![Cisco BTS 10200 Softswitch Troubleshooting Manual Download Page 544](http://html.mh-extra.com/html/cisco/bts-10200-softswitch/bts-10200-softswitch_troubleshooting-manual_67550544.webp)
11-16
Cisco BTS 10200 Softswitch Troubleshooting Guide, Release 5.0.x
OL-8723-19
Chapter 11 Statistics Troubleshooting
Monitoring Statistics Events
Traffic and Measurements Module Application Programming Interface
Failure—Statistics (13)
The Traffic and Measurements Module Application Programming Interface Failure alarm (major)
indicates that the Traffic and Measurements module (TMM) API failed. To troubleshoot and correct the
cause of the Traffic and Measurements Module Application Programming Interface Failure alarm, refer
to the
“Traffic and Measurements Module Application Programming Interface Failure—Statistics (13)”
MDII Trunk—Statistics (14)
The MDII Trunk event serves as a warning that the calls on the MDII trunk termination are not being
successfully completed. The BTS 10200 system may take the MDII trunk out of service if it does not
take the full trunk group out of service.
Threshold Crossing Alert—Statistics (15)
The Threshold Crossing Alert alarm (minor) indicates that a threshold crossing has occurred. To
troubleshoot and correct the cause of the Threshold Crossing Alert alarm, refer to the
Crossing Alert—Statistics (15)” section on page 16
Trunk Group has Reached the MDII Alarm Threshold—Statistics (16)
The Trunk Group has Reached the MDII Alarm Threshold event serves as a warning that the trunk group
has reached the MDII alarm threshold. To correct the cause of the event, check the performance status
of the trunk group.