Circuit-test DMR-3600 Owner'S Manual Download Page 10

–  10  –

ACCESSORIES

Test Leads (set):   

TL-125

Holster (optional):   

CS-3600H

Fuses:   

AGX 0.5A/250V 

&

 TUE 10A/600V

LIMITED WARRANTY

Circuit-Test Electronics warrants to the original purchaser that this product
be free of defect in material or workmanship for a period of 2 years from the
date of purchase. If this product requires warranty service, return the unit
(freight prepaid), together with your dated proof of purchase and explana-
tion of the defect to:

In Canada: Circuit-Test Electronics

(A Division of R.P. Electronic Components Ltd.)
2060 Rosser Ave
Burnaby, BC, V5C 5Y1

Any product which has been subjected to misuse or accidental damage is
excluded from the warranty. Except as stated above, Circuit-Test Electron-
ics makes no promises or warranties either expressed or implied including
warranties of merchantability or the fitness for any particular purpose. This
warranty gives you specific legal rights and you may have other rights which
vary under the laws of the various countries, states or provinces in which
Circuit-Test Electronics operates.

Summary of Contents for DMR-3600

Page 1: ...OWNER S MANUAL Digital Multimeter DMR 3600 CIRCUIT TEST ELECTRONICS LTD A Division of R P Electronic Components Ltd Burnaby BC Canada V5C 5Y1 www circuittest com...

Page 2: ...letely closed 3 Disconnect test leads from equipment before removing the battery or fuse 4 Never connect unit to AC or DC powered circuits when the range switch is set to resistance diode check or con...

Page 3: ...utoranging on Frequency Polarity Automatic minus sign indicates for negative polarity Measuring Rate 2 5 times second Input Impedance 10 M DCV ACV Operation Temp 0 to 45 C Storage Temp 15 to 50 C Fuse...

Page 4: ...C 400mV ranges 1000VDC 750 VAC 4 40 400 1000 750V ranges Current 0 5A 250 V Fuse for 40m 400mA ranges 10A 600 V Fuse for 10A range Maximum 60 seconds Resistance 500VDC 500VAC Capacitance 3VDC 3VAC rms...

Page 5: ...o not connect to the circuit for more than 60 seconds and wait 10 minutes between 10A meas urements 3 1 PlugtheredtestleadintothemAjackandtheblacktestleadintotheCOM jack If the current being measured...

Page 6: ...to the circuit being measured and disconnect test leads NOTE If changing range switch to or from the 10A position first disconnect power and test leads from the circuit being tested Repeat the above...

Page 7: ...to 7 1 Plug the red test lead into the V jack and the black test lead into the COM jack 7 2 Set the range switch to the setting 7 3 Connect the probes to the device you want to test Note the meter rea...

Page 8: ...t the capacitor leads are inserted into opposing sockets 10 3 Read the displayed capacitor value 11 INDUCTANCE MEASUREMENT 11 1 SettherangeswitchtothedesiredHInductancesetting Ifyouareunsure of the va...

Page 9: ...connectorandreplacewithanew9Vbattery 13 5 Replace the cover and cover screws 14 FUSE REPLACEMENT WARNING Disconnect both test leads from any equipment before removing back cover Do not use the meter w...

Page 10: ...xplana tion of the defect to In Canada Circuit Test Electronics A Division of R P Electronic Components Ltd 2060 Rosser Ave Burnaby BC V5C 5Y1 Any product which has been subjected to misuse or acciden...

Reviews: