background image

Page 4 of 4

Front Panel and Front Panel LEDs

LED

Color Indications

System status

A green light indicates that the system is operating normally.

A blinking green light indicates that the system is operating in a degraded condition.

DC750 (Rev 1) only: A blinking amber light indicates that the system is in a non-critical error condition.

DC750 (Rev 1) only: An amber light indicates that the system is in a critical or non-recoverable error condition.

No light indicates POST/system stop.

IMPORTANT!  - DC750 (Rev 1) only

Amber status light takes precedence over green.  When amber is on or blinking, green is off.

Power

A green light indicates there is power.

A blinking green light indicates the system is sleeping.

No light indicates there is no power.

Hard Drive Activity

A blinking green light indicates that the fixed disk drive is active.

DC750 (Rev 1) only:  An amber light indicates there is a fixed disk drive fault.

No light indicates either there is no drive activity, or the system is powered off or sleeping.

NIC Activity

A blinking green light indicates there is activity.

No light indicates there is no activity.

Management Interface LEDs

LED

Description

Left  (Link)

Indicates whether the link is up. If the LED is on, the link is up; if the LED is off, there is no link. 

Right (Activity)

Indicates activity on the port.  A blinking LED indicates activity; if the LED is off, there is no activity.

Hardware Specifications

DC750

Quick Start Guide - DC750

LEDs, SPECIFICATIONS, REGULATORY, and SECURITY

2014-5.3-2

Physical and Environmental Parameters

Parameter

DC750 (Rev 1)

DC750 (Rev 2)

Form Factor

1U

1U

Dimensions (D x W x H)

20.0” x 16.93” x 1.67” (50.8 cm x 43.0 cm x 4.24 cm)

21.8” x 17.25” x 1.67” (55.37 cm x 43.82 cm x 4.24 cm)

Max Weight

33 lbs (15 kg)

33 lbs (15 kg)

Power Supply

350 W power supply at 120 VAC 

9.5 Ampere max. at 110 Volts, 50/60 Hz 

4.75 Ampere max. at 220 volts, 50/60 Hz 

250 W power supply at 120 VAC 

6.0 Ampere max. at 110 Volts, 50/60 Hz 

3.0 Ampere max. at 220 volts, 50/60 Hz

Operating Temperature

50°F to 95°F  (10°C to 35°C) with the maximum rate of change 

not to exceed 18°F (10°C)

50°F to 95°F  (10°C to 35°C) with the maximum rate of change 

not to exceed 18°F (10°C)

Non-Operating Temperature

-40°F to +158°F (-40°C to +70°C)

-40°F to +158°F (-40°C to +70°C)

Non-Operating Humidity

90%, non-condensing at 95°F (35°C) 

90%, non-condensing at 82.4°F (28°C) 

Acoustic Noise

<7.0 dBA (rack mount) in an idle state at typical office ambient 

temperature

<7.0 dBA (rack mount) in an idle state at typical office ambient 

temperature

Operating Shock

No errors with half a sine wave shock of 2G (with 11 

millisecond duration)

No errors with half a sine wave shock of 2G (with 11 

millisecond duration)

Package Shock

Operational after 24” (61 cm) free fall; cosmetic damage may 

be present (chassis weight: 40-80 lbs / 18-36 kg)

Operational after 24” (61 cm) free fall; cosmetic damage may 

be present (chassis weight: 40-80 lbs / 18-36 kg)

Air Flow

Front to back

Front to back

ESD

+/- 12kV for air discharge and 8 K for contact

+/- 12kV for air discharge and 8 K for contact

System Cooling Requirements

1660 BTU/hour

1660 BTU/hour

Regulatory Conformance

This Sourcefire Defense Center conforms to multiple national and international standards.  For a full list of regulatory compliance, see the 

Sourcefire 3D System Installation Guide

.

Security Considerations

Before you install your Defense Center, Sourcefire recommends that you consider the following:

Locate your Defense Center in a lockable rack  within a secure location that prevents access by unauthorized personnel.

• 

Allow only trained and qualified personnel to install, replace, administer, or service the Defense Center.

• 

Always connect the management interface to a secure internal management network that is protected from unauthorized access.

• 

LEDs

A  USB port 

B  Power button 
C  System status LED 
D  Power LED
E  Fixed disk drive status LED
F  NIC 1  activity status LED
G NIC 2 activity status LED

A

G

F

B

C

D

E

DC750 (Rev 1)

A  ID button with ID LED 

B  Non-maskable interrupt button

C  NIC activity status LEDs

D  Reset button

E  Fixed disk drive status LED
F  Power button with power LED
G System status LED

DC750 (Rev 2)

A

G

F

B

C

D

E

Summary of Contents for Sourcefire Defense Center 750

Page 1: ...hout proper instruction Required items flathead and Phillips screwdrivers for the rack mounting kit laptop or monitor and keyboard to connect directly to the Defense Center Thank you for choosing Sourcefire Before installing this Defense Center download and follow the instructions in the Sourcefire Support Welcome Kit https support sourcefire com to get started with Sourcefire Support and to set u...

Page 2: ...enter because the Defense Center may attempt to use the mass storage device as a boot device Ethernet Connection to Management Interface Configure a local computer which must not be connected to the internet with the following network settings IP address 192 168 45 2 netmask 255 255 255 0 default gateway 192 168 45 1 Using an Ethernet cable connect the network interface on the local computer to th...

Page 3: ... and plug them into separate power sources Turn on the Defense Center 4 If you are using a keyboard and monitor to set up the Defense Center continue with Configuring Network Setting Using a Script in the Sourcefire 3D System Installation Guide If you are using a direct Ethernet connection to set up the Defense Center confirm that the link LED is on for both the network interface on the local comp...

Page 4: ...olts 50 60 Hz OperatingTemperature 50 F to 95 F 10 C to 35 C with the maximum rate of change not to exceed 18 F 10 C 50 F to 95 F 10 C to 35 C with the maximum rate of change not to exceed 18 F 10 C Non OperatingTemperature 40 F to 158 F 40 C to 70 C 40 F to 158 F 40 C to 70 C Non Operating Humidity 90 non condensing at 95 F 35 C 90 non condensing at 82 4 F 28 C Acoustic Noise 7 0 dBA rack mount i...

Reviews: