9
Note
The hostname parameter is assigned during system setup. Before you
can connect to the web interface using a hostname (http://hostname),
you must add the appliance hostname and IP address to your DNS
server.
Step 3
Click
Login
.
Command-Line Interface
Step 1
Access the command-line interface locally or remotely:
•
To access the CLI locally, set up a terminal to connect to the serial
port using 9600 bits, 8 bits, no parity, 1 stop bit (
9600, 8, N, 1
) and
flow control set to Hardware. To physically connect the terminal,
see the
“Connect to the Appliance” section on page 7
).
•
To access the CLI remotely, initiate an SSH session to the IP address
192.168.42.42
.
Step 2
Log in as
admin
with the password
ironport
.
Step 3
At the prompt, run the
systemsetup
command.
Run the System Setup Wizard
Run the System Setup Wizard to configure basic settings and enable a set of
system defaults. The System Setup Wizard starts automatically when you access
the appliance via the web-based interface (or when you run the
systemsetup
command from the command-line interface.)
Step 1
Accept the end user license agreement.
Step 2
Enter system and network information from the
“Plan the Installation”
section on page 3
.
If you need additional information about the settings, choose
Help and
Support > Online Help
.
Summary of Contents for M190