VCC-FM60FV19CL
Rev.
900-714-31-00
©2011 CIS Corporation. All rights reserved.
12
Function Address
Data
Manual Digital Gain
(Right)
126&127 256
~
512:
256:×1(0dB)
~
512:×2(+6dB)
※
Set the data of address 001 to 004.
Manual Digital Gain (Left)
128&129 256
~
1023:
Manual White Balance R
(Right)
156&157 256
~
1023:
256:×1(0dB)
~
1023:×4(+12dB)
※
Set the data of address 003 to 004.
Manual White Balance B
(Right)
158&159 256
~
1023:
256:×1(0dB)
~
1023:×4(+12dB)
※
Set the data of address 003 to 004.
Manual White Balance R
(Left)
180&181 256
~
1023:
256:×1(0dB)
~
1023:×4(+12dB)
※
Set the data of address 003 to 004.
Manual White Balance B
(Left)
182&183 256
~
1023:
256:×1(0dB)
~
1023:×4(+12dB)
※
Set the data of address 003 to 004.
Data Save
255
Input 083 or 053 to save the data in EEP-ROM.
※
In this Specification, we describe pixel shifting technology as “SOPT: Spatial Offsetting Pickup
Technique”.
※
The data set with 2 Byte shall be set with High Byte first, then set with Low Byte. The camera rewrites
the internal resister when receiving Low Byte.