VCC-F40U24
Rev.900-677-32-01
©2010 CIS Corporation. All rights reserved.
7
4.2. Camera Output Signal Specification
Video output
Effective output
1620(H) × 1234(V)
at full frame scan mode
Recommended
1600(H) x 1200(V)
Sync signals
Input /Output
Input signal level: 2
~
5Vp-p, TTL input
75
Ω
terminal can be selected at rear.
Automatically switched by HD recognition.
Allowable frequency deviation:
±
1%
HD/VD/WEN/SYNC output 2
~
5.0V Negative polarity output
Trigger input
Polarity:
Trigger Positive/Negative selectable with address 005.
Trigger input width: Min. 2H and over
TTL Input
Refer to the below.
VIH Min 4.0V
VIL Max 0.5V
Video signal
VS output 1.0V (p-p), Sync. Negative, 75
Ω
unbalanced, DC connect
White clip level:
840 ± 40 -30mVp-p (Excluding SYNC)
Setup level:
25 ± 10 mVp-p (Excluding SYNC)
SYNC level:
280 ± 30 mVp-p
RGB DC level:
290 ± 100 mV