20-21
Cisco ONS 15454 SDH Procedure Guide, R7.0
78-17194-01
Chapter 20 DLPs D300 to D399
DLP- D330 Install 120-Ohm E-1 Cables with Molex 96-Pin LFH Connectors
Use
to make the connection from the E-1 96-pin connector for Ports 22 to 42 to the external
balanced 120-ohm E-1 interfaces.
Step 2
Tighten the screws of the cable connector to the FMEC connector.
Step 3
Label all cables at each end of the connection to avoid confusion with cables that are similar in
appearance.
23
—
—
47
—
—
71
—
—
95
—
—
24
—
—
48
—
—
72
—
—
96
—
—
Table 20-6
Pinout for E-1 Interfaces on Ports 1 to 21 (continued)
Pin
No.
Signal
Name
Wire Color
Pin
No.
Signal
Name
Wire Color
Pin
No.
Signal
Name
Wire Color
Pin
No.
Signal
Name
Wire Color
Table 20-7
Pinout for E-1 Interfaces on Ports 22 to 42
Pin
No.
Signal
Name
Wire Color
Pin
No.
Signal
Name
Wire Color
Pin
No.
Signal
Name
Wire Color
Pin
No.
Signal
Name
Wire Color
1
TX 32 N
white-blue
25
RX 32 N
white-blue
49
TX 42 N
black-orange
73
RX 42 N
black-orange
2
TX 32 P
blue-white
26
RX 32 P
blue-white
50
TX 42 P
orange-black
74
RX 42 P
orange-black
3
TX 31 N
white-orange
27
RX 31 N
white-orange
51
TX 41 N
black-green
75
RX 41 N
black-green
4
TX 31 P
orange-white
28
RX 31 P
orange-white
52
TX 41 P
green-black
76
RX 41 P
green-black
5
TX 30 N
white-green
29
RX 30 N
white-green
53
TX 40 N
black-brown
77
RX 40 N
black-brown
6
TX 30 P
green-white
30
RX 30 P
green-white
54
TX 40 P
brown-black
78
RX 40 P
brown-black
7
TX 29 N
white-brown
31
RX 29 N
white-brown
55
TX 39 N
black-slate
79
RX 39 N
black-slate
8
TX 29 P
brown-white
32
RX 29 P
brown-white
56
TX 39 P
slate-black
80
RX 39 P
slate-black
9
TX 28 N
white-slate
33
RX 28 N
white-slate
57
TX 38 N
yellow-blue
81
RX 38 N
yellow-blue
10
TX 28 P
slate-white
34
RX 28 P
slate-white
58
TX 38 P
blue-yellow
82
RX 38 P
blue-yellow
11
TX 27 N
red-blue
35
RX 27 N
red-blue
59
TX 37 N
yellow-orange
83
RX 37 N
yellow-orange
12
TX 27 P
blue-red
36
RX 27 P
blue-red
60
TX 37 P
orange-yellow
84
RX 37 P
orange-yellow
13
TX 26 N
red-orange
37
RX 26 N
red-orange
61
TX 36 N
yellow-green
85
RX 36 N
yellow-green
14
TX 26 P
orange-red
38
RX 26 P
orange-red
62
TX 36 P
green-yellow
86
RX 36 P
green-yellow
15
TX 25 N
red-green
39
RX 25 N
red-green
63
TX 35 N
yellow-brown
87
RX 35 N
yellow-brown
16
TX 25 P
green-red
40
RX 25 P
green-red
64
TX 35 P
brown-yellow
88
RX 35 P
brown-yellow
17
TX 24 N
red-brown
41
RX 24 N
red-brown
65
TX 34 N
yellow-slate
89
RX 34 N
yellow-slate
18
TX 24 P
brown-red
42
RX 24 P
brown-red
66
TX 34 P
slate-yellow
90
RX 34 P
slate-yellow
19
TX 23 N
red-slate
43
RX 23 N
red-slate
67
TX 33 N
violet-blue
91
RX 33 N
violet-blue
20
TX 23 P
slate-red
44
RX 23 P
slate-red
68
TX 33 P
blue-violet
92
RX 33 P
blue-violet
21
TX 22 N
black-blue
45
RX 22 N
black-blue
69
—
—
93
—
—
22
TX 22 P
blue-black
46
RX 22 P
blue-black
70
—
—
94
—
—
23
—
—
47
—
—
71
—
—
95
—
—
24
—
—
48
—
—
72
—
—
96
—
—
Summary of Contents for ONS 15454 SDH
Page 26: ...Tables vi Cisco ONS 15454 SDH Procedure Guide R7 0 78 17194 01 ...
Page 62: ...xxii Cisco ONS 15454 SDH Procedure Guide R7 0 78 17194 01 About this Guide ...
Page 64: ...xxiv Cisco ONS 15454 SDH Procedure Guide R7 0 78 17194 01 About this Guide ...
Page 66: ...xxvi Cisco ONS 15454 SDH Procedure Guide R7 0 78 17194 01 About this Guide ...
Page 860: ...Index IN 28 Cisco ONS 15454 SDH Procedure Guide R6 0 78 17194 01 ...