18-35
Cisco ONS 15454 Procedure Guide, R5.0
March 2007
Chapter 18 DLPs A100 to A199
DLP-A166 Change Line and Threshold Settings for the DS3-12 or DS3N-12 Cards
describes the values on the Provisioning > Elect Path Thresholds tabs for the DS-3 cards.
describes the values on the Provisioning > SONET Thresholds tabs for the DS-3 cards.
SES
Severely errored seconds
Numeric. Can be set for 15-minute or
one-day intervals. Select the bullet and click
Show Thresholds
.
LOSS
Loss of signal seconds; number of
one-second intervals containing one or
more LOS defects
Numeric. Can be set for 15-minute or
one-day intervals. Select the bullet and click
Show Thresholds
.
Table 18-8
Line Threshold Options for DS3-12 or DS3N-12 Cards (continued)
Parameter
Description
Options
Table 18-9
Electrical Path Threshold Options for DS3-12 or DS3N-12 Cards
Parameter
Description
Options
Port
(Display only.) Port number
1 to 12
EB
Errored blocks
Numeric. Can be set for 15-minute or
one-day intervals, near end or far end. Select
the bullet and click
Show Thresholds
.
BBE
Background block errors
Numeric. Can be set for 15-minute or
one-day intervals, near end or far end. Select
the bullet and click
Show Thresholds
.
ES
Errored seconds
Numeric. Can be set for 15-minute or
one-day intervals, near end or far end. Select
the bullet and click
Show Thresholds
.
SES
Severely errored seconds
Numeric. Can be set for 15-minute or
one-day intervals, near end or far end. Select
the bullet and click
Show Thresholds
.
UAS
Unavailable seconds
Numeric. Can be set for 15-minute or
one-day intervals, near end or far end. Select
the bullet and click
Show Thresholds
.
AISS
Alarm indication signal
Numeric. Can be set for 15-minute or
one-day intervals. Select the bullet and click
Show Thresholds
(DS3 Pbit: Near End
only; DS3 CPbit: Near and Far End).
Table 18-10
SONET Threshold Options for DS3-12 or DS3N-12 Cards
Parameter
Description
Options
Port
(Display only.) DS-3 ports partitioned for
STS
Line 1, STS 1, Line 2, STS 1
Line 3, STS 1, Line 4 STS 1
CV
Coding violations
Numeric. Can be set for 15-minute or
one-day intervals. Select the bullet and
click
Show Thresholds
(Near and Far
End, STS termination only).
Summary of Contents for ONS 15454 Series
Page 28: ...Tables xxviii Cisco ONS 15454 Procedure Guide R5 0 December 2004 ...
Page 44: ...Tasks xliv Cisco ONS 15454 Procedure Guide R5 0 December 2004 ...
Page 53: ...liii Cisco ONS 15454 Procedure Guide R5 0 December 2004 About this Guide Document Conventions ...
Page 55: ...lv Cisco ONS 15454 Procedure Guide R5 0 December 2004 About this Guide Document Conventions ...
Page 850: ...Index IN 22 Cisco ONS 15454 Procedure Guide R5 0 December 2004 description 4 11 remove 18 23 ...