LVAL Output

10 H

FVAL Output

DVAL Output

n H

·   ·   ·

Video Output

·   ·   ·   ·   ·   ·   ·

Exposure Time

2 H

·   ·   ·   ·   ·   ·   ·

·   ·   ·   ·   ·   ·   ·

2 H

n H (Max)

Video Output

s s+1

s+n

-1

s+n

s+n

-2

s+n

-3

s+n

-1

s+n

s+n

-2

1088 H

·   ·   ·

FVAL Output

Partial scan (vertical 1/2)  n: 544H
Manual partial scan      n: Any

· At full frame scan

· At vertical partial scan

·   ·   ·

·   ·   ·

0

1

2

271 272

815 816

1087

1086

2 H

Partial scan (vertical 1/2)  s: 272H
Manual partial scan      s: Any

1088
(The max value of vertical 
partial scan output lines)

n = 480
 Vertical partial scan output  
line set value

0 ~ 608 
Vertical partial scan
starting position setting range

s = 618 (Invalid)
 Vertical partial scan
starting position set value

s = 608 (with limitation)
Vertical partial scan
 starting position

0

608

61

8

1088

 

9.2.

 

Vertical Partial Scan 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 

 

s:

 

  Vertical partial scan starting position (address 016

017) 

 

 

 

n:

 

  Vertical partial scan output lines (address 019&020) 

Scan Mode (address:005) 

Vertical Sync. Frequency (Hz) 

0:Full frame scan mode 

1088    70.73 

1:Partial scan mode (Horizontal 1/2, Vertical 1/2)  272 

544 

  280.36 

2:Manual partial scan mode   

Any 

Any 

79.99MHz  /((vertical  partial  scan  output  line  10)  x 
(output pixel number / 2Tap)+5)) 

 

The max value of vertical partial scan starting position is limited with the formula below since vertical partial scan output   

line has priority.     

   

The max value of vertical partial scan starting position 

      =1088(The max value of vertical partial scan output line) –

 

Vertical partial scan output lines 

 
(Ex.) When 480 is set as vertical partial scan output lines, the max value of vertical partial scan starting position will be 

1088-480= 608. 
If vertical partial scan starting position is set to 618 with this time, vertical partial scan output line has priority so that 
vertical partial scan starting position shall be limited to 608. 

 
 
 
 
 
 
 
 
 
 
 

  At manual partial scan mode, manual shutter value to be set shall meet the following conditions. 

 

The set manual shutter lines

  ≦ 

Vertical partial scan output lines 

 

If the condition above is not met, shutter lines to be set will be the same number as vertical partial scan output lines. 

 

 

Summary of Contents for VCC-FC20U19PCL

Page 1: ...U19PCL Rev 900 735 33 2014 CIS Corporation All rights reserved Camera link I F 29mm cubic UXGA High Speed Color CMOS PoCL Camera VCC FC20U19PCL Product Specification Operational Manual CIS Corporation...

Page 2: ...n 10 6 Function Settings 11 7 External Connector Pin Assignment 13 7 1 26pins Mini Camera Link Connector 12226 1100 00 PL SUMITOMO 3M 13 8 Timing Chart 14 8 1 Horizontal Synchronous Signal Timing 14 8...

Page 3: ...old places operating temperature 5 to 45 Close to generators of powerful electromagnetic radiation such as radio or TV transmitters Places subject to fluorescent light reflections Places subject to un...

Page 4: ...supply voltage may cause noises on the video signals The rising time of camera power supply voltage shall be less than 10V Max 60ms Please avoid noises like chattering when rising In case of abnormal...

Page 5: ...ing the camera to a metalic part would be effective 4 Product Outline VCC FC20U19PCL is an industrial Color high speed digital video camera module utilizing a global shutter type 2 3 type 2M pixels CM...

Page 6: ...utter Speed 1 70s Gain 12dB 9 Dust or stains in optical system No dust or stain shall be detected on the testing screen with setting the camera aperture at F16 10 Power requirements DC 12V 10 Max volt...

