background image

VCC-F32FV19CL  

Rev.900-586-31-00

 

©2009 CIS Corporation. All rights reserved. 

 

6

4.  Specification 

4.1.  General Specification 

Item Specification 

Remarks 

Power consumption 

5.0 W   

 

Power requirements 

DC+12V 

±

  10% (Max voltage not to exceed 15V) 

 

Operation 
environment 

(Performance guaranteed) 0

℃~

+40

 with RH 20

80% 

(Operation guaranteed)   0

 

+40

 with RH 20

80% 

No 
condensation 

Storage environment  -25

℃~

+60

 with RH 20

80%

 

 

No condensation 

Mass 215g 

 

Dimension 

Refer to overall dimension drawing (Clause

 

10) 

 

(W: 44mm

×

H : 29mm

×

D : 91mm) 

 

Lens mount 

C mount

Flange back

17.526mm

)(

fixed

 

Protruding portion shall be under 10mm. 

 

Optical axis accuracy  Under 

±

0.1mm from the center of pixel 

 

Video output signal 

Digital RAW 8bit/10bit or Digital 24bit RGB (8bit each) 

 

Pick up device 

2/3” Interline Transfer Color CCD 

 

Total Pixel number

   

  2616(H) 

×

 1960(V) 

Progressive 

Effective pixels number    2608(H) 

×

 1950(V) 

 

Unit cell size

       

3.4

μ

m(H) 

×

 3.4

μ

m(V)  Square pixel 

 

Operation Mode 

(1) Normal Mode 

12pin circular 
connector 

(2) Standard Trigger Mode (Fixed Shutter) 
(3) Pulse Width Trigger Mode 

  Can be input via camera link connector or 12pin circular connector. 

Scanning system 
Non Interlace scan 

1/10sec  Progressive scan

  (

Standard mode

 

3500 CLK 
2056 HD 

Horizontal frequency

     

20.57 KHz 

Vertical frequency

       

 10.01 Hz 

Pixel clock

         

            72 MHz 

Partial Scan 

   

             

  V Scanning Lines    Rate

   

  V. Effective lines     

Progressive Scan

   

2056 Lines      10 fps

 

     1950 Lines 

 

    Partial Scan                  1076 Lines     

 

19 fps         480 Lines 

(Initial Setting)

(Selectable 2056 line: 10fps: 1950 line

766 line: 27 fps: 15 line)   

Refer to 6.1.3. 

Sensitivity 

More than F8 at 400 lx    (at 1/10sec exposure

Gain    0dB)       

 

Min. illumination 

F1.4

 

12 lx    (at 1/10sec exposure, Gain 12dB, VS 50IRE) 

 

Summary of Contents for Vision:Elite VCC-F32FV19CL

Page 1: ...F32FV19CL Rev 900 586 31 00 English 5M Pixel Color Camera 72MHz Pixel Clock Camera Link VCC F32FV19CL Product Specification Operational Manual CIS Corporation 2009 CIS Corporation All rights reserved...

Page 2: ...t DIP SW 12 6 1 1 Shutter Speed Settings Rear panel SW1 E0 SW2 E1 SW2 E2 12 6 1 2 Operation Mode Settings Rear panel SW 4 MODE 0 SW 5 MODE 1 12 6 1 3 Partial Scan Mode Setting Switch Rear panel SW 6 S...

Page 3: ...e affected by installation conditions and or use temperature conditions Therefore we specify performance guarantee conditions of VCC F32FV19CL as below Measuring Point 2 Measuring Position There would...

Page 4: ...with a blower z Do not apply excessive force or static electricity that could damage the camera z Do not shoot direct images that are extremely bright e g light source sun etc and when camera is not...

Page 5: ...000s Video frame rates The followings are for both normal mode and trigger operation mode Progressive Scan 10fps Partial Scan 19fps is set as initial setting 10fps 27fps Trigger operation Trigger oper...

Page 6: ...t each Pick up device 2 3 Interline Transfer Color CCD Total Pixel number 2616 H 1960 V Progressive Effective pixels number 2608 H 1950 V Unit cell size 3 4 m H 3 4 m V Square pixel Operation Mode 1 N...

Page 7: ...er condition that the camera is connected 12pin circular connector CC1 input Camera Link Connector Video Output Signal Setup level 4 2 Hex to 8bit video output 00 FF Hex Shutter 1 Standard mode OFF 1...

Page 8: ...t B7 G7 Port C7 B7 RAW output 8bit output mode Rear panel switch 8 OFF 9 OFF Port bit 8bit 1 Port bit 8bit 1 Port bit 8bit 1 Port A0 D0 Port B0 Port C0 Port A1 D1 Port B1 Port C1 Port A2 D2 Port B2 Po...

Page 9: ...0 2600K 1 3200K 2 5600K 3 9000K 4 Manual White Balance Refer to address 006 007 Initial Setting 1 Trigger Mode 004 0 Normal Mode 1 Standard Trigger Mode 2 Pulse Width Trigger Mode 3 Normal Mode Initi...

Page 10: ...1 0 45 ON option Initial Setting 0 No Function 015 017 Not assigned RAW RGB 018 0 RAW 1 RGB 2 N A 3 N A Initial Setting 1 Partial Scan Starting Position 019 0 129 max 15 lines step Partial Scan Effect...

Page 11: ...ort for serial communication As an option 5 2 26pins Compact Camera Link Compatible Connector 3M Signals Specifications LVAL HD FVAL VD DVAL Composite Blanking Effective pixels area SP Signals Channel...

Page 12: ...nel SW1 E0 SW2 E1 SW2 E2 1 Normal Scan Mode 2 Standard Trigger Mode E0 E1 E2 Shutter Value E0 E1 E2 Shutter Value 1 2 3 1 2 3 OFF OFF OFF OFF 1 10 sec OFF OFF OFF 1 10 sec ON OFF OFF 1 30 sec ON OFF O...

Page 13: ...SW 6 SCAN SCAN Scanning Mode V Scanning Lines Rate V Effective Lines OFF Progressive Scan 2056 Lines 10 fps 1950 Lines ON Partial Scan Mode 1076 Lines 19 fps 480 Lines The above values are the value w...

Page 14: ...the above condition is not met the value of 129 Address 019 will be set to Address 020 Setting Example 1 Conditions Starting Position Register 019 000 Effective Line Register Address 020 Effective Li...

Page 15: ...RAW ON RGB interpolating averaged value 6 1 5 8bit 10bit Selection Switch Rear SW9 8Bit 10Bit 8bit 10bit 8bit 10bit output Switch OFF 8bit output ON 10bit output Valid only when RAW output 6 1 6 Rear...

Page 16: ...ual 0dB 12dB In Manual mode Gain is adjusted with gain potentiometer 2 White Balance setting SW100 Position A 3200K Initial Setting Position B 5600K Position C Manual In Manual mode R and B gain are a...

Page 17: ...D74LV1 GT04A Voh min 3 8 V Vol max0 55V TRG in VCC 11 pin HD74LV1 GT14A Vt max1 9 V Vt min 0 5V 470p VCC NM T 1K VD out VCC VCC 470p VCC NM T 10K 100 HD74LV1 GT126A 7 pin Vih min 2 0 V Vil max 0 8 V V...

Page 18: ...function setting 000 255 0 Dh W Write mode C Camera mode Camera No shall consist of 6 bytes of characters numeric strings Send the individual camera number code or common number code 000000 The reply...

Page 19: ...troller data Please be noted to set any dummy data at read control mode CR Be sure to input CR to confirm the end of the command 3 Setting example Set gain to 6dB with remote control function Step 1 S...

Page 20: ...ding interference that may cause undesired operation 8 Durability Item Specification Remarks Vibration resistance Acceleration 98 m s2 10 0G Vibration frequency 20 200Hz Sweep interval 300 sec Directi...

Page 21: ...pins Circular c onnector 6 pin 1 CLK 650CLK 9 2 Vertical Synchronous Timing LVAL output VIDEO output DVAL output FVAL output 1 2 3 4 5 6 7 8 9 10 2053 2052 107 108 109 90 91 92 105 106 HD output VD ou...

Page 22: ...pins Circular connector 7pin 12 pins Circular connector 10pin V Reset Trigger invalid period 9 4 Pulse Width Trigger Timing LVAL output VIDEO output FVAL output DVAL output HD output VD output 97H Tri...

Page 23: ...FF 6 M2 6 Depth 3 49 4 15 6 Product Name Label Position 0 2 26 0 1 18 0 1 24 0 1 2 Screw length from C mount lens surface shall be under 6mm And protruding portion shall be less than 10mm 1 C Mount sc...

Page 24: ...n case damage or losses are caused by failure to observe the information contained in the instructions in this product specification operation manual In case damage or losses are caused by use contrar...

Reviews: