VCC-GM60FV11CL
Rev. 900-713-32
©2012 CIS Corporation. All rights reserved.
21
Normal Mode
2400H
~
64770H Cycle
77
~
2077ms)
1st Image
Normal Mode
-
External Trigger IN
Exposure OUT
Camera
Video Out
FVAL OUT
312H Fixed Delay
(10ms)
SOPT Mode Setting
Address
:
062 Data
:
000
・・・
45M Mode
SOPT Standby Setting
Address
:
063 Data
:
001
・・・
External Trigger
SOPT Standby Setting
Address
:
063 Data
:
000
・・・
Standby off
With receiving software trigger commands, trigger will be generated
automatically in the camera to output SOPT images.
When a trigger is input during SOPT operation, the trigger shall be ignored.
SOPT 45M Mode (shifting 9 times) (Example)
2nd Image
8th Image
9th Image
11.3.
To operate SOPT with software trigger (45M Mode)
Normal
Mode
(77ms
:
2077ms)
2400H
:
64770 HCycle
1st image
Normal Mode
SOPT 45M Mode (shifting 9times) (Example)
:
Software Trigger
Address
:
061
:
Data
:
000
Exposure OUT
Camera
Video Out
FVAL OUT
312H Fixed Delay
(10ms)
SOPT Mode
Setting
Address
:
062
:
Data
:
000
: : :
45M mode
SOPT Standby Setting
Address
:
063
:
Data
:
002
: : :
Software Trigger
SOPT Standby
Address
:
063
:
Data
:
000
: : :
Standby off
With receiving software trigger commands, trigger will be
generated automatically in the camera to output SOPT images.
8th image
2nd image
9th image
When a trigger is input during SOPT operation, the trigger shall be ignored.
(1)
With 1 trigger input, 9 images can be output at 45M mode and 25 images can be output at 125M
mode.
(2)
Partial scan mode can not be used at SOPT Mode.
(3)
Pulse width trigger mode can not be used at SOPT Mode. Shutter values should be set at the
address 002.
(4)
Set the internal trigger cycle with address 098 & 099.
11.4.
To opererate SPOT with external trigger signals (45M Mode)
(1)
With 1 trigger input, 9 images can be output at 45M mode and 25 images can be output at 125M
mode.
(2)
Partial scan mode can not be used at SOPT Mode.
(3)
Pulse width trigger mode can not be used at SOPT Mode. Shutter values should be set at the
address 002.
(4)
Set the internal trigger cycle with address 098 & 099.