1.
Scope of Application
This is to describe VCC-F52U25CL, 3 CCD Color Camera Link Camera. All specifications contained
herein are subject to change without prior notice. Reproduction in whole or in part is prohibited.
2. Handling Precautions
The camera must not be used for any nuclear equipments or aerospace equipments with which
mechanical failure or malfunction could result in serious bodily injury or loss of human life.
Our warranty does not apply to damages or defects caused by irregular and/or abnormal use of the
product.
Please make sure to use the camera under the temperature conditions specified below. Our warranty
does not apply to damage or malfunction caused by ignoring these temperature conditions.
When the camera is used under ambient temperature over +30
℃
(86 degrees F), the temperature of
upper part or side part of the camera body should be kept under +55
℃
(131 degrees F).
Please consider proper heat dissipation in your system installation.
These recommendations apply even when camera is used under performance guaranteed temperature
and/or camera operation guaranteed temperature specified in our Specifications.
A temperature detecting sticker is enclosed for you to confirm and keep the camera body temperature
under +55
℃
. Please put the sticker on the camera as shown below and make sure that the circle for
60 is white.
With a rise in temperature, color of the sticker goes to black. The circle for 60 must be kept white.
(Please be noted that once the sticker color turns to black, it won’t be back to white again.)
50
55
60
<Example>
:
Ambient temperature
+45
℃
(113 degrees F), calm
→
Installed on an aluminum board.
(120×200×5mm)