background image

Refer to 

Cisco Technical Tips Conventions

 for more information on document conventions. 

POST  

Power-On-Self-Test (POST) is a series of diagnostic tests that run automatically when the system is 
turned on (small program contained in the BIOS). Most of the POST errors in this document are general. 
However, others are related to Compaq-specific hardware. 

POST checks these assemblies to ensure that the computer system functions properly: 

z

System ROM 

z

Keyboard 

z

Power supply 

z

System board 

z

Memory 

z

Memory expansion boards 

z

Controllers 

z

Diskette drives 

z

Hard drives 

z

Processor power modules 

z

Fans 

POST Error Message  

If POST finds an error in the system, an error condition is indicated by an audible or visual message. If 
an error code displays on the screen during POST or after you reset the system, use the instructions in 
the 

POST Error Messages

 table found in this document. 

Note: 

Many of the actions listed require you to run Diagnostics or the Compaq System Configuration 

Utility. 

These utilities can be downloaded from the Compaq/HP web site per these steps: 

1. Go to 'http://welcome.hp.com/country/us/en/support.html?pageDisplay=support'. You are then 

redirected to 

http://h20000.www2.hp.com/bizsupport/TechSupport/SoftwareDescription.jsp?

lang=en&cc=us&swItem=MTX-UNITY-I13227&jumpid=reg_R1002_USEN

 . 

 

The HP/Compaq search window appears.

Page 2 of 13

Cisco - Cisco MCS-78XX Boot Error Codes

10/2/2008

http://kbase.cisco.com/paws/servlet/ViewFile/12138/mcs_boot.xml?convertPaths=1

Summary of Contents for MCS-78 Series

Page 1: ... and hardware versions z Cisco MCS 78xx series servers z Cisco MCS 78xx Operating System OS V2000 x or later The information in this document was created from the devices in a specific lab environment All of the devices used in this document started with a cleared default configuration If your network is live make sure that you understand the potential impact of any command Conventions TAC Notice ...

Page 2: ...error in the system an error condition is indicated by an audible or visual message If an error code displays on the screen during POST or after you reset the system use the instructions in the POST Error Messages table found in this document Note Many of the actions listed require you to run Diagnostics or the Compaq System Configuration Utility These utilities can be downloaded from the Compaq H...

Page 3: ...n is corrected If the error code reappears perform the next step then run the Diagnostics program again Follow this procedure until Diagnostics no longer detects an error condition Error Code Audible Beeps Probable Source of Problem Recommended Action A Critical Error occurred prior to this power up None A catastrophic system error which cause the server to crash has been logged Run Diagnostics Re...

Page 4: ...time or date in configuration memory Run the System Configuration Utility and correct 172 Configuration Nonvolatile Memory Invalid None Nonvolatile configuration corrupt or jumper installed Run the System Configuration Utility and correct 177 Configuration Not Complete None Incomplete system configuration Run the System Configuration Utility and correct 178 Processor Configuration Invalid None Pro...

Page 5: ...ory modules installed and replace if slower than 60 ns 209 Memory Detection Failure Check Memory Installation 1 long 1 short Unable to size memory Check DIMM Installation and if error persists call the Compaq service provider 211 Cache Switch Set Incorrectly None Switch not set properly during installation or upgrade Verify switch settings 212 System Processor Failed Mapped out 1 short Processor i...

Page 6: ...System Halted None Catastrophic chipset failure Call the Compaq service provider 219 Snoop Rules SRAM Failure System Halted None Catastrophic chipset failure Call Compaq service provider 220 Cache Accelerator Slot x initialization Failed System Halted None Cache Accelerator in slot x improperly installed or bad Check Cache Accelerator installation and if properly installed replace 221 Power Fault ...

Page 7: ...rt indicated 40X Parallel Port X Address Assignment Conflict 2 short Both external and internal ports are assigned to parallel port X Run the System Configuration Utility and correct 601 Diskette Controller Error None Diskette controller circuitry failure 1 Make sure the diskette drive cables are attached 2 Replace the diskette drive and or cable 3 Replace the system board 605 Diskette Drive Type ...

Page 8: ...d Replace the failed fan 1612 Primary power supply failure 2 short Primary power supply has failed Replace power supply as soon as possible 1613 Low System Battery on power None Real time clock system battery is running low Run diagnostics Replace failed assembly as indicated 1615 Power Supply Failure Power Supply Unplugged or Power Supply Fan Failure in Bay X None A power supply has failed Replac...

Page 9: ...d Install the array enabler board 1703 SCSI cable error detected Internal SCSI cable not attached to system board connector System halted None Incorrect cabling Ensure that the integrated SCSI controller has SCSI termination attached 1720 Slot x Drive Array SMART Drive Detects Imminent Failure SCSI Port y SCSI ID x None Indicated drive has reported a SMART predictive failure condition and can fail...

Page 10: ...Slot x Drive Array Physical Drive Position Change s Detected Logical drive configuration has automatically been updated None Logical drive configuration has been updated automatically following physical drive position changes Press F1 to resume 1726 Slot x Drive Array Array Accelerator Memory Size Change Detected None Indicates array accelerator configuration has been updated automatically due to ...

Page 11: ...l Auto Reliability Monitoring has completed automatic parity consistency initialization None Normal operation This message is normal following the initial configuration of RAID 4 or RAID 5 logical drives This POST message goes away and performance of the controller improves after the parity data is initialized by ARM an automatic process that runs in the background on the controller 1730 Fixed Dis...

Page 12: ...ct 1 2008 Securing Publicly Located VoIP Phones Sep 30 2008 MCU EMP start setup over telnet Sep 30 2008 Voice Video IP Telephony When to use a tech prefix and when not to Oct 2 2008 CFWdAll Does it work by line or all lines Oct 2 2008 unable to receive voice calls Oct 2 2008 Detailed Reports on Numbers Dialed on CCM Help Oct 2 2008 Translation pattern issue Oct 2 2008 Voice Video IP Phone Services...

Page 13: ...l character escape Oct 2 2008 Get personal address book and speed dial information from call manager Sep 30 2008 CCM 4 1 3 DN Parameter on Service Sep 29 2008 Outlook VB Code to Dial CISCO IP PHONE 7960 Series Sep 29 2008 Voice Video General Maintaining the Directory in Cisco CallManager Attendant console Oct 2 2008 External Calls Transfered to External Calls Fail CCM 6 1 and h 323 Oct 2 2008 3845...