4.  Specification 

4.1.  General Specification 

Item Specification 

Pickup device 

Device Type 

1/1.8 type Interline Transfer B/W CCD, Sony ICX274AL

Effective Pixel Number 1628(H) x 1236 (V) 
Recommended Pixels  1620(H) x 1200(V) 
Unit Cell Size 

4.40

μ

m (H) x 4.40

μ

m (V) 

Chip Size 

8.50mm (H) x 6.80mm (V) 

Video output frequency 

Pixel Clock 

49.0908 MHz 

Horizontal Frequency  25.568KHz    Pixel Clock: 1920 CLK 

Vertical Frequency 

Full Frame Scan Mode: 1252H, approx 20 Hz 
Partial Scan Mode 1: 1029H, approx 25 Hz 
Partial Scan Mode 2: 837H, approx 30 Hz 
Partial Scan Mode 3: 629H, approx 40 Hz 

Sync. system 

Internal Sync. System 

Video output standard  PoCL or PoCL-Lite 
Resolution 

1000 TV lines 

Resolving power 

8bit / 10bit 

Sensitivity 

F5.6    400 lx (Shutter 1/20s, Gain 0dB) 

Minimum illumination  F1.4    1.0 lx (Shutter 1/20s, Gain +12dB) 
Dust or stains in   
optical system 

No dust or stain shall be detected on the testing screen with setting the camera 
aperture at F16.     

Power requirements 

DC +12V 

±

  10% (Max voltage not to exceed 15V) 

Power consumption 

2.7 W (DC +12V IN) 

Dimension 

Refer to overall dimension drawing (Clause 11) 

29mm x 29mm x 29mm (excluding projection) 

Mass Approx. 

50 

Lens mount 

C mount (Refer to overall dimension drawing ) 

Optical axis accuracy  Refer to drawing for CCD Optical Axis Accuracy

 

(Clause 10) 

Gain variable range 

-1

+12dB 

Shutter speed   
variable range 

OFF (1/20), 1/50, 1/100, 1/250, 1/500, 1/1000, 1/2000, 1/4000, 1/10000, 
1/18000, 1/40000s 

Trigger shutter mode 

Fixed Trigger Shutter Mode

  ・

Pulse Width Trigger Shutter Mode 

*Trigger pulse width shall be over 1H and less than 1/2s. 

Summary of Contents for VISION:mini VCC-G22U21APCL

Page 1: ...CC G22U21APCL Rev 900 664 32 00 2009 CIS Corporation All rights reserved UXGA B W Camera 49MHz Pixel Clock PoCL PoCL Lite VCC G22U21APCL Product Specification Operational Manual CIS Corporation Englis...

Page 2: ...esponse Representative value 7 5 Function Settings 8 6 External Connector Pin Assignment 10 7 Timing Chart 11 7 1 Horizontal Synchronous Signal Timing 11 7 2 Vertical Synchronous Signal Timing 11 7 2...

Page 3: ...ubject to fluorescent light reflections Places subject to unstable flickering etc lighting conditions Places subject to strong vibration z Remove dust or dirt on the surface of the lens with a blower...

Page 4: ...xels can be read out within approx 1 20s Interface of G22U21APCL complies with camera link standard Key Features Either PoCL or PoCL Lite interface output can be selectable Camera settings can be chan...

Page 5: ...te Resolution 1000 TV lines Resolving power 8bit 10bit Sensitivity F5 6 400 lx Shutter 1 20s Gain 0dB Minimum illumination F1 4 1 0 lx Shutter 1 20s Gain 12dB Dust or stains in optical system No dust...

Page 6: ...two conditions 1 this device may not cause harmful interference and 2 this device must accept any interference received including interference that may cause undesired operation Durability Vibration A...

Page 7: ...LVDS DVAL output LVDS HD VD input None Trigger input Polarity POSI NEGA Selectable Min Trigger Pulse width Over 1 HD Camera Link input LVDS CC1 input Camera Link connector Video output signal White Cl...

Page 8: ...de Off 1 Fixed Trigger Shutter Mode Shutter speed can be set with address 002 2 Pulse Width Trigger Shutter Mode Shutter speed can be set with trigger pulse width Scan Mode 005 0 Full Frame Scan Mode...

Page 9: ...t Mode 014 0 H Synchronous Mode 1 CLK Synchronous Mode Data Save 015 Input 083 to save address 000 014 into EEP ROM Note Please note the followings when using trigger shutter mode Re triggering at H S...

Page 10: ...nector Pin Assignment 26pins camera Link connector 12226 1100 00 PL SUMITOMO 3M Pin No Pin No 1 DC 12V 14 GND 2 X0 15 X0 3 X1 16 X1 4 X2 17 X2 5 Xclk 18 Xclk 6 X3 19 X3 7 SerTC 20 SerTC 8 SerTFG 21 Se...

Page 11: ...LVAL Signal Output Video Signal Output 1600CLK 14CLK 14CLK Active Area DVAL Signal Output 7 2 Vertical Synchronous Signal Timing 7 2 1 Normal Shutter Mode Trigger Shutter Mode OFF Recommended number o...

Page 12: ...Area 9H 9H Trigger Input LVAL output FVAL output DVAL output SP output Discharge signal Read Out signal Video Signal Exposure Time Re Trigger Input Cancell Area 7 2 2 Trigger Shutter Mode CLK Synchron...

Page 13: ...ndividual camera R Read mode Please refer to the address table of 5 Function Settings 000 255 0 Dh W Write mode C Camera mode Camera No shall consist of 6 bytes of characters numeric strings Send the...

Page 14: ...oller data Please be noted to set any dummy data at read control mode CR Be sure to input CR to confirm the end of the command 10ms should be waited to send the next command after receiving the respon...

Page 15: ...9 29 The center of effective pixels shall be Within f 0 6 to the center of lens mount Inclination of effective pixles to datum plane shall be 0 5 Dimensions from datum plane to the center of lens moun...

Page 16: ...5 999 506 00 00 3 4 5 12 20 22 Product Name Label Position M2 Size Unit mm 2 M2 Depth 3 C M o u n t 28 3 M3 Depth 3 23 7 M3 Size 4 M2 Depth 3 C Mount screws comply with ANSI ASME B1 1 1 32UN 2B Screw...

Page 17: ...f malfunction or non function of the equipment we shall be exempted from responsibility for such damages In case damage or losses are caused by failure to observe the information contained in the inst...

Page 18: ...u would like us to investigate on the cause and repair please contact your distributors you purchased from to consult and coordinate Control SW Sample software for camera control RS 232C can be downlo...

Reviews: