40-5
Cisco Catalyst Blade Switch 3120 for HP Software Configuration Guide
OL-12247-01
Chapter 40 Configuring HSRP
Configuring HSRP
•
Enabling HSRP Support for ICMP Redirect Messages, page 40-11
•
Configuring HSRP Groups and Clustering, page 40-11
Default HSRP Configuration
Table 40-1
shows the default HSRP configuration.
HSRP Configuration Guidelines
Follow these guidelines when configuring HSRP:
•
HSRP can be configured on a maximum of 32 VLAN or routing interfaces.
•
In the procedures, the specified interface must be one of these Layer 3 interfaces:
–
Routed port: a physical port configured as a Layer 3 port by entering the no switchport
interface configuration command.
–
SVI: a VLAN interface created by using the interface vlan vlan_id global configuration
command and by default a Layer 3 interface.
–
Etherchannel port channel in Layer 3 mode: a port-channel logical interface created by using
the interface port-channel port-channel-number global configuration command and binding
the Ethernet interface into the channel group. For more information, see the
“Configuring
Layer 3 EtherChannels” section on page 37-14
.
•
All Layer 3 interfaces must have IP addresses assigned to them. See the
“Configuring Layer 3
Interfaces” section on page 10-21
.
Enabling HSRP
The standby ip interface configuration command activates HSRP on the configured interface. If an IP
address is specified, that address is used as the designated address for the Hot Standby group. If no IP
address is specified, the address is learned through the standby function. You must configure at least one
routing port on the cable with the designated address. Configuring an IP address always overrides
another designated address currently in use.
Table 40-1
Default HSRP Configuration
Feature
Default Setting
HSRP groups
None configured
Standby group number
0
Standby MAC address
System assigned as: 0000.0c07.acXX, where XX is the HSRP
group number
Standby priority
100
Standby delay
0 (no delay)
Standby track interface priority
10
Standby hello time
3 seconds
Standby holdtime
10 seconds