–  4  –

Capacitance:

4n-40n-400n-4

µ

-400

µ

F

±

(5% + 10), 

±

(8% + 10) (above 100

µ

F)

(Test voltage: 3V / Test frequency: 4n-40nF 1KHz; 400n-4

µ

F

70Hz; 400

µ

F 7Hz)

Frequency:

4K-40K-400K-4000KHz

±

(0.5% + 1)

(Autoranging) (Sensitivity: 0.2Vrms minimum)

Inductance:

4m-40m-400m-40H  

±

(5% + 10)

4H  

±

(5% + 20)

(Test frequency: 4m-40mH 1KHz; 400mH-4H 70Hz; 40H 7Hz)

Transistor HFE:  0-999 HFE

Test base current: 10

µ

A / Test voltage: 3.0 

±

 0.4V

Diode :

Test current: 1.0 

±

 0.6mA / Test voltage: <3.5V

Logic:

Logic High 2.8V 

±

 0.8V / Logic Low 0.8V 

±

 0.5V

Frequency Response:  20MHz
Detectable Pulse Width:  25nS
Indication:  40msec beep at logic low

Overload Protection

Voltage:

500VDC / 350VAC - 400mV ranges
1000VDC / 750 VAC  - 4-40-400-1000/750V ranges

Current:

0.5A / 250 V Fuse for 40m-400mA ranges
10A / 600 V Fuse for 10A range (Maximum 60 seconds)

Resistance:

500VDC / 500VAC

Capacitance:

3VDC / 3VAC rms

Frequency:

500VDC / 500VAC rms

Inductance:

3VDC / 3VAC rms

Logic:

500VDC / 500VAC rms

Diode Test:

500VDC / 500VAC rms

MEASUREMENTS

Please take a few minutes to read the instructions and warnings prior to use.

1  DC VOLTAGE MEASUREMENT

!

WARNING: Maximum input is 1000V DC.

1-1

Plug the red test lead into the V

 jack and the black test lead into the

COM jack.

1-2

Set the DC/AC switch so that 

DC

 is displayed on the LCD.

1-3

Set the range switch to the desired 

V

 voltage setting. If you are unsure of

the voltage being measured, select the highest range and reduce until a
satisfactory reading is obtained.

Summary of Contents for DMR-3600

Page 1: ...OWNER S MANUAL Digital Multimeter DMR 3600 CIRCUIT TEST ELECTRONICS LTD A Division of R P Electronic Components Ltd Burnaby BC Canada V5C 5Y1 www circuittest com...

Page 2: ...letely closed 3 Disconnect test leads from equipment before removing the battery or fuse 4 Never connect unit to AC or DC powered circuits when the range switch is set to resistance diode check or con...

Page 3: ...utoranging on Frequency Polarity Automatic minus sign indicates for negative polarity Measuring Rate 2 5 times second Input Impedance 10 M DCV ACV Operation Temp 0 to 45 C Storage Temp 15 to 50 C Fuse...

Page 4: ...C 400mV ranges 1000VDC 750 VAC 4 40 400 1000 750V ranges Current 0 5A 250 V Fuse for 40m 400mA ranges 10A 600 V Fuse for 10A range Maximum 60 seconds Resistance 500VDC 500VAC Capacitance 3VDC 3VAC rms...

Page 5: ...o not connect to the circuit for more than 60 seconds and wait 10 minutes between 10A meas urements 3 1 PlugtheredtestleadintothemAjackandtheblacktestleadintotheCOM jack If the current being measured...

Page 6: ...to the circuit being measured and disconnect test leads NOTE If changing range switch to or from the 10A position first disconnect power and test leads from the circuit being tested Repeat the above...

Page 7: ...to 7 1 Plug the red test lead into the V jack and the black test lead into the COM jack 7 2 Set the range switch to the setting 7 3 Connect the probes to the device you want to test Note the meter rea...

Page 8: ...t the capacitor leads are inserted into opposing sockets 10 3 Read the displayed capacitor value 11 INDUCTANCE MEASUREMENT 11 1 SettherangeswitchtothedesiredHInductancesetting Ifyouareunsure of the va...

Page 9: ...connectorandreplacewithanew9Vbattery 13 5 Replace the cover and cover screws 14 FUSE REPLACEMENT WARNING Disconnect both test leads from any equipment before removing back cover Do not use the meter w...

Page 10: ...xplana tion of the defect to In Canada Circuit Test Electronics A Division of R P Electronic Components Ltd 2060 Rosser Ave Burnaby BC V5C 5Y1 Any product which has been subjected to misuse or acciden...

Reviews: