 50 to 60 Hz nominal Range 47 to 63 Hz Maximum AC input current 8 A at 100 VAC Maximum AC inrush c...

Page 57: ...t_elements flash dataCenter cisco_ucs_power_calculator As an example using the calculator we can determine the approximate power for the following C200 M2 SFF server configuration Voltage 115 VAC Power Supplies 2 Processors 2 CPUs Intel Xeon 2 93 GHz X5670 Memory DIMMs 12 x 4 GB Disk Drives 4 x 1 TB PCIe Cards 2 PCIe RAID Card 0 The resulting power calculations are Idle Power 219 W 50 Load Power 3...

Page 58: ...00 m Humidity nonoperating 5 to 93 noncondensing Vibration nonoperating 2 2 Grms 10 minutes per axis on each of the three axes Shock operating Half sine 2 G 11 ms pulse 100 pulses in each direction on each of the three axes Shock nonoperating Trapezoidal 25 G two drops on each of six faces Velocity 175 inches per second on bottom face drop Velocity 90 inches per second on the other five faces Elec...

Page 59: ...ulatory Compliance Products should comply with CE Markings per directives 2004 108 EC and 2006 95 EC Safety UL 60950 1 Second Edition CAN CSA C22 2 No 60950 1 Second Edition EN 60950 1 Second Edition IEC 60950 1 Second Edition AS NZS 60950 1 GB4943 2001 EMC Emissions 47CFR Part 15 CFR 47 Class A AS NZS CISPR22 Class A CISPR22 Class A EN55022 Class A ICES003 Class A VCCI Class A EN61000 3 2 EN61000...

Page 60: ...Cisco UCS C200 M2 High Density SFF Drive Rack Mount Server 60 TECHNICAL SPECIFICATIONS ...

Reviews: