5. Function Settings
Camera functions can be set with serial communications.
Function
Address Data
Gain
001
0:
0 dB: Analog Fixed Gain
1:
+6 dB: Analog Fixed Gain
2:
+12 dB: Analog Fixed Gain
3:
+15 dB: Analog Fixed Gain
4:
+21 dB: Analog Gain (+15 dB) + Digital Gain (+6 dB)
5:
Manual Gain
Interlocked right and left (Refer to Address 006)
6:
Manual Gain
Independent right and left
(Refer to Address 006 for the right. Refer to Address 008 for the left.)
E-Shutter
002
0:
1/16s(Off)
1:
1/30s
2:
1/60s
3:
1/90s
4:
1/120s
5:
1/150s
6:
1/200s
7:
1/250s
8:
1/500s
9:
1/750s
10:
1/1000s
11:
1/2000s
12:
1/5000s
13:
1/10000s
14:
1/15000s
15:
1/100000s
16:
Manual Shutter (Refer to Address 009 & 010)
Trigger Mode
004
0:
Normal Mode (Trigger Mode Off)
1:
Standard Trigger Mode (Shutter speed can be set with address 002.)
2:
Pulse Width Trigger Mode (Shutter speed can be set with trigger pulse width.)
Manual Gain
(Total & Right)
006
0
~
255:
※
When the data of address 001 is 005, Total Gain (Interlocked R and L.)
※
When the data of address 001 is 006, Right Gain (Independent R and L.)
Manual Gain (Left)
008
0
~
255:
※
When the data of address 001 is 005/006, Left Gain (Independent R and L)
Manual Shutter Control
009&010 0
~
2078:
1/16s (Off)
~
1/100,000s
※
Set the address 002 data to 016.
Address 009 MSB and address 010 LSB makes total 16 bit.
Shutter speed = (2078-(009&010)) x30.0625
μ
s +10.00
μ
s
Note: shutter speed will be 10
μ
s at 2078s (1/100,000)
Max Data=2078
Trigger Polarity
011
0:
Positive Input
1:
Negative Input
Trigger Input Select
012
0:
Camera Link Connector 12226-1100-00-PL
1:
Circular Connector HR10-7R-6PA
Output Data Select
013
0:
8bit Output Data
1:
10bit Output Data
Partial Scan Mode
015
0:
Full Frame Scan Mode
1:
Partial Scan Mode