Description
Item
4 x DC pass, N(f)-N(f) lightning arrestors. Cisco PID
CGR-LA-NF-NF.
Lightning arrestors must be appropriately grounded
to infrastructure system ground designed to conduct
lightning currents to Earth ground.
This configuration assumes that the lightning arrestor
is mounted on a building or enclosure penetration
panel, and that it is interfaced on both sides with N(m)
cables.
Note
Adapter and/or Lightning Arrestor
This configuration assumes that there is an N(m) to N(m) cable
connected between the lightning arrestor and the Access Point.
For indoor cable routing, the deployment must balance the
requirements of Fire Code, Electrical Code, and any other
applicable regulations, versus RF cable type, cost, RF cable
length, and RF cable insertion loss.
Indoor Cable
Select from:
•
4 x N(m)-R/A to N(m)-STR, LMR-400-DB , 5
’
RF cable,
Cisco PID: CAB-L400-5-N-N
•
4 x N(m)-STR to N(m)-STR, LMR-400-DB , 5
’
RF cable,
Cisco PID: CAB-L400-5-N-NS
•
4 x N(m)-R/A to N(m)-STR, LMR-400-DB , 10
’
RF
cable, Cisco PID: AIR-CAB010LL-N
•
4 x N(m)-R/A to N(m)-STR, LMR-400-DB, 20 ft. cable,
Cisco PID CAB-L400-20-N-N
•
4 x N(m)-R/A to N(m)-STR, LMR-600-DB, 30 ft. cable,
Cisco PID CAB-L600-30-N-N
•
4 x N(m)-STR to N(m)-STR, LMR-400-DB, 25
’
RF cable
with petrochemical and oils resistance, Cisco PID
AIR-CAB025HZ-N
Outdoor Cable
35