background image

Head Office

100 Silverwater Rd, Silverwater NSW 

2128, Australia

Postal Address

PO Box 7138, Silverwater NSW 1811, 

Australia

1800 012 681   

WWW.CIRTEX.COM.AU

CIRTEX INDUSTRIES PTY LTD

DISCLAIMER

All information provided in this document is correct to 
the best knowledge Cirtex Industries Pty Ltd (“Cirtex”) 
and is given out in good faith. While every effort has 
been made to ensure the accuracy of the information 
in this catalogue, Cirtex assumes no responsibility 
for errors or omissions or for any consequences of 
reliance on this catalogue. The information presented 
herein is intended only as a general guide to the use 
of such products and no responsibility or liability is 
accepted by Cirtex for any loss or damage however 
arising, which results either directly or indirectly 
from use of such information. Cirtex has a policy of 
continuous development therefore information and 
product specifications may change without notice. This 
document is subject to copyright in its entirety. The 
contents may not be reproduced in any form, either 
in whole or in part, without written permission from 
Cirtex. Copyright 2021. All rights reserved.

Summary of Contents for T-RECS

Page 1: ...T RECS INSTALLATION GUIDELINES EROSION PROTECTION APPLICATIONS 1800 012 681 WWW CIRTEX COM AU ISO G 062 002 DATE MAY 2020 VERSION 2 ...

Page 2: ...erlapping Diagram B and securing each blanket in the beginning trench Diagram A 5 Additional horizontal blankets can be joined using a minimum 100mm overlapping or shingle style in the direction of water flow Connect the blankets by placing staples approximately 100mm apart across the width of the blankets Diagram C 6 For maximum performance a check slot should be placed at 8m 12m intervals Place ...

Page 3: ...a minimum of 100mm and secured with a row of staples approximately 1m apart See Diagram B 5 Additional vertical blankets can be joined using a minimum 100mm overlapping or shingle style See diagrams C in the direction of the water flow Connect the blankets by placing staples approximately 300mm apart across the width of the blankets 6 For maximum performance a check slot should be placed at 8m 12m...

Page 4: ...O BE PLACED 300mm ON CENTRE STAPLESTO BE PLACED 300mm ON CENTRE 300mm MINIMUM OVERLAP COMPACTED BACKFILL T RECS MATTING UP SLOPE TRENCH INSTALLATION DETAIL STEP 1 STEP 2 STAPLESTO BE PLACED 30 48cm ON CENTRE 1 46 staple m2 2 1 SLOPES 914mm 610mm 1 22m 0 58 staple m2 4 1 SLOPES 914mm 914mm 1 83m 3 2 staple m2 1 1 SLOPES 254mm 508mm 1 22m 2 93 staple m2 MED to HIGH FLOW CHANNELS 508mm 610mm 1 22m 3 ...

Page 5: ... errors or omissions or for any consequences of reliance on this catalogue The information presented herein is intended only as a general guide to the use of such products and no responsibility or liability is accepted by Cirtex for any loss or damage however arising which results either directly or indirectly from use of such information Cirtex has a policy of continuous development therefore inf...

Reviews: