If you remove a power supply from a system that has four power supplies that are connected and powered
on, the system can run only for a maximum of five minutes before shutting down. However, because the fans
and power elements are independent within the power supply, the replacement power supply does not have
to be energized within five minutes. The only requirement is that the power supply be installed in the chassis
in order to energize the fans and maintain proper system cooling.
Caution
Step 8
Grasping the power supply handles, pull the power supply from the chassis.
Step 9
Replace the DC power supply within five minutes.
What to Do Next
This completes the procedure of removing a DC power supply from the Cisco ASR 1004 Router.
Replacing the DC Power Supply in Cisco ASR 1004 Router
The color coding of the DC input power supply leads depends on the color coding of the DC power source
at your site. Typically, green or green/yellow is used for ground (GND), black is used for negative (
–
)
terminal and red is used for the positive (+) terminal. Make certain the lead color coding you choose for
the DC input power supply matches lead color coding used at the DC power source.
Note
When you install the unit, the ground connection must always be made first and disconnected last. Statement
1046
Warning
To install the DC power supply, follow these steps:
Cisco ASR 1000 Series Router Hardware Installation Guide
563
Removing and Replacing FRUs from the Cisco ASR 1000 Series Routers
Removing and Replacing a DC Power Supply in Cisco ASR 1004 Router
Summary of Contents for ASR 1001
Page 2: ... 2013 2017 Cisco Systems Inc All rights reserved ...
Page 20: ...Cisco ASR 1000 Series Router Hardware Installation Guide xx Contents ...
Page 30: ...Cisco ASR 1000 Series Router Hardware Installation Guide xxx Preface Warning Definition ...
Page 32: ...Cisco ASR 1000 Series Router Hardware Installation Guide xxxii Preface Warning Definition ...