3-11
Cisco ASR 14000 Series Router 8-Slot Line Card Chassis Installation Guide
OL-16973-01
Chapter 3 Installing and Removing Air Circulation Components
How to Install or Remove Air Circulation Components
Step 3
Remove the cover faceplate and set it carefully aside.
Step 4
Grasp the air filter and carefully slide it from the slot.
Step 5
Set the air filter carefully aside.
What to Do Next
After performing this task, replace the front cover plates.
Installing a Power Module Air Filter
This section describes how to install a power module air filter for the Cisco ASR 14000 series 8-slot line
card chassis. For further information, see the
“About Line Card Chassis Airflow” section on page 3-1
.
For complete information on regulatory compliance and safety, see
Regulatory Compliance and Safety
Information for the Cisco ASR14000 Series Aggregation Services Router
.
Each power module has a serviceable air filter that is attached to the front of the power module and is
held in place by an air filter clip-on holder. The power module air filter faces outward from the front of
the chassis (see
).
Figure 3-8
Power Module Air Filter
Prerequisites
Before performing this task, you must first remove any front cover plates.
Caution
Never operate the Cisco ASR 14000 series 8-slot line card chassis without an air filter. Doing so can
damage the hardware.
1
Power module air filter
2
Air filter clip-on holder
POWER
OK
FLT
AC
FAIL
CB
TMP
LLM
OT
122788
2
1