8
CDP
Application notes
2�1�1� CONNECTION OF ONE INVERTER
shows the connection between the
CDP
and a single inverter.
Figure 2:Connection between a CDP and a single inverter.
2�1�2� CONNECTION OF SEVERAL INVERTERS
shows the connection between the
CDP
and several inverters.
Figure 3:Connection between a CDP and several inverters.
The communication cable between the inverters must have the following configuratio
n
:
Table 5:Communications cable connection.
Inverter 1 cable
end
Inverter 3 cable
end
Inverter n cable
end
A
A
A
B
B
B
GND
GND
GND
2.2.- INVERTER COMMUNICATION CONFIGURATION
The following describes how to use the display to configure the inverter for ensuring correct
communication with the
CDP
.
The AC and DC sides of the inverter must be connected to the mains before
it can turn on.
Consult the inverter manual if you have any doubts.
The web server or the display (only for type II communications card) can be used for configur
-
ing any parameter in the KOSTAL inverter.