Page 7: ...wo conditions 1 this device may not cause harmful interference and 2 this device must accept any interference received including interference that may cause undesired operation 22 Durability Vibration...

Page 8: ...3 Trigger input Polarity POSI NEGA Selectable Min width of trigger pulse 10 s Camera Link input LVDS CC1 input Camera Link connector 4 Serial Communication SerTC Serial to Camera Camera Link input LVD...

Page 9: ...70fps Mode 2Tap Interleaved Bayer Pattern GBRG at Full frame scan At manual partial scan mode Bayer Pattern changes per 1 pixel according to the set horizontal starting position value and changes per...

Page 10: ...Port A5 DA bit5 DA bit5 Port A6 DA bit6 DA bit6 Port A7 DA bit7 MSB DA bit7 Port B0 DB bit0 LSB DA bit8 Port B1 DB bit1 DA bit9 MSB Port B2 DB bit2 Not in use Port B3 DB bit3 Not in use Port B4 DB bi...

Page 11: ...nce Refer to the Address 006 007 5 255 Through Trigger Shutter Mode 004 0 Normal Shutter Mode Trigger Shutter Mode OFF 1 Fixed Trigger Shutter Mode Shutter speed can be set with address 002 2 Pulse Wi...

Page 12: ...imited according to the formula below 1088 Vertical Partial Scan output max lines Vertical Partial Scan output lines Address 005 data shalla be 002 Address 016 MSB and Address 017 LSB make 11bit in to...

Page 13: ...gnment 7 1 26pins Mini Camera Link Connector 12226 1100 00 PL SUMITOMO 3M Pin No Pin No 1 DC 12V 14 GND 2 X0 15 X0 3 X1 16 X1 4 X2 17 X2 5 Xclk 18 Xclk 6 X3 19 X3 7 SerTC 20 SerTC 8 SerTFG 21 SerTFG 9...

Page 14: ...048 5CLK 1025 CLK 1 CLK LVAL Output 10 H FVAL Output DVAL Output 1088 H 1 2 9 10 11 12 Video Output Exposure Time 2 H 1 H 1097 1098 1096 1095 1087 1088 1086 1085 1 2 1097 1098 1096 1095 2 H 2 H Min 1H...

Page 15: ...tting video signals However trigger signals for exposure to start the next video output prior to the completion of video transmission for the prior video output signals cannot be accepted If the edge...

Page 16: ...upper limitation but noises such as dark noises and shadings may be noticeable at long time exposure Triggers can be accepted even when outputting video signals However trigger signals for exposure to...

Page 17: ...tial scan starting position address 023 024 N Output pixels Output pixels 640 Horizontal partial scan output pixels set value address 027 x 10 Scan Mode address 005 S N Horizonal Sync Frequency kHz 0...

Page 18: ...equency Hz 0 Full frame scan mode 0 1088 70 73 1 Partial scan mode Horizontal 1 2 Vertical 1 2 272 544 280 36 2 Manual partial scan mode Any Any 79 99MHz vertical partial scan output line number 10 x...

Page 19: ...to the address table of 6 Function setting 000 255 0Dh W Write mode C Camera mode Camera No Please send the common code 000000 consist of 6 bytes of characters numeric strings The returned data from...

Page 20: ...CR to confirm the end of the command 11 Initial Settings Function Address Data Gain 001 0 0dB Shutter 002 0 1 70s White Balance 003 0 Through Trigger Mode 004 0 Normal Shutter Mode Trigger Shutter Mod...

Page 21: ...The center of effective pixels shall be within f 0 6 to the center of C lens mount Inclination of effective pixels Theta to datum plane shall be 0 5 Dimensions from datum plane to the center of the le...

Page 22: ...VCC FC20U19PCL Rev 900 735 33 2014 CIS Corporation All rights reserved 22 13 Dimensions...

Page 23: ...er problems resulting from use of equipment or software that is not specified In case damage or losses are caused by repair or modification conducted by the customer or any unauthorized third party su...

Reviews: