Important Regulatory Information

Cirronet Product FCC ID: HSW-2411

 IC 4492A-2411

Note: 

This unit has been tested and found to comply with the limits for a Class A digital device, pursuant 

to part 15 of the FCC Rules.  These limits are designed to provide reasonable protection against harmful 
interference when the equipment is operated in a commercial environment.   This equipment generates, 
uses,   and   can   radiate   radio   frequency   energy   and,   if   not   installed   and   used   in   accordance   with   the 
instruction manual, may cause harmful interference to radio communications.  Operation of this equipment 
in a residential area is likely to cause harmful interference in which case the user will be required to correct 
the interference at their expense. 

FCC s MPE Requirements

 

Information to user/installer regarding FCC s Maximum Permissible Exposure (MPE) limits. 

Notice to users/installers using the 24 dBi parabolic dish antenna in conjunction with all Cirronet 
RF products. 

 

FCC rules limit the use of this antenna, when connected to Cirronet RF products for 

point-to-point 

applications only

.  It is the responsibility of the installer to ensure that the system is prohibited from 

being used in point-to-multipoint applications, omni-directional applications, and applications where there 
are multiple co-located intentional radiators transmitting the same information. Any other mode of 
operation using this antenna is forbidden. 

Notice to users/installers using the following fixed antennas, with Cirronet RF products:

Andrews 24dBi parabolic dish
Andrews 18dBi parabolic dish
Cushcraft 15dBi Yagi,
Mobile Mark 14dBi Corner Reflector,

 

Mobile Mark 9dBi Corner Reflector

The field strength radiated by any one of these 
antennas, when connected to Cirronet RF 
products, may exceed FCC mandated RF 
exposure limits.  FCC rules require 
professional installation of these antennas in 
such a way that the general public will not be 
closer than 2 m from the radiating aperture of 
any of these antennas.  End users of these 
systems must also be informed that RF 
exposure limits may be exceeded if personnel 
come closer than 2 m to the apertures of any of 
these antennas.  

 

Notice to users/installers using the following mobile antennas, with Cirronet RF products:

Mobile Mark 12dBi omni-directional,

 

Mobile Mark 9dBi omni-directional,

 

MaxRad 5dBi whip,
Cirronet Patch antenna,

 

Ace 2dBi dipole,

 

Mobile Mark 2dBi Stub

The field strength radiated by any one of these 
antennas, when connected to Cirronet RF 
products, may exceed FCC mandated RF 
exposure limits. FCC rules require professional 
installation of these antennas in such a way 
that the general public will not be closer than 
20 cm from the radiating aperture of any of 
these antennas. End users of these systems 
must also be informed that RF exposure limits 
may be exceeded if personnel come closer 
than 20 cm to the apertures of any of these 
antennas. 

Summary of Contents for SEM2411 /SEM2411 X

Page 1: ...SEM2411 X D DX Wireless EthernetBridge User s Guide 5375Oakbrook Parkway Norcross Georgia 30093 www cirronet com 678 684 2000...

Page 2: ...same information Any other mode of operation using this antenna is forbidden Notice to users installers using the following fixed antennas with Cirronet RF products Andrews 24dBi parabolic dish Andre...

Page 3: ...on States Norway Switzerland Use of the WIT2411 in France When used in France the WIT2411 can only be operated with the France hopping pattern selected This is accomplished by setting the pe parameter...

Page 4: ...erconnecting multi conductor cable run in approved conduit for the location The cable must be in the conduit until out of the Hazardous Location and the conduit must be gas tight so no gases can flow...

Page 5: ...iguring the SEM 12 Setting IP Addresses 12 IP Hunter Utility 12 HTML Setup 15 Console Port 18 Filtering 19 DHCP 19 SEM Operation 21 Overview 21 Security Modes 21 Point to Point Mode 21 Point to Multip...

Page 6: ......

Page 7: ...e network connection Communication between SEM products is performed using the WIT2411 over the air protocol Thus the SEM products are 802 3 compatible but not 802 11 compatible and provide 500Kbps fu...

Page 8: ...as the Master The default settings in the SEMs are sufficient to allow connection to Ethernet networks and to have the slave SEM connect with the master Other steps you may want to take include Enter...

Page 9: ...M2411 D Figures 1 2 and 3 identify the various connectors and LEDs of the SEM2411 and SEM2411D Figure 1 SEM2411 Front Panel Diagram Figure 2 SEM2411 Rear Panel Diagram 2000 2004 Cirronet Inc 3 M 2411...

Page 10: ...nd is located on the rear of the SEM The SEM is set up to use a straight through cable to connect to a PC If a straight through cable is used to connect the SEM to other devices through a hub the SEM...

Page 11: ...connector The Ethernet LEDs include LINK TXD and RXD The LINK LED lights when a valid Ethernet connection is made The SEM is set up to use a straight through cable to connect to a PC If a straight thr...

Page 12: ...dio assembly is made through the 15 pin remote radio connector on the front of the radios Digital signals rather than RF signals are sent over the connecting cable which may be up to 300 feet in lengt...

