c) Place your other hand under the power supply to support it while you slide it out of the chassis.
Either place the power supply on an antistatic surface or pack it in its packing materials.
d) If the power supply slot is to remain empty, install a blank power supply filler panel (part number N2200-P-BLNK).
Step 3
Install the replacement power supply as follows:
a) Holding the replacement power supply with one hand underneath the module and the other hand holding the handle,
align the back end of the power supply (the end with the electrical connections) to the open power supply slot and
slide the power supply all the way into the slot until it clicks into place.
b) Test the installation by trying to pull the power supply out of the slot without using the release latch.
If the power supply does not move out of place, it is secured in the slot. If the power supply moves, press it all the
way into the slot until it clicks in place.
Step 4
Connect the new power supply to an AC power source as follows:
a) Attach the power cable to the electrical outlet on the front of the power supply.
b) Connect the other end of the power cable to an AC power source.
• For no power redundancy, connect one power supply to one power source.
• For n+1 redundancy, connect two power supplies to one or two power sources.
• For n+n redundancy, connect each of two power supplies to a different power source.
Depending on the outlet receptacle on your power distribution unit, you might need the optional jumper
cable to connect the switch to your outlet receptacle.
Note
c) Verify that the power supply is operational by checking that the power supply OK LED is green.
Replacing a DC Power Supply
You can replace a DC power supply during operations so long as there is another power supply installed and
operating during the replacement. The switch requires only one power supply for operations, so you can hot
swap the redundant power supply during operations. If there is only one power supply installed in the chassis,
you can replace it by installing the new power supply in the open power supply slot and making it operational
before removing the other power supply. The module number can be found on the chassis.
Statement 1034—
Backplane Voltage
Hazardous voltage or energy is present on the backplane when the system is operating. Use caution when
servicing.
Warning
Before you begin
• Verify that you have an ESD wrist strap or other device to prevent ESD damage to the components that
you touch.
Cisco Nexus 3400-S Hardware Installation Guide
27
Replacing Modules
Replacing a DC Power Supply
Summary of Contents for Nexus 3400-S
Page 6: ...Cisco Nexus 3400 S Hardware Installation Guide vi Contents ...
Page 8: ...Cisco Nexus 3400 S Hardware Installation Guide viii Preface Related Documentation ...
Page 14: ...Cisco Nexus 3400 S Hardware Installation Guide 6 Preparing the Site Dust and Contaminants ...
Page 26: ...Cisco Nexus 3400 S Hardware Installation Guide 18 Installing the Chassis Starting the Switch ...
Page 42: ...Cisco Nexus 3400 S Hardware Installation Guide 34 Replacing Modules Replacing a CPU Module ...
Page 62: ...Cisco Nexus 3400 S Hardware Installation Guide 54 Spare Parts Table Spare Parts Table ...