Chapter 2 Preparing for Installation
GRP Port Connection Guidelines
2-32
Cisco 12010, Cisco 12410, and Cisco 12810 Router Installation and Configuration Guide
OL-11496-01
lists the cabling specifications for 100-Mbps transmission over
unshielded twisted-pair (UTP) cables.
lists IEEE 802.3u physical characteristics for 100BASE-TX cabling.
Table 2-6
Specifications and Connection Limits for 100-Mbps Transmission
Parameter
RJ-45
MII
Cable specification
Category 5
1
UTP, 22 - 24 AWG
2
1.
EIA/TIA-568 or EIA-TIA-568 TSB-36 compliant. Not supplied by Cisco.
2.
AWG = American Wire Gauge. This gauge is specified by the EIA/TIA-568 standard.
Category 3, 4, or 5, 150-ohm UTP or STP,
or multimode optical fiber
Cable length (max)
—
1.64 ft (0.5 m)
(MII-to-MII cable
3
)
3.
The cable between the MII port on the GRP and the appropriate transceiver.
Segment length (max)
328 ft (100 m) for 100BASE-TX 3.28 ft (1 m)
4
or 1,312 ft (400 m)
for 100BASE-FX
4.
Specifically the length between any two stations on a repeated segment.
Network length (max)
656 ft (200 m)
with 1 repeater
—
Table 2-7
IEEE 802.3u Physical Characteristics
Parameter
100BASE-TX
Data rate (Mbps)
100
Signaling method
Baseband
Segment length (max meters)
100 m between DTE and repeaters
Media
Category 5 UTP (for RJ-45) or MII
Topology
Star/hub