Power usage is reserved for both supervisor modules regardless of whether one or both supervisor modules
are present.
Note
Use the
show environment power
command to display power usage information for the switch.
Reload a Module
You can reset a module by using the
reload module slot_number
command and specifying the module by its
slot number in the chassis.
Reloading a module disrupts traffic through the module.
Caution
To see which slots are filled with modules, use the
show inventory
command.
Note
These commands report on only software-controlled modules, such as supervisors, system controllers, line
cards, fabric modules, fan trays, and power supplies. Modules that are uncontrolled by software, such as blank
modules installed in empty slots to control airflow are not reported on.
Note
Step 1
Use the
configure terminal
command to enter the global configuration mode.
Example:
switch#
configure terminal
switch(config)#
Step 2
Use the
reload module slot_number
command to specify the slot number of the module to reset.
Example:
switch(config)#
reload module 4
This command will reload module 4. Proceed[y/n]?
[n]
y
reloading module 4 ...
switch(config)#
Rebooting a Switch
You can reboot or reload the switch by using the
reload
command without any options.
Cisco Nexus 9516 NX-OS Mode Switch Hardware Installation Guide
50
Managing the Switch
Reload a Module