INSTALLATION

To install the Defense Center:

Mount the Defense Center in your rack using the mounting kit and its supplied 

1. 

instructions.

Connect to the Defense Center using either a keyboard and monitor or an Ethernet 

2. 

connection.

If you are using a keyboard and monitor to set up the Defense Center, use an 

• 

Ethernet cable now to connect the management interface to a protected network 

segment.
If you plan to perform the initial setup process by connecting a computer directly 

• 

to the Defense Center’s physical management interface, you will connect the 
management interface to the protected network when you finish setup.

Attach the power cord to the Defense Center and plug into a power source.

3. 

If your Defense Center has redundant power supplies, attach power cords to both power 
supplies and plug them into separate power sources. 

Turn on the Defense Center.

4. 

If you are using a keyboard and monitor to set up the Defense Center, continue with 

• 

Configuring Network Setting Using a Script in the 

Sourcefire 3D System Installation 

Guide.

If you are using a direct Ethernet connection to set up the Defense Center, confirm 

• 

that the link LED is on for both the network interface on the local computer and the 

management interface on the Defense Center. If the management interface and 

network interface LEDs are not lit, try using a crossover cable. For more information, 

see Cabling Inline Deployments on Copper Interfaces in the 

Sourcefire 3D System 

Installation Guide.

After you have configured network settings, make sure your Defense Center is connected 

5. 

to the protected management network with an Ethernet cable, and continue the initial 
setup with Initial Setup Page: Defense Centers in the 

Sourcefire 3D System Installation 

Guide.

Installation Procedure

Quick Start Guide - DC750

DC750

2014-5.3-2

Summary of Contents for Sourcefire Defense Center 750

Page 1: ...hout proper instruction Required items flathead and Phillips screwdrivers for the rack mounting kit laptop or monitor and keyboard to connect directly to the Defense Center Thank you for choosing Sourcefire Before installing this Defense Center download and follow the instructions in the Sourcefire Support Welcome Kit https support sourcefire com to get started with Sourcefire Support and to set u...

Page 2: ...enter because the Defense Center may attempt to use the mass storage device as a boot device Ethernet Connection to Management Interface Configure a local computer which must not be connected to the internet with the following network settings IP address 192 168 45 2 netmask 255 255 255 0 default gateway 192 168 45 1 Using an Ethernet cable connect the network interface on the local computer to th...

Page 3: ... and plug them into separate power sources Turn on the Defense Center 4 If you are using a keyboard and monitor to set up the Defense Center continue with Configuring Network Setting Using a Script in the Sourcefire 3D System Installation Guide If you are using a direct Ethernet connection to set up the Defense Center confirm that the link LED is on for both the network interface on the local comp...

Page 4: ...olts 50 60 Hz OperatingTemperature 50 F to 95 F 10 C to 35 C with the maximum rate of change not to exceed 18 F 10 C 50 F to 95 F 10 C to 35 C with the maximum rate of change not to exceed 18 F 10 C Non OperatingTemperature 40 F to 158 F 40 C to 70 C 40 F to 158 F 40 C to 70 C Non Operating Humidity 90 non condensing at 95 F 35 C 90 non condensing at 82 4 F 28 C Acoustic Noise 7 0 dBA rack mount i...