background image

 

OL-30194-01 

Important Safety Instructions 

Read and Retain Instructions 

Carefully read all safety and operating instructions before operating this equipment, 
and retain them for future reference.   

 

Follow Instructions and Heed Warnings 

Follow all operating and use instructions. Pay attention to all warnings and cautions 
in the operating instructions, as well as those that are affixed to this equipment. 

 

Terminology 

The terms defined below are used in this document. The definitions given are based 
on those found in safety standards. 

Service Personnel

 - The term 

service personnel 

applies to trained and qualified 

individuals who are allowed to install, replace, or service electrical equipment. The 
service personnel are expected to use their experience and technical skills to avoid 
possible injury to themselves and others due to hazards that exist in service and 
restricted access areas. 

User and Operator

 - The terms 

user

 and 

operator

 apply to persons other than service 

personnel. 

Ground(ing) and Earth(ing)

 - The terms 

ground(ing)

 and 

earth(ing) 

are synonymous. 

This document uses ground(ing) for clarity, but it can be interpreted as having the 
same meaning as earth(ing). 

 

Electric Shock Hazard 

This equipment meets applicable safety standards. 

 

 

WARNING:

 

To reduce risk of electric shock, perform only the instructions that are 
included in the operating instructions. Refer all servicing to qualified service 
personnel only.

 

Electric shock can cause personal injury or even death. Avoid direct contact with 
dangerous voltages at all times.   

Know the following safety warnings and guidelines: 

 

Only qualified service personnel are allowed to perform equipment installation or 
replacement. 

 

Only qualified service personnel are allowed to remove chassis covers and access 
any of the components inside the chassis. 

 

Continued on next page 

Summary of Contents for 93250

Page 1: ...d in trunk and distribution applications The amplifier can be monitored via the compact transponder and the ROSA Element Management System All equalizers and pads are electronic and can be set with the handheld terminal type 91200 The plug in filters in the reverse path allow flexible choice of frequency range for both forward and reverse path Figure 1 Amplifier overview ...

Page 2: ...ves and others due to hazards that exist in service and restricted access areas User and Operator The terms user and operator apply to persons other than service personnel Ground ing and Earth ing The terms ground ing and earth ing are synonymous This document uses ground ing for clarity but it can be interpreted as having the same meaning as earth ing Electric Shock Hazard This equipment meets ap...

Page 3: ... working in confined spaces with heavy equipment Ensure this equipment is securely fastened to the mounting surface or rack where necessary to protect against damage due to any disturbance and subsequent fall Ensure the mounting surface or rack is appropriately anchored according to manufacturer s specifications Ensure the installation site meets the ventilation requirements given in the equipment...

Page 4: ...o dangerous voltages CAUTION These servicing precautions are for the guidance of qualified service personnel only To reduce the risk of electric shock do not perform any servicing other than that contained in the operating instructions unless you are qualified to do so Refer all servicing to qualified service personnel Be aware of the following general precautions and guidelines Servicing Servicin...

Page 5: ... electronic components when installing a module Fuse Replacement To replace a fuse comply with the following Disconnect the power before changing fuses Identify and clear the condition that caused the original fuse failure Always use a fuse of the correct type and rating The correct type and rating are indicated on this equipment Modifications This equipment has been designed and tested to comply ...

Page 6: ...c compatibility EMC regulatory requirements Refer to this equipment s data sheet for details about regulatory compliance approvals EMC performance is dependent upon the use of correctly shielded cables of good quality for all external connections except the power source when installing this equipment Ensure compliance with cable connector specifications and associated installation instructions whe...

Page 7: ... in units are necessary Input splitter Link type 74089 is applied if the loop port is not used Output splitter If an asymmetric splitter bridger is used the largest attenuation at the output 2 OUT 2 is obtained If only a signal at output 1 OUT 1 is requested link type 74069 is used Diplex filter Two diplex filters type 75130 with the required split frequency Use two links type 74089 if the reverse...

Page 8: ...ions may not be altered The power unit is double insulated and supplies only this single amplifier When the power unit DC voltage indicator lights the power unit is supplying correct DC voltage Remote Supply 24 to 65 V AC The amplifier can be supplied with 24 to 65 V AC either via coaxial cables max 8 A or directly to the AC input max 15 A In this case the network AC supply apparatus shall be cert...

Page 9: ...us the network is not damaged due to increased current consumption Setting up the amplifier The handheld terminal type 91200 is used to set up the amplifier Use the menu structure in the following table to navigate through the different menus Shortcuts Use the short cuts shown on the cover plate to do a fast selection of the required menu For example The output equalizer is marked with 5 By pressi...

Page 10: ... used to fine tune some values E N T E R Is used to confirm a setting or a change In the menu Copy Parameters the setting of an amplifier can be saved menu 51 and downloaded to another amplifier menu 52 Remote Supply 41 Not Connected Model Number 61 A93240 10238 Input EQ 21 5 0 dB Copy Parameters 5 Forward Gain 11 28 dB Configuration 1 Rv 25dB Reverse 3 Forward 2 Forward Freq 12 862 MHz Input Att ...

Page 11: ...ce it is inserted with a 20 dB coupler With a transponder it is possible to monitor and control different parameters in the amplifier As seen in Fig 2 the built in reverse path switch can be controlled in order to locate ingress noise in the reverse path This can be useful in the search for errors in larger networks Programming of a Compact Transponder type 91051 is done by using the handheld term...

Page 12: ...1 3845 9154 ext 109 Mexico Central America Caribbean Mexico Telephone 52 55 50 81 8425 All other Latin America countries Argentina Telephone 770 236 5662 Americas Headquarters Cisco Systems Inc 170 West Tasman Drive San Jose CA 95134 1706 USA http www cisco com Tel 408 526 4000 800 553 6387 Fax 408 527 0883 This document includes various trademarks of Cisco Systems Inc Please see the Notices secti...

Reviews: