Product Documentation and Compliance Information for the Cisco ISA 3000 Industrial Security Appliance

78-100733-01B0

Connecting DC Power

Warning

When you connect or disconnect the power and/or alarm connector with power applied, an electrical 
arc can occur. This could cause an explosion in hazardous area installations. Be sure that all power 
is removed from the device and any other circuits. Be sure that power cannot be accidentally turned 
on or verify that the area is nonhazardous before proceeding. 

Statement 1058

Warning

Explosion Hazard—Substitution of components may impair suitability for Class I, Division 2/Zone 2. 

Statement 1083

Warning

In device installations in a hazardous location, the DC power source could be located away from the 
vicinity of the device. Before performing any of the following procedures, locate the DC circuit to 
ensure that the power is removed and cannot be turned on accidentally, or verify that the area is 
nonhazardous before proceeding.

 Statement 1059

Warning

Installation of the equipment must comply with local and national electrical codes. 

Statement 1074

Warning

Before performing any of the following procedures, ensure that power is removed from the DC circuit. 

Statement 1003

Warning

Only trained and qualified personnel should be allowed to install, replace, or service this equipment. 

Statement 1030

Warning

A readily accessible two-poled disconnect device must be incorporated in the fixed wiring. 

Statement 1022

Step 5

Insert the ground screw into the functional ground screw opening on the 
front panel.

Attach the ring terminal to the chassis using the screw set aside in step 1.

The graphic to the right shows the proper ground connection points.

Step 6

Use a ratcheting torque screwdriver to tighten the ground screw and ring terminal to the ISA 3000 front panel to 3.5 
in-lb (0.4 N-m). The torque should not exceed 3.5 in-lb (0.4 N-m).

Step 7

Attach the other end of the ground wire to a grounded bare metal surface, such as a ground bus, a grounded DIN 
rail, or a grounded bare rack.

Summary of Contents for ISA 3000

Page 1: ... Informa tion for the Cisco ISA 3000 Industrial Security Appliance Cisco Information Related Documentation Installing the ISA 3000 Hazardous Locations Standards and Marking Strings EMC Information IMPORTANT READ ALL THE SAFETY INFORMATION BEFORE INSTALLING THE HARDWARE ...

Page 2: ...sco com Warranty Information www cisco warrantyfinder com Cisco Information Packet consisting of Cisco Limited Warranty Disclaimer of Warranty End User License Agreement and United States Federal Communications Commission Notice www cisco com en US docs general warranty English SL3DEN__ html Cisco Marketplace www cisco com pcgi bin marketplace welcome pl Cisco Product Documentation www cisco com g...

Page 3: ...ety warnings that accompanied this device Statement 1071 Warning Read the installation instructions before connecting the system to the power source Statement 1004 Warning Exposure to some chemicals could degrade the sealing properties of materials used in the sealed relay device Statement 381 Warning This product relies on the building s installation for short circuit over current protection Ensu...

Page 4: ...be a risk of electric shock from lightning Statement 1088 Caution Airflow around the device must be unrestricted To prevent the device from overheating ensure these minimum clearances Top and bottom 1 0 inches 25 mm Exposed side not connected to the module 1 0 inches 25 mm Front 1 0 inches 25 mm Contact your Cisco Technical Assistance Centre TAC if tighter spacings are required Caution This equipm...

Page 5: ...onnected to earth ground during normal use Statement 1064 Warning This equipment needs to be grounded Use a green and yellow 14 to 16 AWG ground wire to connect the host to earth ground during normal use Statement 242 Warning This equipment must be grounded Never defeat the ground conductor or operate the equipment in the absence of a suitably installed ground conductor Contact the appropriate ele...

Page 6: ...ntally or verify that the area is nonhazardous before proceeding Statement 1059 Warning Installation of the equipment must comply with local and national electrical codes Statement 1074 Warning Before performing any of the following procedures ensure that power is removed from the DC circuit Statement 1003 Warning Only trained and qualified personnel should be allowed to install replace or service...

Page 7: ... pair wires coming from each DC input power source to 0 25 inch 6 3 mm 0 02 inch 0 5 mm Do not strip more than 0 27 inch 6 8 mm of insulation from the wire Stripping more than the recommended amount of wire can leave exposed wire from the power connector after installation Step 5 Remove the two captive screws that attach the power connector to the ISA 3000 and remove the connector Step 6 On the po...

Page 8: ...he DC power source and connect the other end of the return wire to the return terminal on the DC power source When you are testing the device one power connection is sufficient If you are installing the device and are using a second power source repeat steps 4 through 8 using the second power connector 1 Step 1 Insert the power connector into the receptacle on the ISA 3000 front panel Step 2 Use a...

Page 9: ...s location installations Be sure that power is removed from the device and cannot be accidentally be turned on or verify that the area is nonhazardous before proceeding Statement 1070 Connecting to the USB Ports Note If you are connecting to the USB ports a connection to the USB ports can only be made in a non hazardous environment the USB port covers must be reinstalled before the ISA 3000 can be...

Page 10: ...ed for the hazardous locations approvals and certifications ANSI ASA 12 12 01 2013 CAN CSA C22 2 No 60079 0 11 Ed 2 CAN CSA C22 2 No 60079 15 12 Ed 1 CSA C22 2 No 213 M1987 EN 60079 0 2012 A11 2013 EN 60079 15 2010 IEC 60079 0 6th Edition IEC 60079 15 4th Edition UL 60079 0 5th Ed 2009 10 21 UL 60079 15 3rd Ed 2009 7 17 The following hazardous locations strings are provided on the ISA 3000 Class 1...

Page 11: ...11 Product Documentation and Compliance Information for the Cisco ISA 3000 Industrial Security Appliance 78 100733 01B0 This page intentionally left blank ...

Page 12: ...or registered trademarks of Cisco and or its affiliates in the U S and other countries To view a list of Cisco trademarks go to this URL www cisco com go trademarks Third party trademarks mentioned are the property of their respective owners The use of the word partner does not imply a partnership relationship between Cisco and any other company 1110R 2015 Cisco Systems Inc All rights reserved Pri...

Reviews: