CDB5480U
DS893DB5
13
1.6.3
Rogowski Coil Power Meter Example
Rogowski coil power meter can be easily connected to the CDB5480U evaluation board. Figure 8 shows
the voltage and current connections for the Rogowski sensor and its associated filter configurations.
Figure 8. Rogowski Coil Power Meter
For more information, see AN365:
Using the CS5480/84/90 Energy Measurement IC with Rogowski Coil
Current Sensors
.
IIN1-/IIN2-
IIN1+/IIN2+
GND
GND
GND
LINE
CS
5480
CDB5480U
PH
AS
E
NEU
TRA
L
J1/J12
J4
J7/J13
J8/J14
J11
J6
R5
1K
C5/C11
0.033UF
C6/C12
0.033UF
C9
0.027UF
C4
0.027UF
R11/R22
NO POP
R1/R21
100
R2/R22
100
R7 1K
R6 1K
R9/R23
NO POP
R13/R24
NO POP
R8 422K
R12 422K
R14 422K
R15 422K
R49/R52
1K
R50/R53
1K
C34/C1
0.033UF
C35/C2
0.033UF
J44/J51
J46/J52
R51/
R54
0
J45
J53/J56
J54/J55
IIN1+/IIN2+
IIN1-/IIN2-
VIN-
VIN+
Summary of Contents for CDB5480U
Page 40: ...CDB5480U 40 DS893DB5 APPENDIX B SCHEMATICS Figure 32 Schematic Analog Inputs ...
Page 43: ...CDB5480U DS893DB5 43 APPENDIX C LAYER PLOTS Figure 35 Top Silkscreen ...
Page 44: ...CDB5480U 44 DS893DB5 Figure 36 Top Routing ...
Page 45: ...CDB5480U DS893DB5 45 Figure 37 Bottom Routing ...
Page 46: ...CDB5480U 46 DS893DB5 Figure 38 Solder Paste Mask ...