WARNING!

This Sourcefire Defense Center should be installed and maintained 

by qualified personnel only. Keep in mind the following safety 

information to avoid system damage or personal injury:
Remove all factory packaging before using the Defense Center.

• 

Provide adequate ventilation to prevent overheating.  Do not 

• 

cover or block vents, or otherwise enclose the Defense Center.  
The Defense Center must be properly grounded when 

• 

connecting power to the power outlet.

At all times, keep the chassis area free from dust.

• 

Lifting the chassis for rack installation may require two people, 

• 

as the unit is heavy.
To avoid electrical shock, do not open or remove the chassis 

• 

covers or metal parts without proper instruction.

!

Required items:

flathead and Phillips screwdrivers for the 

 

• 

rack-mounting kit 
laptop or monitor and keyboard to connect 

• 

directly to the Defense Center

Thank you for choosing Sourcefire.
Before installing this Defense Center, download and 
follow the instructions in the Sourcefire Support 
Welcome Kit (https://support.sourcefire.com) 

 

to get started with Sourcefire Support, and to set up 

your Customer Center account.

QUICK START GUIDE

Page 1 of 4

©2014 Cisco and/or its affiliates. All rights reserved.

Defense Center 750

Included items:

Sourcefire DC750 (Rev 1) or DC750 (Rev 2)

• 

one power cord

• 

one straight-through Cat 5e Ethernet cable

• 

rack-mounting kit

• 

2014-5.3-2

Front

(A)  Front Panel Controls and USB Port

Back

(

B)  Power Supply

(C)  Serial Port
(D)  VGA Port

(E)  Management Interface
(F)  Alternate eStreamer Interface
(G) USB Ports

A

G

F

B

C

D

E

DC750 (Rev 1)

DC750 (Rev 2)

Back

Front

(A)  Front Panel Controls and USB Ports

(

B)  Power Supply

(C)  Serial Port
(D)  VGA Port

(E)  Management Interface
(F)  Alternate eStreamer Interface
(G) USB Ports

A

B

C

D

G

E

F

Summary of Contents for Sourcefire Defense Center 750

Page 1: ...hout proper instruction Required items flathead and Phillips screwdrivers for the rack mounting kit laptop or monitor and keyboard to connect directly to the Defense Center Thank you for choosing Sourcefire Before installing this Defense Center download and follow the instructions in the Sourcefire Support Welcome Kit https support sourcefire com to get started with Sourcefire Support and to set u...

Page 2: ...enter because the Defense Center may attempt to use the mass storage device as a boot device Ethernet Connection to Management Interface Configure a local computer which must not be connected to the internet with the following network settings IP address 192 168 45 2 netmask 255 255 255 0 default gateway 192 168 45 1 Using an Ethernet cable connect the network interface on the local computer to th...

Page 3: ... and plug them into separate power sources Turn on the Defense Center 4 If you are using a keyboard and monitor to set up the Defense Center continue with Configuring Network Setting Using a Script in the Sourcefire 3D System Installation Guide If you are using a direct Ethernet connection to set up the Defense Center confirm that the link LED is on for both the network interface on the local comp...

Page 4: ...olts 50 60 Hz OperatingTemperature 50 F to 95 F 10 C to 35 C with the maximum rate of change not to exceed 18 F 10 C 50 F to 95 F 10 C to 35 C with the maximum rate of change not to exceed 18 F 10 C Non OperatingTemperature 40 F to 158 F 40 C to 70 C 40 F to 158 F 40 C to 70 C Non Operating Humidity 90 non condensing at 95 F 35 C 90 non condensing at 82 4 F 28 C Acoustic Noise 7 0 dBA rack mount i...