16
Cisco UCS B250 Extended Memory Blade Server Installation and Service Note
OL-22474-03
Installing and Removing the B250 M2 Air Baffle
configured with a single CPU. Cisco UCS B250 M1 servers shipped beginning July 2010 and all Cisco
UCS B250 M2 servers are automatically shipped with a baffle pre-installed. Installation requires no tools
and is shown in
Figure 7
. The baffle provides needed back pressure that allows the fans and heat sinks
to work together optimally.
Figure 7
Air Baffle (N20-BBFLB) Installation
Step 4
Carefully place the air baffle (provided through the field upgrade kit) so that two alignment holes will
align with and are engaged with the top of the standoffs.
Step 5
Replace the top cover onto the enclosure of the UCS B250 Blade Server.