8. PoE Information and Settings

 

PoE

-

Out Modes:

 

Auto

-

on mode

 

If auto

-

on is selected on a PoE

-

Out interface, then the port operates in this strict order:

 

• 

The switch checks for resistance on the connected port. If the detected resistance range is between (3k

Ω 

to 26.5k

Ω), 

the

 

power is turned on.

 

• 

When power is applied, the switch continuously checks if the overload limit is reached, or if a short circuit is detected.

 

• 

If the cable is unplugged, the port returns to the detection state, and will remain off until suitable power draw is detected.

 

 

Forced

-

on mode

 

If forced

-

on is selected, then the port operates in this strict order:

 

• 

There is no resistance check on the port. The switch applies power on pins 4,5 (+) and 7,8 (

-

), even if no cable is attached.

 

• 

When power is applied, the switch continuously checks if an overload or a short circuit is detected.

 

• 

After the cable is unplugged, the power still remains enabled on the port.

 

 

Off mode

 

If off mode is used, PoE

-

Out on the port will be turned off, no detection will take place, and the interface will behave as a sim-

ple Ethernet port.

 

 

PoE

-

Out limitations

 

It is important to check the PoE

-

Out specifications for hardware limitations because it can differ between models.

 

PoE

-

Out ports are limited with maximum amp values which are supported for a particular voltage. Usually max current will 

differ for low voltage devices (up to 30 V), and for high voltage devices (31 to 57 V).

 

PoE supplying devices also have a total current limitation which can't be exceeded, even if individual port limit allows it.

 

All CIS equipment uses the same PoE

-

Out pin polarity

 

Mode B

 

4,5 (+) and 7,8 (

-

), however other vendors can use opposite o r 

Mode A pinout on PD, this requires using a special

 

crossover cable

 

 

Enable/Disable PoE on a Specific Port

 

Select the port from the 

Interfaces

 tab. Change the PoE Out option accordingly.

 

Summary of Contents for CIS-CRS112-8P

Page 1: ...CIS CRS112 8P L2 L3 MANAGED NETWORK SWITCH PRODUCT MANUAL...

Page 2: ...ns 5 Input Power Requirements 5 4 Accessing the Web Interface 6 The Status Page 6 Set the System Identity 7 The Undo and Redo Buttons 7 Show Hide Passwords 7 Changing the Default Password 8 Rebooting...

Page 3: ...se VLAN Configuration 13 VLAN Configuration 13 Adding Ports to the VLAN s 14 8 PoE Information and Settings 15 PoE Out Modes 15 PoE Out Limitations 15 Enable Disable PoE on a Specific Port 15 9 Tools...

Page 4: ...e included power supply PoE output This device can supply PoE power to external devices from its ethernet ports The output voltage will be selected automatical ly depending on what kind of voltage the...

Page 5: ...custom LED that can be configured by CIS Disabled by default The top row LEDs indicate PoE out status A green LED indicates that the respective port uses low voltage a red LED indicates high voltage A...

Page 6: ...Open a web browser and enter the IP address in the address bar 3 To login enter the username cis and password integration 4 Integrators may use the Get TeamViewer link if remote assistance is required...

Page 7: ...hat can uniquely identify it The Identity setting can be found in the System tab in the left toolbar Undo Redo Undo and Redo buttons are located in the left toolbar You may use them to quickly undo re...

Page 8: ...e security of the device Rebooting the Device CIS discourages rebooting your switches If you are having ongoing issues with your network and suspect a reboot will help the Reboot option can be found u...

Page 9: ...require a different network address please contact CIS Services for assistance The DHCP Client tab The DHCP Client tab will present you with the IP address assigned to the switch from your router This...

Page 10: ...tting a static address perform an IP scan on the LAN to confirm available addresses see the tools section In the address field set the address you would like to use for the switch Ping the switch to c...

Page 11: ...y on all ports You can view the traffic sent and received the status of PoE PoE settings PoE priority and current being drawn by PoE devices Power Cycling To power cycle a port select the Power Cycle...

Page 12: ...re works by checking the source MAC address of received loop protect packet against MAC addresses of loop protect enabled interfaces If the match is found loop protect dis ables the interface that rec...

Page 13: ...e CIS Store Additional components are required for VLANs to function https www custom integration solutions com store cis vlan interface https www custom integration solutions com store cis additional...

Page 14: ...een created a bridge interface will be selectable on the Bridge Ports tab Select the ethernet port to link to your VLAN Select the bridge from the drop down menu This port will now access the IP addre...

Page 15: ...cks if an overload or a short circuit is detected After the cable is unplugged the power still remains enabled on the port Off mode If off mode is used PoE Out on the port will be turned off no detect...

Page 16: ...lbar UPnP CIS devices support Universal Plug and Play architecture for transparent peer to peer network connectivity of network enabled intelligent devices or appliances UPnP allows a wide range of de...

Page 17: ...The tool will attempt to scan all addresses or addresses in a specific range For example 10 100 1 0 24 Device interfaces The tool will listen to packets that are passing by and attempt to compile resu...

Page 18: ...to products that have been abused modified or disassembled Products to be repaired under this warranty must be returned to Custom Integration Solutions or a designated service center with prior notif...

Reviews: