Step 9

Use a screwdriver to tighten the two captive installation screws on the supervisor module. Do not over tighten the captive
installation screws.

Step 10

Check the status of the module:

a) Verify that the supervisor module STATUS LED is lit.
b) Periodically check the STATUS LED.

If the STATUS LED changes from amber to green, it means that the supervisor module has completed the boot process
successfully, and is now online.

If the STATUS LED remains amber or turns red, it means that the supervisor module has not completed the boot
process successfully, and may have encountered an error.

c) When the switch is online, enter the

show module

command. Verify that the system acknowledges the new supervisor

module and that the module status is OK.

d) If the module is not operational, reseat it. If the module is still not operational, contact your Cisco customer service

representative.

What to Do Next

Install blank slot cover in empty slots, if any, to maintain consistent airflow through the switch chassis.

Module Interfaces

The supervisor module has the following interfaces or ports: USB ports, console port, management port, and uplink ports.

To avoid electric shock, do not connect safety extra-low voltage (SELV) circuits to telephone-network
voltage (TNV) circuits. LAN ports contain SELV circuits, and WAN ports contain TNV circuits. Some
LAN and WAN ports both use RJ-45 connectors. Use caution when connecting cables.

Statement 1021

Warning

Console Ports

The supervisor engine front panel provides two types of console ports:

USB Console Port

This is the USB mini Type B Console Port.

10/100/1000 or RJ45 Console Port

This console port allows you to access the switch either locally (through a console terminal)

or remotely (through a modem). The console is an EIA/TIA-232 asynchronous, serial connection with hardware flow control
and an RJ-45 connector.

Only one of the consoles is active at a time. When a USB host (PC) is plugged into the USB console port the hardware automatically
switches over to use the USB console. Only a PC which has the necessary USB console device driver causes the USB console to
become active. Plugging in a PC that does not have the USB console driver support does not cause a switchover. When the USB
Cable is removed or the PC deactivates the USB connection, or a host is not detected on the USB console, the hardware automatically
switches to the RJ45 console port.

The console port allows you to perform the following functions:

Configure the switch from the CLI

Monitor network statistics and errors

15

Summary of Contents for Catalyst 4500 E Series Supervisor Engine 9-E

Page 1: ...Installation and Configuration Note for Cisco Catalyst 4500 E Series Supervisor Engine 9 E ...

Page 2: ... 3 10 0E and ROMMON IOS Version 15 1 1r SG14 For the latest software release requirements refer to the Cisco IOS Release Notes for the Catalyst 4500 E Series Switches at this location http www cisco com c en us support switches catalyst 4500 series switches products release notes list html Minimum software requirements Catalyst 4503 E Slot 1 only Catalyst 4506 E Slot 1 only Catalyst 4507R E Slot 3...

Page 3: ...ttelemiseen liittyvät riskit ja tutustu onnettomuuksien yleisiin ehkäisytapoihin Turvallisuusvaroitusten käännökset löytyvät laitteen mukana toimitettujen käännettyjen turvallisuusvaroitusten joukosta varoitusten lopussa näkyvien lausuntonumeroiden avulla SÄILYTÄ NÄMÄ OHJEET Varoitus IMPORTANTES INFORMATIONS DE SÉCURITÉ Ce symbole d avertissement indique un danger Vous vous trouvez dans une situat...

Page 4: ...ais Antes de iniciar a utilização de qualquer equipamento tenha conhecimento dos perigos envolvidos no manuseio de circuitos elétricos e familiarize se com as práticas habituais de prevenção de acidentes Utilize o número da instrução fornecido ao final de cada aviso para localizar sua tradução nos avisos de segurança traduzidos que acompanham este dispositivo GUARDE ESTAS INSTRUÇÕES Aviso INSTRUCC...

Page 5: ...5 ...

Page 6: ...et switch is recessed into the front panel Use a paper clip or a small pointed object to press the RESET switch Note RESET switch recessed 2 A combination push button switch and LED indicator The blue LED can be turned on either by pressing the UID switch on the front panel or through software The main purpose of the beacon LED is to enable identification from a remote location during configuratio...

Page 7: ...e while the switch is operating normally When connecting a PC to the Ethernet management port you must assign an IP address Note The port has a LINK LED to indicate port status See Cisco Catalyst 4500 E Series Supervisor Engine 9 E LEDs on page 8 For more information about the management port see Ethernet Management Port on page 16 10 100 1000 Ethernet Management Port RJ 45 connector 7 A standard ...

Page 8: ... on page 16 40 GE uplink ports 10 and 11 For physical and environmental specifications of the Supervisor Engine 9 E refer to data sheet at the following URL https www cisco com c en us products collateral switches catalyst 4500 series switches nb 09 cat 4500e sup engine ds cte en html Cisco Catalyst 4500 E Series Supervisor Engine 9 E LEDs The following figure shows the front view of the superviso...

