VCC-F32U29CL
Rev.
900-513-31-01
©2007 CIS Corporation. All rights reserved.
12
Function Address
Data
Remarks
Partial Scan
Effective
lines
048&049
Partial Scan Effective line number (048: V Byte 049: L Byte)
302 Line + 5 *set data (0
~
max 104)
: min 302Line
~
max822Line
Initial setting: 0, 36 (482 Line)
F, G
(5 Line/step)
Partial Scan
Starting
position
050&051
Partial Scan Starting position (050: V Byte 051: L Byte)
: min 0
~
max 185 – ( data of address 048 & 049)
Initial setting: 0, 77
F, G
(5 Line/step)
Partial Scan
Total lines
052&053
Partial Scan Total lines (052: V Byte 051: L Byte)
508 Line + 4*(Data of 048 & 049)
: min 508 Line
~
max 924 Line
Initial setting: 2,140(652 Line)
F, G
NO Function
054
Not assigned
WEN Format
055
0: VD (9H) 1: FVAL 2: EXPOSURE 3: -
F, G
Initial Setting
(0)
Output
Polarity
056
0: Standard 1: Invert
F, G
Initial Setting
(0)
Partial Scan
Blanking
057
0: Standard 1: 35 Lines Blanking
* Valid when address 005 is 1.
F, G
Initial setting
(0)
NO Function 058-062 Not assigned
Data Saving
063
To save data to EEPROM, Input“083”.
(Note) Camera inner SW104-2 shall be ON to save the data to
EEPROM.
Remark
F
・・・
F32
Only for color camera series
G ・・・ G32 Only for mono chrome camera series