Power Connectors
For detailed information about the router power supply terminal connectors (AC and DC input terminals), see
Cable and Adapter Specifications
SFP Cable
For detailed information about the SFP ports, see
Router Hardware Description, page 13
7
Clear to send (CTS)
<—
—>
8
Request to send (RTS)
—>
<—
1
The RS232 pinouts use the EIA-561 standard.
Table 5
Serial Port Specification (continued)
RS-232
1
Pin
Signal Description (Abbreviation)
DTE
DCE
Table 6
SFP Port Cabling Specification
SFP Module
Wavelength
(nm)
Cable
Type
Core size/
Cladding Size
(micron)
Modal
Bandwidth
(MHz/km)
Cable Distance
1000BASE-SX
850
MMF
62.5/125
160
722 feet (220 m)
62.5/125
200
902 feet (275 m)
50/125
400
1640 feet (500 m)
50/125
500
1804 feet (550 m)
3281 ft (1000 m)
1000BASE-LX/LH
1310
MMF
1
62.5/125
500
1804 feet (550 m)
50/125
400
1804 feet (550 m)
50/125
500
1804 feet (550 m)
SMF
G.6522
—
32,808 feet (10,000 km)
1000BASE-EX
1310
SMF
—
—
131,234 feet (40,000 km)
1000BASE-ZX
1550
SMF
G.652
2
—
43.4 to 62 miles
(70 to 100 km)
2
1000BASE-BX-U
1310
SMF
—
—
32,808 ft (10,000 m)
1000BASE-BX-D
1490
SMF
—
—
32,808 ft (10,000 m)
1
A mode-conditioning patch cord is required. Using an ordinary patch cord with MMF or 1000BASE-LX/LH SFP
modules and a short link distance can cause transceiver saturation and an elevated bit error rate (BER). When using
the LX/LH SFP module with 62.5-micron diameter MMF, you must also install a mode-conditioning patch cord
between the SFP module and the MMF cable on both the sending and receiving ends of the link. The
mode-conditioning patch cord is required for link distances greater than 984 feet (300 m).
2
1000BASE-ZX SFP modules can send data up to 62 miles (100 km) by using dispersion-shifted SMF or
low-attenuation SMF; the distance depends on the fiber quality, the number of splices, and the connectors.