background image

Retainer clips

2

Release handles

1

The power supply modules have two status LEDs.

Description

PS OK

Description

AC OK

Output is disabled, or
input is outside operating
range.

Off

No AC input power.

Off (AC LED is off)

Power output to switch.

Green

AC input power is
present.

Green

Output has failed.

Red

Installation Guidelines

Observe these guidelines when removing or installing a power supply module:

Do not force the power supply module into the slot. This can damage the pins on the switch if they are
not aligned with the module.

A power supply that is only partially connected to the switch can disrupt the system operation.

Remove power from the power-supply module before removing or installing the module.

The power supply is hot-swappable.

Do not operate the switch with one power-supply module slot empty. For proper chassis cooling, both
module slots must be populated, with either a power supply or a blank module.

Caution

Blank faceplates and cover panels serve three important functions: they prevent exposure to hazardous
voltages and currents inside the chassis; they contain electromagnetic interference (EMI) that might disrupt
other equipment; and they direct the flow of cooling air through the chassis. Do not operate the system
unless all cards, faceplates, front covers, and rear covers are in place. Statement 1024

Warning

Do not reach into a vacant slot or chassis while you install or remove a module. Exposed circuitry could
constitute an energy hazard. Statement 206

Warning

Only trained and qualified personnel should be allowed to install, replace, or service this equipment.
Statement 1030

Warning

Catalyst 6800IA Switch Hardware Installation Guide    

   OL-30278-02

3

Power Supply Installation

Installation Guidelines

Summary of Contents for PWR-C2-1025WAC

Page 1: ...with either one or two active power supply modules You can use two AC modules or one module and a blank cover Table 1 Power Supply Model Numbers and Description Description Part Number 1025 W AC power supply module PWR C2 1025WAC The 1025 W power supply module is an autoranging unit that supports input voltages between 115 and 240 VAC All power supply modules have internal fans All switches ship w...

Page 2: ... connector 4 AC OK LED 1 Release latch 5 PS OK LED 2 Power supply 6 AC power cord retainer 3 If no power supply is installed in a power supply slot install a power supply slot cover Figure 2 Power Supply Slot Cover Catalyst 6800IA Switch Hardware Installation Guide 2 OL 30278 02 Power Supply Installation Power Supply Module Overview ...

Page 3: ...switch with one power supply module slot empty For proper chassis cooling both module slots must be populated with either a power supply or a blank module Caution Blank faceplates and cover panels serve three important functions they prevent exposure to hazardous voltages and currents inside the chassis they contain electromagnetic interference EMI that might disrupt other equipment and they direc...

Page 4: ... inward and slide the power supply out Do not leave the power supply slot open for more than 90 seconds while the switch is operating Note This unit might have more than one power supply connection All connections must be removed to de energize the unit Statement 1028 Warning Step 5 Insert the new power supply into the power supply slot and gently push it into the slot The 1025 W power supply modu...

Page 5: ...een Step 9 Repeat the steps to install a second power supply When you install the second power supply the LEDs on the power supply might blink momentarily Note Finding the Serial Number If you contact Cisco Technical Assistance you need to know the switch serial number You can also use the show version privileged EXEC command to see the switch serial number Figure 5 1025 W AC Power Supply Serial N...

Page 6: ...Catalyst 6800IA Switch Hardware Installation Guide 6 OL 30278 02 Power Supply Installation Finding the Serial Number ...