CRD5378
38
DS639RD2
3.3.6
Data Capture
The
Data Capture
sub-panel collects samples from the target board and sets analysis parameters.
When the
Capture
button is pressed, the requested number of samples are collected from the target board
through the USB port. The maximum number of samples that can be collected is 1,048,576 (1M). The
number of samples per channel should be a power of two for the analysis FFT routines to work properly.
After data is collected, analysis is performed using the selected parameters and the results are displayed
on the
Analysis
panel. The selected analysis
window
,
bandwidth limit
,
full scale code
, and
full scale volt-
age
parameters can be modified for the data set currently in memory and the analysis re-run by pressing
the
REFRESH
button on the
Analysis
Panel.
Control
Description
Total Samples
Sets the total number of samples to be collected. Multichannel acquisitions split the
requested number of samples among the channels. A maximum of 1,048,576 (1M)
samples can be collected.
Window
Selects the type of analysis windowing function to be applied to the collected data
set. Used to ensure proper analysis of discontinuous data sets.
Bandwidth Limit (Hz)
Sets the frequency range over which to perform analysis, used to exclude higher-fre-
quency components. Default value of zero performs analysis for the full Nyquist fre-
quency range.
Full Scale Code
Defines the maximum positive full-scale 24-bit code from the digital filter. Used during
FFT noise analysis to set the 0 dB reference level.
Full Scale Voltage
Defines the maximum peak-to-peak input voltage for the nV/
√
Hz Spot Noise analy-
sis.
Total Captures
Sets the number of data sets to be collected and averaged together in the FFT mag-
nitude domain. The maximum number of data sets that can be averaged is 100.
Capture
Starts data collection from the target board through the USB port. After data collec-
tion, analysis is run using parameters from this sub-panel.
Remaining Captures
Indicates how many more data captures are remaining to complete the requested
number of
Total Captures
. A zero value means that the current data capture is the
last one.
Skip Samples
Sets the total number of samples to be skipped prior to data collection. A maximum
of 64K samples can be skipped
Summary of Contents for CRD5378
Page 49: ...CRD5378 DS639RD2 49 5 LAYER PLOTS ...
Page 50: ...CRD5378 50 DS639RD2 ...
Page 51: ...CRD5378 DS639RD2 51 ...
Page 52: ...CRD5378 52 DS639RD2 ...
Page 53: ...CRD5378 DS639RD2 53 ...
Page 54: ...CRD5378 54 DS639RD2 ...
Page 55: ...CRD5378 DS639RD2 55 ...
Page 56: ...CRD5378 56 DS639RD2 ...
Page 57: ...CRD5378 DS639RD2 57 6 SCHEMATICS ...
Page 58: ...CRD5378 58 DS639RD2 ...
Page 59: ...CRD5378 DS639RD2 59 ...
Page 60: ...CRD5378 60 DS639RD2 ...
Page 61: ...CRD5378 DS639RD2 61 ...
Page 62: ...CRD5378 62 DS639RD2 ...
Page 63: ...CRD5378 DS639RD2 63 ...
Page 64: ...CRD5378 64 DS639RD2 ...