Page 9: ... configuration or troubleshooting The ability to turn on off the LED by pressing a switch allows you to walk to the other side of a fully populated rack and identify the switch Pressing the blue beacon LED switch toggles the beacon LED on and off Blue UID LED and switch combination 2 Normal operation Green DC STATUS The DC status LED indicates the current status of the wireless daughter card 3 The...

Page 10: ...E indicates ports 1 and 2 are active 3 4 ACTIVE indicates ports 3 and 4 are active Green UPLINK ACTIVE Indicates if uplink ports 1 to 4 are active 8 Ports are not active Off The link is operational Green UPLINK STATUS Indicates the status of uplink ports 1 to 4 9 The link is disabled by user Orange The power on self test indicates a faulty port Flashing Orange No signal is detected or there is a l...

Page 11: ... handle supervisor modules use a wrist strap or other grounding device to prevent electrostatic discharge ESD damage Note Preventing Electrostatic Discharge Damage Electrostatic discharge ESD damage may occur when modules or other FRUs are improperly handled and result in intermittent or complete failure of the modules or FRUs Modules consist of printed circuit boards that are fixed in metal carri...

Page 12: ...is equipped with removable optical transceivers immediately install dust plugs into the transceiver s optical bores This prevents possible dust contamination which can affect port performance Step 4 Loosen the two captive installation screws on either end of the supervisor engine faceplate Step 5 Grasp the left and right ejector levers at either end of the supervisor engine faceplate and simultane...

Page 13: ...iguration are of the same type Procedure Step 1 Take the necessary precautions to prevent ESD damage Wear a grounded ESD wrist strap while handling the modules and keep them in ESD protective bags when they are not installed in a chassis Step 2 Ensure that you have enough clearance to accommodate any interface equipment that you will connect directly to the supervisor module ports Step 3 Remove th...

Page 14: ...rrier to support the supervisor module Step 7 Position the new module in the slot Make sure that you align the sides of the module carrier with the slot guides on each side of the chassis slot Step 8 Carefully slide the supervisor module into the slot Pivot both ejector levers in simultaneously When installed correctly The notches on both the ejector levers engage the chassis sides Both the ejecto...

Page 15: ...k do not connect safety extra low voltage SELV circuits to telephone network voltage TNV circuits LAN ports contain SELV circuits and WAN ports contain TNV circuits Some LAN and WAN ports both use RJ 45 connectors Use caution when connecting cables Statement 1021 Warning Console Ports The supervisor engine front panel provides two types of console ports USB Console Port This is the USB mini Type B...

Page 16: ...o provide additional port capacity for a fully configured switch or can reduce the need to use a chassis slot for a module These ports use hot swappable optical transceivers SFP and SFP Ports Ports are numbered 1 to 4 These ports can be configured with either SFP transceivers for 1 GE operations or SFP transceivers for 10 GE operations 1 and 10 GE uplink ports operate in full duplex mode only Both...

Page 17: ...ion and Cleaning Procedures for Fiber Optic Connections Configuring Your Supervisor Engine For information about commands that you can use to configure your supervisor engine refer to the software configuration guide for your switch under Cisco Catalyst 4500 Series Switches Configuration Guides Related Documentation For related installation and configuration information refer to the following Cata...

Page 18: ...Cisco Product Documentation as a Really Simple Syndication RSS feed and set content to be delivered directly to your desktop using a reader application The RSS feeds are a free service and Cisco currently supports RSS version 2 0 18 ...

Page 19: ...ents of the University of California NOTWITHSTANDING ANY OTHER WARRANTY HEREIN ALL DOCUMENT FILES AND SOFTWARE OF THESE SUPPLIERS ARE PROVIDED AS IS WITH ALL FAULTS CISCO AND THE ABOVE NAMED SUPPLIERS DISCLAIM ALL WARRANTIES EXPRESSED OR IMPLIED INCLUDING WITHOUT LIMITATION THOSE OF MERCHANTABILITY FITNESS FOR A PARTICULAR PURPOSE AND NONINFRINGEMENT OR ARISING FROM A COURSE OF DEALING USAGE OR TR...

Page 20: ... 2017 Cisco Systems Inc All rights reserved ...

Page 21: ...coSystemsInternationalBV Amsterdam TheNetherlands CiscoSystems USA Pte Ltd Singapore Cisco Systems Inc San Jose CA 95134 1706 USA Cisco has more than 200 offices worldwide Addresses phone numbers and fax numbers are listed on the Cisco Website at www cisco com go offices ...

Reviews: