background image

 

1-2

Catalyst Switch Module 3110G, 3110X, and 3012 for IBM BladeCenter Hardware Installation Guide

OL-12192-01

Chapter 1      Product Overview

Hardware Features

Hardware Features

The Catalyst Switch Module 3110G and 3110X include the 10/100/1000 Ethernet ports or the 10-Gigabit 
Ethernet module slot, console port, StackWise Plus ports, release latch, and the switch module LEDs 
shown in 

Figure 1-1

 and described on the following pages.

Figure 1-1

Catalyst Switch Module 3110G and 3110X

Catalyst Switch 
Module 3110X

WS-CBS3110X-S

WS-CBS3110X-S-I

1 external 10-Gigabit Ethernet module 
slot, 14 internal 1000BASE-X Ethernet 
downlink ports, 1 internal 100BASE-T 
Ethernet management port, 2 
StackWise Plus ports

Catalyst Switch 
Module 3012

WS-CBS3012-IBM WS-CBS3012-IBM-I

4 external 10/100/1000BASE-T 
Ethernet ports, 14 internal 
1000BASE-X Ethernet downlink ports, 
1 internal 100BASE-T Ethernet 
management port

Table 1-1

Catalyst Switch Module 3110G, 3110X, and 3012 (continued)

Switch Model

 

 Cisco Part Number

IBM Part Number

Description

1

Catalyst Switch Module 3110G

6

10/100/1000 Ethernet ports

2

Catalyst Switch Module 3110X

7

Switch module LEDs

3

10-Gigabit Ethernet module slot

1

1.

For use with Cisco X2 transceiver modules.

8

Mode button

4

StackWise Plus ports

9

Console port

5

Release latch

201895

C
O
N
S
O
L
E

M
O
D
E

M
B
R

M
S
T

LNK

!

ACT

15

LNK

ACT

16

LNK

ACT

17

LNK

1    STACK    2

ACT

18

X2

C
O
N
S
O
L
E

M
O
D
E

M
B
R

M
S
T

!

1    STACK    2

1

4

9

6

5

8

2

7

3

Summary of Contents for Catalyst 3110G

Page 1: ...Tasman Drive San Jose CA 95134 1706 USA http www cisco com Tel 408 526 4000 800 553 NETS 6387 Fax 408 527 0883 Cisco Catalyst Switch Module 3110G 3110X and 3012 for IBM BladeCenter Hardware Installati...

Page 2: ...be required to correct any interference to radio or television communications at your own expense You can determine whether your equipment is causing interference by turning it off If the interference...

Page 3: ...1 4 Port Numbering 1 4 Internal 100BASE T Ethernet Management Port 1 4 Switch Module LEDs 1 5 StackWise Plus Ports 1 9 Console Port 1 9 Management Options 1 9 Network Configurations 1 10 C H A P T E...

Page 4: ...rformance 3 4 Resetting the Switch Module 3 4 Using the Mode Button to Reset the Switch Module 3 5 How to Replace a Failed Stack Member 3 5 A P P E N D I X A Technical Specifications A 1 A P P E N D I...

Page 5: ...switch module getting started guide the software configuration guide the command reference and the system message guide on Cisco com For information about the standard Cisco IOS Release 12 1 or 12 2...

Page 6: ...descriptions of the system messages specifically created or modified for the switch module Cisco Software Activation Document for IBM BladeCenter This document describes the supported feature sets sof...

Page 7: ...not support stacking Unless otherwise noted the term switch module refers to a standalone switch module and to a switch stack Note This product is not intended to be connected directly or indirectly b...

Page 8: ...k ports 1 internal 100BASE T Ethernet management port 2 StackWise Plus ports CatalystSwitch Module 3012 WS CBS3012 IBM WS CBS3012 IBM I 4 external 10 100 1000BASE T Ethernet ports 14 internal 1000BASE...

Page 9: ...RJ 45 connectors with Ethernet pinouts The maximum cable length is 328 feet 100 meters The 100BASE TX and 1000BASE T traffic requires Category 5 Category 5e or Category 6 unshielded twisted pair UTP...

Page 10: ...e Appendix B Connector and Cable Specifications Port Numbering Table 1 2 describes the switch module port numbering Internal 100BASE T Ethernet Management Port The internal Ethernet management port Fa...

Page 11: ...e LEDs and Mode Button 1 Stack member LED Catalyst Switch Module 3110G 8 Stack member LED 2 Mode button 9 Mode button 3 Fault stack mode LED Catalyst Switch Module 3110G Fault LED Catalyst Switch Modu...

Page 12: ...e system is receiving power and is functioning properly Table 1 3 lists the LED colors and their meanings Stack Master LED The stack master LED shows the stack master status Table 1 4 lists the LED co...

Page 13: ...3012 Stack Member LED The stack member LED is active when the switch module is stacked and you select by using the Mode button The stack member LED blinks the number of times equal to the switch stac...

Page 14: ...LED colors and their meanings Table 1 8 Catalyst Switch Module 3110G and 3012 Port LEDs Color Activity LED Description Link Status LED Description Off No activity No link or port was administratively...

Page 15: ...connect the switch module to a host For more information about the console port see the switch module getting started guide the software configuration guide and the command reference on Cisco com Mana...

Page 16: ...Catalyst 4506 Through a GUI users can configure and manage standalone switch modules and switch stacks Cisco Network Assistant is available at no cost and can be downloaded from this URL http www cisc...

Page 17: ...rs these topics Safety Warnings page 2 1 Installation Guidelines page 2 3 Box Contents page 2 3 Safety Warnings This section includes the basic installation caution and warning statements Translations...

Page 18: ...Class 1 laser product Statement 1008 Warning This unit is intended for installation in restricted access areas A restricted access area can be accessed only through the use of a special tool lock and...

Page 19: ...ce to the switch module front panel is such that Front panel indicators can be easily read Access to ports is sufficient for unrestricted cabling The X2 10GB CX4 transceiver module minimum bend radius...

Page 20: ...e switch module Figure 2 1 Note Figure 2 1 shows the IBM BC H blade enclosure as an example Your blade enclosure might look different Figure 2 1 Blade Enclosure Rear Panel View Step 3 Remove the fille...

Page 21: ...ion about the switch module LEDs Step 10 Replace the acoustic attenuation module if applicable To remove the switch module reverse the installation procedure Place either another switch module or a fi...

Page 22: ...embers We recommend that you assign the highest priority value to the switch module that you prefer to be the stack master This ensures that the switch module is re elected as stack master if a re ele...

Page 23: ...e other end of the cable into the connector of the other switch module Always use a Cisco approved StackWise Plus cable to connect the switch modules Caution The new stack member switch module restart...

Page 24: ...pter 2 Switch Module Installation Creating Switch Stacks Switch Stack Cabling Examples Figure 2 4 is an example of a recommended configuration in which two switch modules create a switch stack in a si...

Page 25: ...ide OL 12192 01 Chapter 2 Switch Module Installation Creating Switch Stacks Figure 2 5 is an example of a recommended configuration in which eight switch modules create a switch stack in eight blade e...

Page 26: ...Module Installation Creating Switch Stacks Figure 2 6 shows an example of a recommended configuration in which eight switch modules create two separate switch stacks in eight blade enclosures This co...

Page 27: ...dule observe these general precautions Do not remove the module slot cover from the 10 Gigabit Ethernet slot until you are ready to install an X2 transceiver Either a module or the module slot cover m...

Page 28: ...Installing an X2 Transceiver Module Removing a Module To remove an X2 transceiver module follow these steps Step 1 Attach an ESD preventive wrist strap to your wrist and to a bare metal surface Step...

Page 29: ...fault on the switch module With auto MDIX enabled the switch module detects the required cable type for copper Ethernet connections and configures the interface accordingly Therefore you can use eithe...

Page 30: ...2 14 Catalyst Switch Module 3110G 3110X and 3012 for IBM BladeCenter Hardware Installation Guide OL 12192 01 Chapter 2 Switch Module Installation Where to Go Next...

Page 31: ...e documentation that came with your SNMP application for details Verify Switch Module POST Results As the switch module powers on it begins the power on self test POST a series of tests that runs auto...

Page 32: ...nnection For Ethernet use Category 3 copper cable for 10 Mb s UTP connections Use Category 5 Category 5e or Category 6 UTP for 10 100 or 10 100 1000 Mb s connections For fiber optic connectors verify...

Page 33: ...rfaces privileged EXEC command to verify the port or interface error disabled disabled or shutdown status on both sides of the connection If needed re enable the port or the interface Ping End Device...

Page 34: ...the speed and duplex parameters for the ports on both ends of the connection If a remote device does not autonegotiate configure the duplex settings on the two ports to match The speed parameter can...

Page 35: ...res described in the switch module getting started guide on Cisco com For switch stacks pressing and holding the Mode button on a member switch module causes the stack to reboot It does not remove the...

Page 36: ...3 6 Catalyst Switch Module 3110G 3110X and 3012 for IBM BladeCenter Hardware Installation Guide OL 12192 01 Chapter 3 Troubleshooting How to Replace a Failed Stack Member...

Page 37: ...nmental Ranges Operating temperature 32 to 131 F 0 to 55 C Storage temperature 13 to 158 F 25 to 70 C Relative humidity 10 to 85 noncondensing Operating altitude Up to 10 000 ft 3049 m Storage altitud...

Page 38: ...A 2 Catalyst Switch Module 3110G 3110X and 3012 for IBM BladeCenter Hardware Installation Guide OL 12192 01 Appendix A Technical Specifications...

Page 39: ...tor Specifications section on page B 1 Cable and Adapter Specifications section on page B 2 Connector Specifications These sections describe the connectors used with the switch modules 10 100 1000 Por...

Page 40: ...abit Ethernet Optical Module SC Connector Figure B 3 10 Gigabit Ethernet Infiniband 4x Connector Console Port The console port uses a USB connector The supplied USB to DB 9 adapter cable is used to co...

Page 41: ...dal Bandwidth MHz km Maximum Cabling Distance X2 10GB SR 850 MMF 62 5 62 5 50 0 50 0 50 0 160 200 400 500 2000 85 feet 26 m 108 feet 33 m 217 feet 66 m 269 feet 82 m 984 feet 300 m X2 10GB LX4 1310 MM...

Page 42: ...apter Specifications Four Twisted Pair Cable Pinouts Figure B 4 and Figure B 5 show the schematics of four twisted pair cables Figure B 4 Four Twisted Pair Straight Through Cable Schematic Figure B 5...

Page 43: ...matic Identifying a Crossover Cable To identify a crossover cable compare the two modular ends of the cable Hold the cable ends side by side with the tab at the back The wire connected to the pin on t...

Page 44: ...B 6 Catalyst Switch Module 3110G 3110X and 3012 for IBM BladeCenter Hardware Installation Guide OL 12192 01 Appendix B Connector and Cable Specifications Cable and Adapter Specifications...

Page 45: ...nout B 4 identifying B 5 two twisted pair pinout B 5 recommended 2 13 StackWise Plus part numbers 1 9 straight through four twisted pair pinout B 4 two twisted pair pinout B 5 X2 transceiver module B...

Page 46: ...t stack mode 1 7 front panel 1 5 to 1 9 master 1 6 port 1 8 POST results 3 1 stack member 1 7 system power 1 6 troubleshooting with 3 1 lightning activity warning 2 2 link status troubleshooting 3 2 l...

Page 47: ...ribed 1 1 1 2 system power LED 1 6 T technical specifications A 1 Telnet and accessing the CLI 1 9 temperature operating A 1 troubleshooting bad or damaged cable 3 2 connection problems 3 2 diagnosing...

Page 48: ...Index IN 4 Catalyst Switch Module 3110G 3110X and 3012 for IBM BladeCenter Hardware Installation Guide OL 12192 01...

Reviews: