VCC-SXCXP3NIR
Rev.905-0133-00
©2018 CIS Corporation. All rights reserved.
20
⑥
Input a trigger pulse to start sequence control function.
※
Notes
・
Link configuration shall be determined in advance to start each setting.
・
Restrictions on trigger input timing for sequence control operation are the same as the one for normal mode.
・
SequencerActivation shall be turned OFF once, before setting settings for sequence control.
・
With SequencerMode, UserSetSave and UserSetDefault are invalid, therefore, set them after turning power ON.
(With other settings for sequence, UserSetSave and UserSetDefault are valid).
・
If any triggers had been input to the camera, sequence starts when it is set to other than SequencerActivation OFF.
Do not input any triggers when changing SequencerActivation setting.
・
For exposure time to input to each parameter set, please refer to the maximum exposure time in the chart of
Exposure Time: Manual Shutter Mode, in
・
In case of burst mode, it stops at the last screen when sequence control is completed. And, if a trigger is input
then, it operates to capture image for one frame with the last status of the parameter set. To restart burst mode
operation, turn OFF SequencerActivation once.
・
Turn SequncerActivation OFF to return to the status before sequence control function was operated.
9.2
Trigger Mode Operation and Burst Mode
Operation Outline
This is a mode to specify Index transition flow in advance. The repeating count for each Index, the number of the Index
to be used, and Loop count can be set.
・
Trigger Mode
Index repeat count is added up every time external trigger is input, and its specified parameter set is applied to the
camera.
・
Burst Mode
It operates as the same way as internal sync mode free run. Sequence starts by a trigger, Index repeat count
increments automatically by a camera internal trigger, and the specified parameter set is applies to the camera.
Shutter
Gain
Param
#0
Shutter
Gain
Param
#1
Shutter
Gain
Param
#2
Shutter
Gain
Param
#3
Shutter
Gain
Param
#4
Shutter
Gain
Param
#8
Applying param
Index
0
Applying param
Index
1
Applying param
Index
2
Applying param
Index
3
Applying param
Index
#4
Applying param
Index
#5
Param
#0
Param
#1
Param
#0
Param
#1
Param
#4
Param
#8
200
32
100
32
60
3
1023
1
IndexLoopCount
各Indexを繰り返す回数
SequencerLoopCount
0:
無限loop
, 1
~
:
有限loop数
ActiveIndexNumber
実行するIndexの範囲
ParameterIndexNumber
各Indexとパラメータセットの紐付け
SequencerParameterSetSelector
・・・
・・・
Loop count for each Index.
0: Infinite loop, 1~: Finite loop count
Connect each Index with parameter set
Index range to be executed