VCC-FC21U19OP
Rev. 900-766-30-00
©2014 CIS Corporation. All rights reserved.
7
4.2.
Camera Output Signal Specification
(1) Video output data
Effective Video Output
2048(H) × 2048(V)
At full frame scan mode
(2) Sync. Signal output
FVAL
Pin No.3
6pins Circular Connector
(LVTTL Output)
Opt:C-LINK Output
Optical Pulse
Pin No.4
LVAL
Pin No.5
LVAL
FVAL
DVAL
SP
Optical Pulse
(3) Camera Control
Signals input
CC2
・
CC3
・
CC4
Opt:C-LINK Input
(4) Trigger Input
Polarity
Positive/Negative Selectable
Polarity is selectable
with Address 011
Pulse Width
1HD (min.)
~
Approx. 2 frames
・
2Tap Base Configuration mode
: 1HD (14.333us)
・
4Tap Medium Configuration mode
: 1HD (7.167us)
Functionally, no upper limitation is set but noises such as dark
noises and shadings might be noticeable at long time exposure.
Trigger Input
:
CC1
Camera Link input (LVDS)
:Pin No.2 6pins Circular Connector (LVTTL)
(5) Serial Communication SerTC
(Serial to Camera)
Opt:C-LINK input
SerTFG (Serial to Frame Grabber)
Opt:C-LINK output
(6) Video Signals
White Clip Level
At Digital 10bit
At Digital 8bit
: 3FFh
: FFh
Setup Level
At Digital 10bit
At Digital 8bit
: 004±004h
: 01±01h
(Condition: Gain 0dB)
Dark Shading
At Digital 10bit
At Digital 8bit
: Both horizontal and vertical
should be under ±00Fh.
: Both horizontal and vertical
should be under 03h.
(Condition: Gain 0dB)
※
2 seconds shall be waited after turning on power to get the camera operate properly.