Page 13: ...SEM2411 Figure 6 SEM2411DX Front Panel Diagram Figure 7 Remote Radio Assembly 2000 2004 Cirronet Inc 7 M 2411 0007 Rev B...

Page 14: ...g the appropriate conductor color and connector hole location and inserting the pin into the hole until it clicks into place Verify the pin is locked into place by gently pulling on the conductor If a...

Page 15: ...el The figure below shows the pin numbering of the Phoenix Contact 16 pin 3 81mm Data Power connector P N1803714 The view provided is facing the side of the connector with the screw heads showing The...

Page 16: ...aight through cable is used to connect the SEM to other devices through a hub the SEM must be connected to the uplink port on the hub The SYNC IN and SYNC OUT signals are provided for special applicat...

Page 17: ...nect to a PC If a straight through cable is used to connect the SEM to other devices through a hub the SEM must be connected to the uplink port on the hub TXD and RXD are indicators of Ethernet data a...

Page 18: ...he DHCP server on the Master SEM s local network If the slave SEM cannot establish a link with the master SEM due to different network numbers or some other configuration setting the slave SEM will ne...

Page 19: ...e file iphunter exe on the SEM2411 CD The following screen will appear Click on the Search button to begin the search for Cirronet devices Only Cirronet Ethernet devices will be displayed as shown bel...

Page 20: ...uble clicking on a device with an IP address of 0 0 0 0 will bring up the following dialog box Enter the desired IP address and the default netmask will automatically be entered as shown below A new H...

Page 21: ...on in a browser window The login screen will display as shown below Enter the default Username admin and the default Password Cirronet case sensitive The password will be displayed as dots only for se...

Page 22: ...lt Route enter DNS entries or change the Outmax upload download ratio for the radio setting If the SEM2410 is to transmit data to devices not on its subnet a default router must be specified To set th...

Page 23: ...sword Verify fields Selecting Yes allows entries to be entered into the fields Details on these settings are provided in the section on Bridge Commands Bridge Connection Status This dialog displays st...

Page 24: ...gh a browser session once an IP address has been obtained and through a serial session through the console port The settings for the console port are 38400 baud 8 data bits 1 stop bit and no parity Th...

Page 25: ...iltering The SEM2411 includes provision for filtering of multicast and broadcast packets In many networks there is sufficient multicast and or broadcast packets to slow the overall performance of the...

Page 26: ...sly been entered into the SEM but a DHCP server is to be used to assign an IP address it will be necessary to set the IP address in the SEM to 0 0 0 0 using the ip command 2000 2004 Cirronet Inc 20 M...

Page 27: ...to recover lost passwords Another feature is available to limit the ability to initiate telnet sessions with the SEM The access ip add command is used to add specific IP addresses from which telnet se...

Page 28: ...ressing and registration occurs automatically and is transparent to the application A maximum of 60 slave SEMs can be connected to a master SEM The amount of data a slave can transmit depends on the n...

Page 29: ...ause the different networks are using different sequences they will transmit on the same frequency at the same time only rarely These infrequent collisions are sufficient to reduce the throughput in a...

Page 30: ...r screen echo mode ip ipaddr netmask Displays current SEM IP address Sets SEM IP address and optionally the netmask ping ipaddr Pings TCP IP host reset Resets the SEM activating changed configuration...

Page 31: ...before a response was received Continuously sends requests until a key is pressed reset Resets the SEM and loads saved parameters into active memory Also causes the SEM to reinitialize which can take...

Page 32: ...ic filtering mode filter disable turns filtering off filter bcast filters out broadcast and multicast packet while filter mcast filters out just multicast packets filter show displays the filter setti...

Page 33: ...command The default setting is disabled console disable removes the password requirement ip enable sets limitations set on initiating a telnet session to the SEM When enabled only network devices wit...

Page 34: ...1 wire ports hop Used to set the hop dwell time or the number of frequencies in the hop pattern of the radio in the SEM Master only The fcc command enables the FCC rules regarding synchronization of f...

Page 35: ...27 7 Reserved 8 2422 2447MHz France Israel 15 9 2453 2479MHz Canada Mexico 15 The frequency of the 802 11b channel avoided refers to the center frequency of the 802 11b channel slave list displays th...

Page 36: ...t 60 network 0 63 Displays current SEM network number Sets the network number for the SEM Default 0 power 0 1 Displays radio output setting 0 10dBm 1 18dBm Default Sets radio output power show Display...

Page 37: ...where the transmit power is limited to 20dBm including antenna gain Setting the transmit power to 10dBm allows up to 10dBi of antenna gain to be used show This command displays a list of the current...

Page 38: ...4X UV stabilized polycarbonate Dimensions Network Interface Unit 201 x 144 x 53 mm 7 9 x 5 7 x 2 1 Remote Radio Unit 266 x 246 x 59mm 10 5 x 9 4 x 2 3 SEM2411X only Operating Temperature Network Inte...

Page 39: ...being used to initiate the telnet session The SEM does not respond through the Console Port Check that a straight through serial cable is being used if connected to a PC If you are not using WinSEM24...

Page 40: ...er failure No suit or action shall be brought against Seller more than twelve 12 months after the related cause of action has occurred Buyer has not relied and shall not rely on any oral representatio...