13
Step 5
From the
I/O Module Tasks
menu, click
Configuration
.
Step 6
In the
I/O Module Configuration
section, click the bay number that corresponds to the
location of the I/O module (switch module) that you are configuring. The applicable bay
number appears in the window, followed by other related I/O-module information, including
the IP address. The I/O-module information is divided into two sections:
Current IP
Configuration
and
New Static IP Configuration
(
Figure 7
)
.
Figure 7
AMM I/O Module Configuration Window
Step 7
In the
New Static IP Configuration
section, enter the new IP address, the subnet mask, and
the gateway address. Click
Save
.
The IP address for the I/O module must be on the same subnet as the management module.
The management module does not check for invalid IP addresses.