2-47
Cisco Aironet 1530 Series Outdoor Access Point Hardware Installation Guide
OL-30864-01
Chapter 2 Installing the Access Point
Powering the Access Point
Step 4
Loosen the thread-Lock sealing nut of the cable gland by turning it counter clockwise, but do not remove
(see
).
Note
Verify that the cable gland has a rubber seal and ensure that it is not damaged.
Warning
Failure to install the Cable Gland properly will cause the cable grip to leak.
Figure 2-29
Cable Gland
Note
The cable gland accepts a cable diameter of 0.20 to 0.35 in. (0.51 to 0.89 cm).
Step 5
Insert a bare end of the DC power cable into the rounded end of the cable gland (see
pull approximately 6 inches of cable through the adapter.
Warning
When installing the DC power cable, ensure that cable gland and the rubber gasket are present and
installed properly, to avoid water leakage into the enclosure. See
Step 6
Strip the DC cable jacket back about 1 inch to expose the wires and strip the insulation about 3/8 inch
(9.5 mm) from each wire.
Step 7
Insert each wire into the two-position terminal strip (supplied), and tighten each wire using a 0.1 inch
(0.25 cm) flat screw driver (see
1
Washer (Gasket)
2
Body
3
Sealing insert
4
Clamping claw
5
Thread-lock sealing nut