Tracking Output Over Voltage Protection (OVP)
This is to protect the connected load in the event that the output voltage control
circuit malfunctions, the maximum output voltage will not exceed 30% of the
adjusted voltage value at the time of the operation.
Over Temperature Protection
When the temperature inside the power supply becomes higher than a pre-deter-
mined value, the output voltage and current of the power supply will automati-
cally decrease to zero to prevent damage to power supply. When the temperature
inside the power supply returns to normal the power supply will automatically
return to operation again.